Literature DB >> 18371489

Noninvasively determined radial dP/dt is a predictor of mortality in patients with heart failure.

Jean-Michel Tartière1, Jean-Yves Tabet, Damien Logeart, Lamia Tartière-Kesri, Florence Beauvais, Christophe Chavelas, Alain Cohen Solal.   

Abstract

BACKGROUND: The left ventricular (LV) developed pressure is a marker of contractility, associated with a poor prognosis during systolic heart failure. The maximal first derivative or slope of the radial pulse wave (Rad dP/dt) has been proposed as a marker of LV systolic function. This study sought to assess the prognostic value of the baseline dP/dt of the radial pulse in patients with heart failure.
METHODS: The Rad dP/dt was noninvasively measured by applanation tonometry, and its effect on mortality was analyzed by using multivariate Cox regression models. We studied 310 consecutive patients. Mean follow-up was 327 +/- 187 days, and 64 patients died or were transplanted during this period.
RESULTS: Death or transplantation was associated with New York Heart Association class III or IV, low systolic or mean blood pressure, low LV ejection fraction, and low Rad dP/dt (634.6 +/- 373.3 vs 730.2 +/- 367.4 mm Hg/s for patients who survived without transplantation, P < .02). A Rad dP/dt <440 mm Hg/s was associated with death or transplantation before and after adjustment for confounding variables (OR [95% CI] 2.19 [1.33-3.58] and 2.88 [1.29-6.38], respectively, P < .01 for both). This relationship was independent of pulse pressure and no significant interaction was found between the Rad dP/dt and the pulse pressure.
CONCLUSION: This study demonstrates, for the first time, that the Rad dP/dt, proposed as a noninvasive peripheral marker of LV systolic function, is an independent predictor of death or transplantation in patients with HF regardless of LV ejection fraction.

Entities:  

Mesh:

Year:  2008        PMID: 18371489     DOI: 10.1016/j.ahj.2007.11.030

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  4 in total

1.  Assessment of left ventricular function by pulse wave analysis in critically ill patients.

Authors:  Sabino Scolletta; Laurent Bodson; Katia Donadello; Fabio S Taccone; Alessandro Devigili; Jean-Louis Vincent; Daniel De Backer
Journal:  Intensive Care Med       Date:  2013-03-09       Impact factor: 17.440

2.  Inhaled ambient-level traffic-derived particulates decrease cardiac vagal influence and baroreflexes and increase arrhythmia in a rat model of metabolic syndrome.

Authors:  Alex P Carll; Samir M Crespo; Mauricio S Filho; Douglas H Zati; Brent A Coull; Edgar A Diaz; Rodrigo D Raimundo; Thomas N G Jaeger; Ana Laura Ricci-Vitor; Vasileios Papapostolou; Joy E Lawrence; David M Garner; Brigham S Perry; Jack R Harkema; John J Godleski
Journal:  Part Fibre Toxicol       Date:  2017-05-25       Impact factor: 9.400

3.  The role of the maximal first derivative of the radial pulse wave (Rad dP/dtmax) in monitoring cardiac function.

Authors:  Hao Guo; Jing Zhou; Zhi Wang; Li-Kun Liu; Shu-Zhen Yu; Hong-Wei Cai
Journal:  J Thorac Dis       Date:  2020-05       Impact factor: 2.895

4.  Components of Oranta-AO software expert system for innovative application of blood pressure monitors.

Authors:  Dmytro Vakulenko; Lyudmyla Vakulenko; Hryhoriy Zaspa; Serhii Lupenko; Petro Stetsyuk; Viktor Stovba
Journal:  J Reliab Intell Environ       Date:  2022-09-21
  4 in total