AIMS: To compare the respirable dose delivery of the hydrofluroalkane fluticasone propionate (HFA-FP) via an optimally prepared Aerochamber Plus spacer (AP), via a Synchro-Breathe (SB) device, and pMDI Evohaler (EH). METHODS:Seventeen mild to moderate asthmatics completed the study using a randomized, double-blind, double-dummy, three way crossover design. Single doses of placebo or HFA-FP 2.0 mg were administered via the EH, AP, and SB devices. The overnight urinary cortisol : creatinine ratio (OUCC) was measured at baseline and after each dose. RESULTS: Significant suppression of OUCC occurred from baseline with AP and SB but not EH devices (geometric mean fold suppression, 95% CI): AP: 3.18 (2.29, 4.36), P < 0.001; SB: 1.79 (1.31, 2.40), P = 0.001; EH: 1.12 (0.69, 1.44), p = 0.37 (equating to 68%, 45% and 9% falls, respectively). Significant differences in OUCC between devices were as follows: (geometric mean fold difference, 95% CI): AP vs. EH. 2.83 (2.09, 3.82), P < 0.001; AP vs. SB: 1.78 fold (1.21, 2.60), P = 0.003; SB vs. EH: 1.59 (1.09, 2.31), P = 0.013 (equating to 65%, 44% and 37% differences, respectively). CONCLUSIONS: The use of an optimally prepared AP spacer and breath actuated SB device, when compared with pMDI, significantly increased the respirable dose of HFA-FP.
RCT Entities:
AIMS: To compare the respirable dose delivery of the hydrofluroalkane fluticasone propionate (HFA-FP) via an optimally prepared Aerochamber Plus spacer (AP), via a Synchro-Breathe (SB) device, and pMDI Evohaler (EH). METHODS: Seventeen mild to moderate asthmatics completed the study using a randomized, double-blind, double-dummy, three way crossover design. Single doses of placebo or HFA-FP 2.0 mg were administered via the EH, AP, and SB devices. The overnight urinary cortisol : creatinine ratio (OUCC) was measured at baseline and after each dose. RESULTS: Significant suppression of OUCC occurred from baseline with AP and SB but not EH devices (geometric mean fold suppression, 95% CI): AP: 3.18 (2.29, 4.36), P < 0.001; SB: 1.79 (1.31, 2.40), P = 0.001; EH: 1.12 (0.69, 1.44), p = 0.37 (equating to 68%, 45% and 9% falls, respectively). Significant differences in OUCC between devices were as follows: (geometric mean fold difference, 95% CI): AP vs. EH. 2.83 (2.09, 3.82), P < 0.001; AP vs. SB: 1.78 fold (1.21, 2.60), P = 0.003; SB vs. EH: 1.59 (1.09, 2.31), P = 0.013 (equating to 65%, 44% and 37% differences, respectively). CONCLUSIONS: The use of an optimally prepared AP spacer and breath actuated SB device, when compared with pMDI, significantly increased the respirable dose of HFA-FP.
Authors: Mohamed S Al-Moamary; Sami A Alhaider; Abdullah A Alangari; Mohammed O Al Ghobain; Mohammed O Zeitouni; Majdy M Idrees; Abdullah F Alanazi; Adel S Al-Harbi; Abdullah A Yousef; Hassan S Alorainy; Mohamed S Al-Hajjaj Journal: Ann Thorac Med Date: 2019 Jan-Mar Impact factor: 2.219
Authors: Mohamed S Al-Moamary; Sami A Alhaider; Mohamed S Al-Hajjaj; Mohammed O Al-Ghobain; Majdy M Idrees; Mohammed O Zeitouni; Adel S Al-Harbi; Maha M Al Dabbagh; Hussain Al-Matar; Hassan S Alorainy Journal: Ann Thorac Med Date: 2012-10 Impact factor: 2.219
Authors: Mohamed S Al-Moamary; Sami A Alhaider; Majdy M Idrees; Mohammed O Al Ghobain; Mohammed O Zeitouni; Adel S Al-Harbi; Abdullah A Yousef; Hussain Al-Matar; Hassan S Alorainy; Mohamed S Al-Hajjaj Journal: Ann Thorac Med Date: 2016 Jan-Mar Impact factor: 2.219