Literature DB >> 18360511

Near-field artifact reduction in planar coded aperture imaging.

R Accorsi1, R C Lanza.   

Abstract

Coded apertures for imaging problems are typically based on arrays having perfect cross-correlation properties. These arrays, however, guarantee a perfect point-spread function in far-field applications only. When these arrays are used in the near-field, artifacts arise. We present a mathematical derivation capable of predicting the shape of such artifacts. The theory shows that methods used in the past to compensate for the effects of background nonuniformities in far-field problems are also effective in reducing near-field artifacts. The case study of a nuclear medicine problem is presented to show good agreement of simulation and experimental results with mathematical predictions.

Year:  2001        PMID: 18360511     DOI: 10.1364/ao.40.004697

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  7 in total

1.  A novel three-dimensional image reconstruction method for near-field coded aperture single photon emission computerized tomography.

Authors:  Zhiping Mu; Baoming Hong; Shimin Li; Yi-Hwa Liu
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

2.  Recent advances in BazookaSPECT: Real-time data processing and the development of a gamma-ray microscope.

Authors:  Brian W Miller; Harrison H Barrett; Lars R Furenlid; H Bradford Barber; Robert J Hunter
Journal:  Nucl Instrum Methods Phys Res A       Date:  2008-06-11       Impact factor: 1.455

3.  Optimization of coded aperture radioscintigraphy for sentinel lymph node mapping.

Authors:  Hirofumi Fujii; John D Idoine; Sylvain Gioux; Roberto Accorsi; David R Slochower; Richard C Lanza; John V Frangioni
Journal:  Mol Imaging Biol       Date:  2012-04       Impact factor: 3.488

4.  High resolution and sensitivity gamma camera with active septa. A first Monte Carlo study.

Authors:  Victor Ilisie; Laura Moliner; Sandra Oliver; Filomeno Sánchez; Antonio J González; Michael Seimetz; Maria J Rodríguez-Álvarez; Jose Maria Benlloch
Journal:  Sci Rep       Date:  2019-12-05       Impact factor: 4.379

5.  Gamma Camera Imaging with Rotating Multi-Pinhole Collimator. A Monte Carlo Feasibility Study.

Authors:  Victor Ilisie; Laura Moliner; Constantino Morera; Johan Nuyts; José María Benlloch
Journal:  Sensors (Basel)       Date:  2021-05-12       Impact factor: 3.576

6.  SPECT Imaging of 2-D and 3-D Distributed Sources with Near-Field Coded Aperture Collimation: Computer Simulation and Real Data Validation.

Authors:  Zhiping Mu; Lawrence W Dobrucki; Yi-Hwa Liu
Journal:  J Med Biol Eng       Date:  2016-02-18       Impact factor: 1.553

7.  Gamma Radiation Imaging System via Variable and Time-Multiplexed Pinhole Arrays.

Authors:  Ariel Schwarz; Amir Shemer; Yossef Danan; Rachel Bar-Shalom; Hemy Avraham; Alex Zlotnik; Zeev Zalevsky
Journal:  Sensors (Basel)       Date:  2020-05-26       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.