A detector for a chronic implantable atrial tachyarrhythmia monitor.

Shantanu Sarkar1, David Ritscher, Rahul Mehra.   

Abstract

Continuous long-term monitoring of atrial fibrillation (AF) and tachycardia (AT) is an unmet clinical need, which could be met with a chronically-implanted monitor. Improved therapeutic decisions based on accurate monitoring of parameters, such as daily AF/AT burden (hours/ day) may lead to improvements in clinical outcomes such as reduction in hospitalizations, symptoms, and strokes. This paper describes an AF/AT detector that detects AF as well as AT with an irregular ventricular response, and a supplementary AT detector for AT with more regular ventricular response. Seven databases with significant durations of AF, AT, and sinus rhythm were used to evaluate the performance of the detectors. All patient records with AF (N = 124) were detected by the AF/AT detector to have AF/AT burden with a mean, median, and 75 percentile of absolute error in burden detection of 8.8, 0, and 4 min, respectively. In patients having AF burden (= or > 10 min), the AF/AT detector was found to have burden accuracy within 20% of true burden in 96% of patients. The specificity was 94%, defined as follows: in patient records without AF/AT (N = 174), the percentage with AF/AT burden = or < 10 min in the 24-h recordings. The AF/AT detector underestimatesAT burden, thus degrading performance, in patients with significant amounts of AT with more regular ventricular response. The supplementary AT detector reduces the underestimation of AT while overestimating burden in patients without a significant amount of AT. The detectors described here could be implemented in an implantable monitor for accurate long-term AF/AT monitoring.

Entities:  

Mesh:

Year:  2008        PMID: 18334416     DOI: 10.1109/TBME.2007.903707

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  26 in total

1.  Phased multipolar radiofrequency pulmonary vein isolation is as effective and safe as conventional irrigated point-to-point ablation. A prospective randomised 1-year implantable cardiac monitoring device follow-up trial.

Authors:  S J Podd; A N Sulke; C Sugihara; S S Furniss
Journal:  J Interv Card Electrophysiol       Date:  2015-08-27       Impact factor: 1.900

2.  Surveillance of AF recurrence post-surgical AF ablation using implantable cardiac monitor.

Authors:  John H Ip; Maria Viqar-Syed; Denise Grimes; Yan Xie; Kevin Jager; Jennifer Boak; Divyakant Gandhi
Journal:  J Interv Card Electrophysiol       Date:  2011-08-04       Impact factor: 1.900

3.  AF Detected on Implanted Cardiac Implantable Electronic Devices: Is There a Threshold for Thromboembolic Risk?

Authors:  Motaz Baibars; Khalil Kanjwal; Joseph E Marine
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-03

Review 4.  Rate Control in Atrial Fibrillation: Methods for Assessment, Targets for Ventricular Rate during AF, and Clinical Relevance for Device Therapy.

Authors:  Shantanu Sarkar; Paul D Ziegler
Journal:  J Atr Fibrillation       Date:  2013-06-30

Review 5.  The Temporal Relationship Between Atrial Fibrillation and Ischemic Stroke.

Authors:  Paul D Ziegler
Journal:  J Atr Fibrillation       Date:  2013-02-12

6.  An Interpretable Hand-Crafted Feature-Based Model for Atrial Fibrillation Detection.

Authors:  Rahimeh Rouhi; Marianne Clausel; Julien Oster; Fabien Lauer
Journal:  Front Physiol       Date:  2021-05-13       Impact factor: 4.566

7.  Detection of occult paroxysmal atrial fibrillation.

Authors:  Andrius Petrėnas; Leif Sörnmo; Arūnas Lukoševičius; Vaidotas Marozas
Journal:  Med Biol Eng Comput       Date:  2014-12-14       Impact factor: 2.602

8.  A novel application for the detection of an irregular pulse using an iPhone 4S in patients with atrial fibrillation.

Authors:  David D McManus; Jinseok Lee; Oscar Maitas; Nada Esa; Rahul Pidikiti; Alex Carlucci; Josephine Harrington; Eric Mick; Ki H Chon
Journal:  Heart Rhythm       Date:  2012-12-06       Impact factor: 6.343

9.  [Atrial fibrillation. New aspects for diagnosis and follow-up].

Authors:  C Eitel; G Hindricks; C Piorkowski
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-12

10.  Performance of an external transtelephonic loop recorder for automated detection of paroxysmal atrial fibrillation.

Authors:  Bob Oude Velthuis; Jorieke Bos; Karin Kraaier; Jeroen Stevenhagen; Jurren M van Opstal; Job van der Palen; Marcoen F Scholten
Journal:  Ann Noninvasive Electrocardiol       Date:  2013-09-09       Impact factor: 1.468

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.