Evaluation of the effect of a large volume spacer on the systemic bioactivity of fluticasone propionate metered-dose inhaler.

O J Dempsey1, A M Wilson, W J Coutie, B J Lipworth.   

Abstract

BACKGROUND: Inhaled corticosteroids such as fluticasone propionate (FP) have dose-related systemic effects, including adrenal suppression. We have therefore investigated the effect of adding a large volume spacer on the systemic bioactivity of FP given via a pressurized metered-dose inhaler (pMDI).
METHODS: Fourteen healthy volunteers (mean age, 29.9 years old) were studied using an open, randomized, placebo-controlled, three-way crossover design. Single doses of the following were given at 5:00 PM in a randomized sequence: (1) eight puffs of FP by pMDI, 1.76 mg (250 microg ex-valve, 220 microg ex-actuator); (2) eight puffs of FP by pMDI, 250 microg, with 750-mL spacer (Volumatic; Allen & Hanburys; Uxbridge, UK); and (3) eight puffs of placebo by pMDI. Measurements were made after each dose, including overnight and early morning urinary cortisol/creatinine ratios and 8:00 AM serum cortisol.
RESULTS: Significant (p < 0.05) suppression of all three end points occurred with each active treatment compared to treatment with placebo. Furthermore, significant (p < 0.05) additional suppression occurred when comparing FP by pMDI alone to FP by pMDI with spacer. Geometric mean fold differences (95% confidence interval for fold difference) between FP by pMDI alone and FP by pMDI with spacer were 1.94-fold (1.00-3.78) for overnight urinary cortisol/creatinine ratio and 1.98-fold (1.26-3.10) for 8:00 AM serum cortisol. This was mirrored by a twofold rise in the number of values for uncorrected overnight urinary cortisol < 10 nmol/10 h: placebo treatment (none of 14 subjects); FP by pMDI (6 of 14 subjects; 43%); and FP by pMDI with spacer (12 of 14 subjects; 86%).
CONCLUSIONS: The use of a large volume spacer with FP by pMDI results in a twofold increase in the systemic bioavailability as assessed by sensitive measures of adrenal suppression. This, in turn, reflects a twofold improvement in respirable dose delivery with the spacer device.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10531156     DOI: 10.1378/chest.116.4.935

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  11 in total

1.  Comparative lung bioavailability of fluticasone/salmeterol via a breath-actuated spacer and conventional plastic spacers.

Authors:  Arun Nair; Lorna McKinlay; Peter Williamson; Philip Short; Patricia Burns; Brian J Lipworth
Journal:  Eur J Clin Pharmacol       Date:  2011-01-15       Impact factor: 2.953

Review 2.  Antiasthmatic drug delivery in children.

Authors:  Elizabeth Biggart; Andrew Bush
Journal:  Paediatr Drugs       Date:  2002       Impact factor: 3.022

3.  Effect of AeroChamber Plus™ on the lung and systemic bioavailability of beclometasone dipropionate/formoterol pMDI.

Authors:  Dave Singh; Sara Collarini; Gianluigi Poli; Daniela Acerbi; Alessio Amadasi; Antonio Rusca
Journal:  Br J Clin Pharmacol       Date:  2011-12       Impact factor: 4.335

4.  Systemic bioavailability of hydrofluoroalkane (HFA) formulations of fluticasone/salmeterol in healthy volunteers via pMDI alone and spacer.

Authors:  Karine L Clearie; Peter A Williamson; Sriram Vaidyanathan; Jeannine Du Bois; Haylene Nell; Brian J Lipworth
Journal:  Br J Clin Pharmacol       Date:  2010-06       Impact factor: 4.335

Review 5.  Safety of inhaled and intranasal corticosteroids: lessons for the new millennium.

Authors:  B J Lipworth; C M Jackson
Journal:  Drug Saf       Date:  2000-07       Impact factor: 5.606

6.  Systemic exposure to fluticasone MDI delivered through antistatic chambers.

Authors:  Mai K Elmallah; Yasmeen Khan; Guenther Hochhaus; Jonathan J Shuster; Leslie Hendeles
Journal:  J Allergy Clin Immunol       Date:  2011-07-23       Impact factor: 10.793

7.  Respirable dose delivery of fluticasone propionate from a small valved holding chamber, a compact breath actuated integrated vortex device and a metered dose inhaler.

Authors:  Arun Nair; Daniel Menzies; Martyn Barnes; Patricia Burns; Lesley McFarlane; Brian J Lipworth
Journal:  Br J Clin Pharmacol       Date:  2008-03-13       Impact factor: 4.335

8.  In vivo comparison of the relative systemic bioavailability of fluticasone propionate from three anti-static spacers and a metered dose inhaler.

Authors:  Arun Nair; Daniel Menzies; Pippa Hopkinson; Lesley McFarlane; Brian J Lipworth
Journal:  Br J Clin Pharmacol       Date:  2009-02-09       Impact factor: 4.335

9.  The presence of emphysema does not affect the systemic bioactivity of inhaled fluticasone in severe chronic obstructive pulmonary disease.

Authors:  Daniel K C Lee; Brian J Lipworth
Journal:  Br J Clin Pharmacol       Date:  2004-04       Impact factor: 4.335

10.  A Pilot Study of the Normative Range of Overnight Urinary Free Cortisol Corrected for Creatinine in Children.

Authors:  Ole D Wolthers; Sabine Mersmann; Sanjeeva Dissanayake
Journal:  Clin Drug Investig       Date:  2018-04       Impact factor: 2.859