Literature DB >> 18367796

Equivalent dose and effective dose from stray radiation during passively scattered proton radiotherapy for prostate cancer.

Jonas Fontenot1, Phillip Taddei, Yuanshui Zheng, Dragan Mirkovic, Thomas Jordan, Wayne Newhauser.   

Abstract

Proton therapy reduces the integral therapeutic dose required for local control in prostate patients compared to intensity-modulated radiotherapy. One proposed benefit of this reduction is an associated decrease in the incidence of radiogenic secondary cancers. However, patients are also exposed to stray radiation during the course of treatment. The purpose of this study was to quantify the stray radiation dose received by patients during proton therapy for prostate cancer. Using a Monte Carlo model of a proton therapy nozzle and a computerized anthropomorphic phantom, we determined that the effective dose from stray radiation per therapeutic dose (E/D) for a typical prostate patient was approximately 5.5 mSv Gy(-1). Sensitivity analysis revealed that E/D varied by +/-30% over the interval of treatment parameter values used for proton therapy of the prostate. Equivalent doses per therapeutic dose (HT/D) in specific organs at risk were found to decrease with distance from the isocenter, with a maximum of 12 mSv Gy(-1) in the organ closest to the treatment volume (bladder) and 1.9 mSv Gy(-1) in the furthest (esophagus). Neutrons created in the nozzle predominated effective dose, though neutrons created in the patient contributed substantially to the equivalent dose in organs near the proton field. Photons contributed less than 15% to equivalent doses.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18367796     DOI: 10.1088/0031-9155/53/6/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  28 in total

1.  Estimate of the uncertainties in the relative risk of secondary malignant neoplasms following proton therapy and intensity-modulated photon therapy.

Authors:  Jonas D Fontenot; Charles Bloch; David Followill; Uwe Titt; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

2.  Predicted risks of second malignant neoplasm incidence and mortality due to secondary neutrons in a girl and boy receiving proton craniospinal irradiation.

Authors:  Phillip J Taddei; Anita Mahajan; Dragan Mirkovic; Rui Zhang; Annelise Giebeler; David Kornguth; Mark Harvey; Shiao Woo; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

3.  Risk of second malignant neoplasm following proton versus intensity-modulated photon radiotherapies for hepatocellular carcinoma.

Authors:  Phillip J Taddei; Rebecca M Howell; Sunil Krishnan; Sarah B Scarboro; Dragan Mirkovic; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

4.  An analytic model of neutron ambient dose equivalent and equivalent dose for proton radiotherapy.

Authors:  Rui Zhang; Angélica Pérez-Andújar; Jonas D Fontenot; Phillip J Taddei; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

5.  Assessment of out-of-field absorbed dose and equivalent dose in proton fields.

Authors:  Ben Clasie; Andrew Wroe; Hanne Kooy; Nicolas Depauw; Jay Flanz; Harald Paganetti; Anatoly Rosenfeld
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

6.  Contribution to Neutron Fluence and Neutron Absorbed Dose from Double Scattering Proton Therapy System Components.

Authors:  A Pérez-Andújar; W D Newhauser; P M Deluca
Journal:  Nucl Technol       Date:  2009-01-01

Review 7.  Assessment of the risk for developing a second malignancy from scattered and secondary radiation in radiation therapy.

Authors:  Harald Paganetti
Journal:  Health Phys       Date:  2012-11       Impact factor: 1.316

8.  ANALYTICAL MODEL TO ESTIMATE EQUIVALENT DOSE FROM INTERNAL NEUTRONS IN PROTON THERAPY OF CHILDREN WITH INTRACRANIAL TUMORS.

Authors:  Kyle J Gallagher; Phillip J Taddei
Journal:  Radiat Prot Dosimetry       Date:  2019-06-01       Impact factor: 0.972

9.  Neutron production from beam-modifying devices in a modern double scattering proton therapy beam delivery system.

Authors:  Angélica Pérez-Andújar; Wayne D Newhauser; Paul M Deluca
Journal:  Phys Med Biol       Date:  2009-01-16       Impact factor: 3.609

10.  Reduction of the secondary neutron dose in passively scattered proton radiotherapy, using an optimized pre-collimator/collimator.

Authors:  David J Brenner; Carl D Elliston; Eric J Hall; Harald Paganetti
Journal:  Phys Med Biol       Date:  2009-09-24       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.