Polypropylene slings are monofilament and multifilament meshes. Their features can impact clinical outcomes. We analyzed tissue reaction, inflammation, and the density of collagen fibers elicited by polypropylene meshes in the subcutaneous tissue of female rats. Thirty female Wistar rats underwent the implantation of 8x4-mm polypropylene meshes (two monofilamentar and two multifilamentar). The rats were killed at 7, 60, and 120 days after implant. Stereology was used to analyze the collagen fiber density. Acute inflammation was more intense in the early post-implant period (p=0.006), except for intravaginal slingplasty (p=0.342). Lymphoplasmocytic reaction was more intense in multifilament samples, even after 60 days (p<0.001) and 120 days (p=0.001). The stereological analysis showed significant differences between mono- and multifilament meshes, considering that monofilament meshes induced more collagen deposition and a greater density of collagen fibers (p<0.001). Multifilament meshes produced a more granulomatous reaction. The collagen fiber density was greater in monofilament meshes, which induced more favorable biocompatibility assessed objectively.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18351281     DOI: 10.1007/s00192-008-0582-2

Source DB:  PubMed          Journal:  Int Urogynecol J Pelvic Floor Dysfunct


  12 in total

1.  The standardisation of terminology of lower urinary tract function: report from the Standardisation Sub-committee of the International Continence Society.

Authors:  Paul Abrams; Linda Cardozo; Magnus Fall; Derek Griffiths; Peter Rosier; Ulf Ulmsten; Philip van Kerrebroeck; Arne Victor; Alan Wein
Journal:  Neurourol Urodyn       Date:  2002       Impact factor: 2.696

2.  Erosion, defective healing and extrusion after tension-free urethropexy for the treatment of stress urinary incontinence.

Authors:  Karin Glavind; Pia Sander
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2004-02-14

Review 3.  Understanding wound fluid and the phases of healing.

Authors:  Darlene Hanson; Diane Langemo; Pat Thompson; Julie Anderson; Susan Hunter
Journal:  Adv Skin Wound Care       Date:  2005-09       Impact factor: 2.347

4.  High incidence of vaginal mesh extrusion using the intravaginal slingplasty sling.

Authors:  Andrew L Siegel; Michelle Kim; Martin Goldstein; Stuart Levey; Pedram Ilbeigi
Journal:  J Urol       Date:  2005-10       Impact factor: 7.450

5.  Multifilament polypropylene mesh for urinary incontinence: 10 cases of infections requiring removal of the sling.

Authors:  Abdolreza Bafghi; Emmanuel I Benizri; Cynthia Trastour; Eric J Benizri; Jean-François Michiels; André Bongain
Journal:  BJOG       Date:  2005-03       Impact factor: 6.531

6.  A stereological analysis of fibrosis and inflammatory reaction induced by four different synthetic slings.

Authors:  Marcelo Thiel; Paulo C Rodrigues Palma; Cássio L Z Riccetto; Miriam Dambros; Nelson R Netto
Journal:  BJU Int       Date:  2005-04       Impact factor: 5.588

7.  Effect of pore size on the peel strength of attachment of fibrous tissue to porous-surfaced implants.

Authors:  J D Bobyn; G J Wilson; D C MacGregor; R M Pilliar; G C Weatherly
Journal:  J Biomed Mater Res       Date:  1982-09

8.  Urethrovaginal fistula--a rare complication after the placement of a suburethral sling (IVS).

Authors:  Christl Reisenauer; Diethelm Wallwiener; Arnulf Stenzl; Franz-Erich Solomayer; Karl-Dietrich Sievert
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2006-05-04

9.  Physical and biological characteristics of the main biomaterials used in pelvic surgery.

Authors:  J L Brun; L Bordenave; F Lefebvre; R Bareille; C Barbié; F Rouais; C H Baquey
Journal:  Biomed Mater Eng       Date:  1992       Impact factor: 1.300

10.  Practical stereological methods for morphometric cytology.

Authors:  E R Weibel; G S Kistler; W F Scherle
Journal:  J Cell Biol       Date:  1966-07       Impact factor: 10.539

View more
  8 in total

1.  Posterior intravaginal slingplasty: efficacy and complications in a continuous series of 118 cases.

Authors:  Stefano Cosma; Mario Preti; Marco Mitidieri; Paolo Petruzzelli; Federica Possavino; Guido Menato
Journal:  Int Urogynecol J       Date:  2011-01-14       Impact factor: 2.894

2.  Tissue response to a new type of biomaterial implanted subcutaneously in rats.

Authors:  Marie Boennelycke; Lise Christensen; Lene Feldskov Nielsen; Hanne Everland; Gunnar Lose
Journal:  Int Urogynecol J       Date:  2010-09-14       Impact factor: 2.894

3.  Gluteo-vaginal fistula: a long-term complication of posterior intravaginal slingplasty.

Authors:  Vernon Sivarajah; Sean O Z Bello; Chu Yiu Yiu; Olatokunbo Oke
Journal:  BMJ Case Rep       Date:  2011-10-28

4.  Highly purified collagen coating enhances tissue adherence and integration properties of monofilament polypropylene meshes.

Authors:  Rodrigo Teixeira Siniscalchi; Marli Melo; Paulo César Rodrigues Palma; Inácio Maria Dal Fabbro; Benedicto de Campos Vidal; Cassio Luiz Zanettini Riccetto
Journal:  Int Urogynecol J       Date:  2013-05-04       Impact factor: 2.894

5.  Effect of platelet-rich plasma on polypropylene meshes implanted in the rabbit vagina: histological analysis.

Authors:  Natália Gomes Parizzi; Oscar Ávila Rubini; Silvio Henrique Maia de Almeida; Lais Caetano Ireno; Roger Mitio Tashiro; Victor Hugo Tolotto de Carvalho
Journal:  Int Braz J Urol       Date:  2017 Jul-Aug       Impact factor: 1.541

6.  A new material to prevent urethral damage after implantation of artificial devices: an experimental study.

Authors:  Salvador Vilar Correia Lima; Marcilio Romero Machado; Flávia Cristina Morone Pinto; Mariana Montenegro de Melo Lira; Amanda Vasconcelos de Albuquerque; Eugênio Soares Lustosa; Jaiurte Gomes Martins da Silva; Olávio Campos
Journal:  Int Braz J Urol       Date:  2017 Mar-Apr       Impact factor: 1.541

7.  Focus on collagen: in vitro systems to study fibrogenesis and antifibrosis state of the art.

Authors:  Clarice Zc Chen; Michael Raghunath
Journal:  Fibrogenesis Tissue Repair       Date:  2009-12-15

8.  Structural differences and architectural features of two different polypropylene slings (TVT-O and I-STOP) have no impact on biocompatibility and tissue reactions.

Authors:  Mikolaj Przydacz; Oussama El Yazami Adli; Wally Mahfouz; Oleg Loutochin; Louis R Bégin; Jacques Corcos
Journal:  Cent European J Urol       Date:  2017-04-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.