Literature DB >> 23127072

Bidirectional local distance measure for comparing segmentations.

Hak Soo Kim1, Samuel B Park, Simon S Lo, James I Monroe, Jason W Sohn.   

Abstract

PURPOSE: To accurately quantify the local difference between two contour surfaces in two- or three-dimensional space, a new, robust point-to-surface distance measure is developed.
METHODS: To evaluate and visualize the local surface differences, point-to-surface distance measures have been utilized. However, previously well-known point-to-surface distance measures have critical shortfalls. Previous distance measures termed "normal distance (ND)," "radial distance," or "minimum distance (MD)" can report erroneous results at certain points where the surfaces under comparison meet certain conditions. These skewed results are due to the monodirectional characteristics of these methods. ComGrad distance was also proposed to overcome asymmetric characteristics of previous point-to-surface distance measures, but their critical incapability of dealing with a fold or concave contours. In this regard, a new distance measure termed the bidirectional local distance (BLD) is proposed which minimizes errors of the previous methods by taking into account the bidirectional characteristics with the forward and backward directions. BLD measure works through three steps which calculate the maximum value between the forward minimum distance (FMinD) and the backward maximum distance (BMaxD) at each point. The first step calculates the FMinD as the minimum distance to the test surface from a point, p(ref) on the reference surface. The second step involves calculating the minimum distances at every point on the test surface to the reference surface. During the last step, the BMaxD is calculated as the maximum distance among the minimum distances found at p(ref) on the reference surface. Tests are performed on two- and three-dimensional artificial contour sets in comparison to MD and ND measure techniques. Three-dimensional tests performed on actual liver and head-and-neck cancer patients.
RESULTS: The proposed BLD measure provides local distances between segmentations, even in situations where ND, MD, or ComGrad measures fail. In particular, the standard deviation measure is not distorted at certain geometries where ND, MD, and ComGrad measures report skewed results.
CONCLUSIONS: The proposed measure provides more reliable statistics on contour comparisons. From the statistics, specific local and global distances can be extracted. Bidirectional local distance is a reliable distance measure in comparing two- or three-dimensional organ segmentations.

Entities:  

Mesh:

Year:  2012        PMID: 23127072      PMCID: PMC4108711          DOI: 10.1118/1.4754802

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Improved modelling of ultrasound contrast agent diminution for blood perfusion analysis.

Authors:  Christian Kier; Karsten Meyer-Wiethe; Günter Seidel; Alfred Mertins
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

2.  Spatially weighted mutual information image registration for image guided radiation therapy.

Authors:  Samuel B Park; Frank C Rhee; James I Monroe; Jason W Sohn
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

3.  Evaluation of an atlas-based automatic segmentation software for the delineation of brain organs at risk in a radiation therapy clinical context.

Authors:  Aurélie Isambert; Frédéric Dhermain; François Bidault; Olivier Commowick; Pierre-Yves Bondiau; Grégoire Malandain; Dimitri Lefkopoulos
Journal:  Radiother Oncol       Date:  2007-12-26       Impact factor: 6.280

4.  A novel method for comparing 3D target volume delineations in radiotherapy.

Authors:  R W van der Put; B W Raaymakers; E M Kerkhof; M van Vulpen; J J W Lagendijk
Journal:  Phys Med Biol       Date:  2008-04-01       Impact factor: 3.609

5.  Target Contour Testing/Instructional Computer Software (TaCTICS): A Novel Training and Evaluation Platform for Radiotherapy Target Delineation.

Authors:  Jayashree Kalpathy-Cramer; Clifton David Fuller
Journal:  AMIA Annu Symp Proc       Date:  2010-11-13

6.  Segmentation of echocardiographic images using mathematical morphology.

Authors:  J W Klingler; C L Vaughan; T D Fraker; L T Andrews
Journal:  IEEE Trans Biomed Eng       Date:  1988-11       Impact factor: 4.538

7.  Dosimetric evaluation of automatic segmentation for adaptive IMRT for head-and-neck cancer.

Authors:  Stuart Y Tsuji; Andrew Hwang; Vivian Weinberg; Sue S Yom; Jeanne M Quivey; Ping Xia
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-16       Impact factor: 7.038

8.  Development of a population-based model of surface segmentation uncertainties for uncertainty-weighted deformable image registrations.

Authors:  Jian Wu; Martin J Murphy; Elisabeth Weiss; William C Sleeman; Jeffrey Williamson
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

9.  Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy.

