Literature DB >> 21567254

Optimization of coded aperture radioscintigraphy for sentinel lymph node mapping.

Hirofumi Fujii1, John D Idoine, Sylvain Gioux, Roberto Accorsi, David R Slochower, Richard C Lanza, John V Frangioni.   

Abstract

PURPOSE: Radioscintigraphic imaging during sentinel lymph node (SLN) mapping could potentially improve localization; however, parallel-hole collimators have certain limitations. In this study, we explored the use of coded aperture (CA) collimators. PROCEDURES: Equations were derived for the six major dependent variables of CA collimators (i.e., masks) as a function of the ten major independent variables, and an optimized mask was fabricated. After validation, dual-modality CA and near-infrared (NIR) fluorescence SLN mapping were performed in pigs.
RESULTS: Mask optimization required the judicious balance of competing dependent variables, resulting in sensitivity of 0.35%, XY resolution of 2.0 mm, and Z resolution of 4.2 mm at an 11.5-cm field of view. The findings in pigs suggested that NIR fluorescence imaging and CA radioscintigraphy could be complementary, but present difficult technical challenges.
CONCLUSIONS: This study lays the foundation for using CA collimation for SLN mapping, and also exposes several problems that require further investigation.

Entities:  

Mesh:

Year:  2012        PMID: 21567254      PMCID: PMC3156935          DOI: 10.1007/s11307-011-0494-2

Source DB:  PubMed          Journal:  Mol Imaging Biol        ISSN: 1536-1632            Impact factor:   3.488


  13 in total

1.  Coded aperture nuclear scintigraphy: a novel small animal imaging technique.

Authors:  Dawid Schellingerhout; Roberto Accorsi; Umar Mahmood; John Idoine; Richard C Lanza; Ralph Weissleder
Journal:  Mol Imaging       Date:  2002-10       Impact factor: 4.488

2.  Coded aperture imaging with uniformly redundant arrays.

Authors:  E E Fenimore; T M Cannon
Journal:  Appl Opt       Date:  1978-02-01       Impact factor: 1.980

3.  Tomographic thyroid scintigraphy: comparison with standard pinhole imaging: concise communication.

Authors:  W W Resinger; E A Rose; J W Keyes; K F Koral; W L Rogers; T J Brady; R C Kline; J C Sisson; J H Thrall
Journal:  J Nucl Med       Date:  1981-07       Impact factor: 10.057

4.  Coded-aperture imaging of the heart.

Authors:  W L Rogers; K F Koral; R Mayans; P F Leonard; J H Thrall; T J Brady; J W Keyes
Journal:  J Nucl Med       Date:  1980-04       Impact factor: 10.057

5.  Organic alternatives to quantum dots for intraoperative near-infrared fluorescent sentinel lymph node mapping.

Authors:  Shunsuke Ohnishi; Stephen J Lomnes; Rita G Laurence; Andrew Gogbashian; Giuliano Mariani; John V Frangioni
Journal:  Mol Imaging       Date:  2005 Jul-Sep       Impact factor: 4.488

Review 6.  Sentinel nodes of malignancies originating in the alimentary tract.

Authors:  Hirofumi Fujii; Yuko Kitagawa; Masaki Kitajima; Atsushi Kubo
Journal:  Ann Nucl Med       Date:  2004-02       Impact factor: 2.668

7.  Sentinel lymph node mapping of the gastrointestinal tract by using invisible light.

Authors:  Edward G Soltesz; Sungjee Kim; Sang-Wook Kim; Rita G Laurence; Alec M De Grand; Cherie P Parungo; Lawrence H Cohn; Moungi G Bawendi; John V Frangioni
Journal:  Ann Surg Oncol       Date:  2006-01-31       Impact factor: 5.344

8.  Tissue-like phantoms for near-infrared fluorescence imaging system assessment and the training of surgeons.

Authors:  Alec M De Grand; Stephen J Lomnes; Deborah S Lee; Matthew Pietrzykowski; Shunsuke Ohnishi; Timothy G Morgan; Andrew Gogbashian; Rita G Laurence; John V Frangioni
Journal:  J Biomed Opt       Date:  2006 Jan-Feb       Impact factor: 3.170

9.  Sub-millimeter technetium-99m calibration sources.

Authors:  Jeffrey R English; Roberto Accorsi; John D Idoine; J Anthony Parker; Jürgen T Renze; Richard C Lanza; John V Frangioni
Journal:  Mol Imaging Biol       Date:  2002-10       Impact factor: 3.488

10.  An operational near-infrared fluorescence imaging system prototype for large animal surgery.

Authors:  A M De Grand; J V Frangioni
Journal:  Technol Cancer Res Treat       Date:  2003-12
View more
  2 in total

1.  High resolution and sensitivity gamma camera with active septa. A first Monte Carlo study.

Authors:  Victor Ilisie; Laura Moliner; Sandra Oliver; Filomeno Sánchez; Antonio J González; Michael Seimetz; Maria J Rodríguez-Álvarez; Jose Maria Benlloch
Journal:  Sci Rep       Date:  2019-12-05       Impact factor: 4.379

2.  Gamma Camera Imaging with Rotating Multi-Pinhole Collimator. A Monte Carlo Feasibility Study.

Authors:  Victor Ilisie; Laura Moliner; Constantino Morera; Johan Nuyts; José María Benlloch
Journal:  Sensors (Basel)       Date:  2021-05-12       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.