Literature DB >> 18371638

Measurement of sodium ion concentration in undiluted urine with cation-selective polymeric membrane electrodes after the removal of interfering compounds.

Feyisayo Phillips1, Kim Kaczor, Neel Gandhi, Bradford D Pendley, Robert K Danish, Michael R Neuman, Blanka Tóth, Viola Horváth, Ernö Lindner.   

Abstract

The measurement of sodium ion concentration in urine can provide diagnostic information and guide therapy. Unfortunately, neutral-carrier-based ion-selective electrodes show a large positive drift and loss in selectivity in undiluted urine. The extraction of electrically neutral lipids from the urine into the sensing membrane was suggested as the main source of the drift, loss of selectivity and the consequent incorrect concentration readings. In this work, (i) solvent-solvent extraction, (ii) membrane-immobilized solvent extraction and (iii) solid phase extraction were used to remove interfering compounds from urine samples. The "cleaned" urine samples were subsequently analyzed using a calixarene (sodium ionophore X)-based, solid-contact, sodium-selective electrode in a flow-through manifold. The solid-contact sodium sensors had excellent stability in cleaned urine and an acceptable bias compared to commercial clinical analyzers.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18371638      PMCID: PMC2151744          DOI: 10.1016/j.talanta.2007.06.011

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  9 in total

1.  Influence of natural, electrically neutral lipids on the potentiometric responses of cation-selective polymeric membrane electrodes.

Authors:  P Bühlmann; M Hayakawa; T Ohshiro; S Amemiya; Y Umezawa
Journal:  Anal Chem       Date:  2001-07-15       Impact factor: 6.986

2.  A chronoamperometric method to estimate changes in the membrane composition of ion-selective membranes.

Authors:  B D Pendley; R E Gyurcsányi; R P Buck; E Lindner
Journal:  Anal Chem       Date:  2001-10-01       Impact factor: 6.986

3.  Determination of Na+ and K+ in urine with ion-selective electrodes in an automated analyzer.

Authors:  A Pelleg; G B Levy
Journal:  Clin Chem       Date:  1975-10       Impact factor: 8.327

4.  A polypyrrole-based solid-contact Pb(2+)-selective PVC-membrane electrode with a nanomolar detection limit.

Authors:  Jolanda Sutter; Ernö Lindner; Robert E Gyurcsányi; Ernö Pretsch
Journal:  Anal Bioanal Chem       Date:  2004-08-07       Impact factor: 4.142

5.  Effects of hyperlipidemia on plasma sodium, potassium, and chloride measurements by an indirect ion-selective electrode measuring system.

Authors:  Goce Dimeski; Peter Mollee; Andrew Carter
Journal:  Clin Chem       Date:  2006-01       Impact factor: 8.327

6.  Fluorous bulk membranes for potentiometric sensors with wide selectivity ranges: observation of exceptionally strong ion pair formation.

Authors:  Paul G Boswell; Philippe Bühlmann
Journal:  J Am Chem Soc       Date:  2005-06-29       Impact factor: 15.419

7.  Solid contact potentiometric sensors for trace level measurements.

Authors:  Karin Y Chumbimuni-Torres; Nastassia Rubinova; Aleksandar Radu; Lauro T Kubota; Eric Bakker
Journal:  Anal Chem       Date:  2006-02-15       Impact factor: 6.986

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

9.  Microfabricated ISEs: critical comparison of inherently conducting polymer and hydrogel based inner contacts.

Authors:  Róbert E Gyurcsányi; Neeraja Rangisetty; Sarah Clifton; Bradford D Pendley; Erno Lindner
Journal:  Talanta       Date:  2004-05-10       Impact factor: 6.057

  9 in total
  1 in total

1.  Beneficial Impact of Pork Dry-Cured Ham Consumption on Blood Pressure and Cardiometabolic Markers in Individuals with Cardiovascular Risk.

Authors:  Silvia Montoro-García; Ángeles Velasco-Soria; Leticia Mora; Carmen Carazo-Díaz; David Prieto-Merino; Antonio Avellaneda; Domingo Miranzo; Teresa Casas-Pina; Fidel Toldrá; José Abellán-Alemán
Journal:  Nutrients       Date:  2022-01-11       Impact factor: 5.717

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.