Authors:  Kirsten E I Deurloo; Roel J H M Steenbakkers; Lambert J Zijp; Josien A de Bois; Peter J C M Nowak; Coen R N Rasch; Marcel van Herk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-01-01       Impact factor: 7.038

10.  Variability of target and normal structure delineation for breast cancer radiotherapy: an RTOG Multi-Institutional and Multiobserver Study.

Authors:  X Allen Li; An Tai; Douglas W Arthur; Thomas A Buchholz; Shannon Macdonald; Lawrence B Marks; Jean M Moran; Lori J Pierce; Rachel Rabinovitch; Alphonse Taghian; Frank Vicini; Wendy Woodward; Julia R White
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-01       Impact factor: 7.038

View more
  15 in total

1.  Discontinuity Preserving Liver MR Registration with 3D Active Contour Motion Segmentation.

Authors:  Dongxiao Li; Wenxiong Zhong; Kofi M Deh; Thanh Nguyen; Martin R Prince; Yi Wang; Pascal Spincemaille
Journal:  IEEE Trans Biomed Eng       Date:  2018-11-12       Impact factor: 4.538

2.  Variabilities of Magnetic Resonance Imaging-, Computed Tomography-, and Positron Emission Tomography-Computed Tomography-Based Tumor and Lymph Node Delineations for Lung Cancer Radiation Therapy Planning.

Authors:  Kishor Karki; Siddharth Saraiya; Geoffrey D Hugo; Nitai Mukhopadhyay; Nuzhat Jan; Jessica Schuster; Matthew Schutzer; Lester Fahrner; Robert Groves; Kathryn M Olsen; John C Ford; Elisabeth Weiss
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-05-06       Impact factor: 7.038

3.  Characterization and correction of intraoperative soft tissue deformation in image-guided laparoscopic liver surgery.

Authors:  Jon S Heiselman; Logan W Clements; Jarrod A Collins; Jared A Weis; Amber L Simpson; Sunil K Geevarghese; T Peter Kingham; William R Jarnagin; Michael I Miga
Journal:  J Med Imaging (Bellingham)       Date:  2017-12-14

4.  LinSEM: Linearizing segmentation evaluation metrics for medical images.

Authors:  Jieyu Li; Jayaram K Udupa; Yubing Tong; Lisheng Wang; Drew A Torigian
Journal:  Med Image Anal       Date:  2019-11-09       Impact factor: 8.545

5.  A three-dimensional computational analysis of magnetic resonance images characterizes the biological aggressiveness in malignant brain tumours.

Authors:  J Pérez-Beteta; A Martínez-González; V M Pérez-García
Journal:  J R Soc Interface       Date:  2018-12-21       Impact factor: 4.118

6.  Statistical framework for validation without ground truth of choroidal thickness changes detection.

Authors:  Tiziano Ronchetti; Christoph Jud; Peter M Maloca; Selim Orgül; Alina T Giger; Christoph Meier; Hendrik P N Scholl; Rachel Ka Man Chun; Quan Liu; Chi-Ho To; Boris Považay; Philippe C Cattin
Journal:  PLoS One       Date:  2019-06-28       Impact factor: 3.240

7.  Image-based data mining applies to data collected from children.

Authors:  Lydia J Wilson; Abigail Bryce-Atkinson; Andrew Green; Yimei Li; Thomas E Merchant; Marcel van Herk; Eliana Vasquez Osorio; Austin M Faught; Marianne C Aznar
Journal:  Phys Med       Date:  2022-05-21       Impact factor: 3.119

8.  A pilot in silico modeling-based study of the pathological effects on the biomechanical function of tricuspid valves.

Authors:  Devin W Laurence; Emily L Johnson; Ming-Chen Hsu; Ryan Baumwart; Arshid Mir; Harold M Burkhart; Gerhard A Holzapfel; Yi Wu; Chung-Hao Lee
Journal:  Int J Numer Method Biomed Eng       Date:  2020-05-08       Impact factor: 2.747

9.  Development of CBCT-based prostate setup correction strategies and impact of rectal distension.

Authors:  Christine Boydev; Abdelmalik Taleb-Ahmed; Foued Derraz; Laurent Peyrodie; Jean-Philippe Thiran; David Pasquier
Journal:  Radiat Oncol       Date:  2015-04-10       Impact factor: 3.481

10.  Does setup on rectal wall improve rectal cancer boost radiotherapy?

Authors:  Jean-Paul J E Kleijnen; Bram van Asselen; Martijn Intven; Johannes P M Burbach; Marielle E P Philippens; Jan J W Lagendijk; Bas W Raaymakers
Journal:  Radiat Oncol       Date:  2018-04-04       Impact factor: 3.481

View more