Literature DB >> 18374231

Four-dimensional computed tomography scan analysis of tumor and organ motion at varying levels of abdominal compression during stereotactic treatment of lung and liver.

John H Heinzerling1, John F Anderson, Lech Papiez, Thomas Boike, Stanley Chien, Geoffrey Zhang, Ramzi Abdulrahman, Robert Timmerman.   

Abstract

PURPOSE: To investigate the effectiveness of different abdominal compression levels on tumor and organ motion during stereotactic body radiotherapy of lower lobe lung and liver tumors using four-dimensional (4D)-CT scan analysis. METHODS AND MATERIALS: Three 4D-CT scans were acquired for 10 patients first using with no compression and then compared with two different levels of abdominal compression. The position of the tumor and various organs were defined at the peak inspiratory and expiratory phases and compared to determine the maximum motion.
RESULTS: Mean (+/-SD) medium compression force (MC) and high compression force (HC) were 47.6 +/- 16.0 N and 90.7 +/- 27.1 N, respectively. Mean overall tumor motion was 13.6 mm (2sigma [2 sigma] 11.5-15.6), 8.3 mm (2sigma 6.0-10.5), and 7.2 mm (2sigma 5.4-9.0) for no compression, MC, and HC, respectively. A significant difference in the control of both superior-inferior (SI) and overall motion of tumors was seen with the application of MC and HC when compared with no compression (p < 0.0001 for both). High compression force improved SI and overall tumor motion compared with MC, but this was only significant for SI motion (p = 0.04 and p = 0.06). Significant control of organ motion was only seen in the pancreas (p = 0.01).
CONCLUSIONS: Four-dimensional CT shows significant control of both lower lobe lung and liver tumors using abdominal compression. High levels of compression improve SI tumor motion when compared with MC.

Entities:  

Mesh:

Year:  2008        PMID: 18374231     DOI: 10.1016/j.ijrobp.2007.12.023

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  52 in total

1.  In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system.

Authors:  Muyinatu A Lediju Bell; H Tutkun Sen; Iulian Iordachita; Peter Kazanzides; John Wong
Journal:  J Med Imaging (Bellingham)       Date:  2014-07-23

Review 2.  kV cone-beam CT-based IGRT: a clinical review.

Authors:  Judit Boda-Heggemann; Frank Lohr; Frederik Wenz; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

3.  Evaluation of reproducibility of tumor repositioning during multiple breathing cycles for liver stereotactic body radiotherapy treatment.

Authors:  Ludovic Bedos; Olivier Riou; Norbert Aillères; Antoine Braccini; Jessica Molinier; Carmen Llacer Moscardo; David Azria; Pascal Fenoglietto
Journal:  Rep Pract Oncol Radiother       Date:  2016-11-12

4.  Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology.

Authors:  Edward D Brandner; Indrin J Chetty; Tawfik G Giaddui; Ying Xiao; M Saiful Huq
Journal:  Med Phys       Date:  2017-04-20       Impact factor: 4.071

5.  Forces on cardiac implantable electronic devices during remote magnetic navigation.

Authors:  C Jilek; C Lennerz; B Stracke; H Badran; V Semmler; T Reents; S Ammar; S Fichtner; B Haller; G Hessling; I Deisenhofer; C Kolb
Journal:  Clin Res Cardiol       Date:  2012-09-29       Impact factor: 5.460

Review 6.  Radiotherapy for liver tumors.

Authors:  Florence K Keane; Shyam K Tanguturi; Andrew X Zhu; Laura A Dawson; Theodore S Hong
Journal:  Hepat Oncol       Date:  2015-04-20

Review 7.  Liver-Directed Radiotherapy for Hepatocellular Carcinoma.

Authors:  Florence K Keane; Jennifer Y Wo; Andrew X Zhu; Theodore S Hong
Journal:  Liver Cancer       Date:  2016-05-10       Impact factor: 11.740

Review 8.  Radiation therapy for liver tumors: ready for inclusion in guidelines?

Authors:  Shyam K Tanguturi; Jennifer Y Wo; Andrew X Zhu; Laura A Dawson; Theodore S Hong
Journal:  Oncologist       Date:  2014-07-07

9.  Interobserver variability of patient positioning using four different CT datasets for image registration in lung stereotactic body radiotherapy.

Authors:  Markus Oechsner; Barbara Chizzali; Michal Devecka; Stefan Münch; Stephanie Elisabeth Combs; Jan Jakob Wilkens; Marciana Nona Duma
Journal:  Strahlenther Onkol       Date:  2017-07-19       Impact factor: 3.621

Review 10.  Solutions that enable ablative radiotherapy for large liver tumors: Fractionated dose painting, simultaneous integrated protection, motion management, and computed tomography image guidance.

Authors:  Christopher H Crane; Eugene J Koay
Journal:  Cancer       Date:  2016-03-07       Impact factor: 6.860

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.