Literature DB >> 18345702

Integration of cone-beam CT in stereotactic body radiation therapy.

Fang-Fang Yin1, Zhiheng Wang, Sua Yoo, Q Jackie Wu, John Kirkpatrick, Nicole Larrier, Jeffrey Meyer, Christopher G Willett, Lawrence B Marks.   

Abstract

This report describes the technique and initial experience using cone beam CT (CBCT) for localization of treatment targets in patients undergoing stereotactic body radiation therapy (SBRT). Patients selected for SBRT underwent 3-D or 4-D CT scans in a customized immobilization cradle. GTV, CTV, ITV, and PTV were defined. Intensity-modulated radiation beams, multiple 3-D conformal beams, or dynamic conformal arcs were delivered using a Varian 21EX with 120-leaf MLC. CBCT images were obtained prior to each fraction, and registered to the planning CT by using soft tissue and bony structures to assure accurate isocenter localization. Patients were repositioned for treatment based on the CBCT images. Radiographic images (kV, MV, or CBCT) were taken before and after beam delivery to further assess set-up accuracy. Ten patients with lung, liver, and spine lesions received 29 fractions of treatment using this technique. The prescription doses ranged 1250 approximately 6000 cGy in 1 approximately 5 fractions. Compared to traditional 2-D matching using bony structures, CBCT corrects target deviation from 1 mm to 15 mm, with an average of 5 mm. Comparison of pre-treatment to post-treatment radiographic images demonstrated an average 2 mm deviation (ranging from 0-4 mm). Improved immobilization may enhance positioning accuracy. Typical total "in-room" times for the patients are approximately 1 hour. CBCT-guided SBRT is feasible and enhances setup accuracy using 3-D anatomical information.

Entities:  

Mesh:

Year:  2008        PMID: 18345702     DOI: 10.1177/153303460800700206

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  12 in total

1.  Potential underestimation of the internal target volume (ITV) from free-breathing CBCT.

Authors:  Irina Vergalasova; Jacqueline Maurer; Fang-Fang Yin
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

2.  Feasibility of 3D tracking and adaptation of VMAT based on VMAT-CT.

Authors:  Xiaodong Zhao; Rui Zhang
Journal:  Radiother Oncol       Date:  2020-04-24       Impact factor: 6.280

Review 3.  Image-guided radiotherapy and motion management in lung cancer.

Authors:  S S Korreman
Journal:  Br J Radiol       Date:  2015-05-08       Impact factor: 3.039

4.  A quality assurance procedure to evaluate cone-beam CT image center congruence with the radiation isocenter of a linear accelerator.

Authors:  Weiliang Du; James N Yang; Eric L Chang; Dershan Luo; Mary Frances McAleer; Almon Shiu; Mary K Martel
Journal:  J Appl Clin Med Phys       Date:  2010-07-02       Impact factor: 2.102

5.  Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience.

Authors:  Zheng Chang; James Bowsher; Jing Cai; Sua Yoo; Zhiheng Wang; Justus Adamson; Lei Ren; Fang-Fang Yin
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

6.  Initial experience and clinical comparison of two image guidance methods for SBRT treatment: 4DCT versus respiratory-triggered imaging.

Authors:  Brian Wang; Prema Rassiah-Szegedi; Hui Zhao; Y Jessica Huang; Vikren Sarkar; Martin Szegedi; Kristine E Kokeny; Christopher J Anker; Dennis C Shrieve; Bill J Salter
Journal:  J Appl Clin Med Phys       Date:  2011-01-31       Impact factor: 2.102

7.  Assessment of setup uncertainties for various tumor sites when using daily CBCT for more than 2200 VMAT treatments.

Authors:  Young-Kee Oh; Jong-Geun Baek; Ok-Bae Kim; Jin-Hee Kim
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

8.  Target repositional accuracy and PTV margin verification using three-dimensional cone-beam computed tomography (CBCT) in stereotactic body radiotherapy (SBRT) of lung cancers.

Authors:  Lu Wang; Steven Feigenberg; Jiajian Fan; Lihui Jin; Aruna Turaka; Lili Chen; C-M Charlie Ma
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

9.  Spine Stereotactic Body Radiation Therapy Residual Setup Errors and Intra-Fraction Motion Using the Stereotactic X-Ray Image Guidance Verification System.

Authors:  Kosj Yamoah; Nicholas G Zaorsky; Joshua Siglin; Wenyin Shi; Maria Werner-Wasik; David W Andrews; Adam P Dicker; Voichita Bar-Ad; Haisong Liu
Journal:  Int J Med Phys Clin Eng Radiat Oncol       Date:  2014-02

10.  Characterization and evaluation of 2.5 MV electronic portal imaging for accurate localization of intra- and extracranial stereotactic radiosurgery.

Authors:  Kwang Hyun Song; Karen Chin Snyder; Jinkoo Kim; Haisen Li; Wen Ning; Robert Rusnac; Paul Jackson; James Gordon; Salim M Siddiqui; Indrin J Chetty
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.