Literature DB >> 24303971

Performance of an external transtelephonic loop recorder for automated detection of paroxysmal atrial fibrillation.

Bob Oude Velthuis1, Jorieke Bos, Karin Kraaier, Jeroen Stevenhagen, Jurren M van Opstal, Job van der Palen, Marcoen F Scholten.   

Abstract

BACKGROUND: Although atrial fibrillation (AF) is the most commonly encountered arrhythmia, some of the properties make its detection challenging. In daily practice, underdiagnosis can lead to less effective treatment in prevention of stroke. Based on data from studies on treatment of AF, more intensive follow-up strategies, including 7-day Holter recording, 30-day event recording, and even implantable cardiac monitoring devices, are suggested. The study purpose is to evaluate the performance of a continuous single-channel loop recorder with automatic AF detection and transtelephonic electrocardiogram (ECG) transmission capabilities. METHODS AND
RESULTS: A consecutive cohort of 153 patients admitted to the stroke unit with a presumptive diagnosis of ischemic cerebrovascular accident was screened for AF. Twenty-four-hour rhythm observation was performed using a single-channel external loop recorder (ELR) configured for automated AF detection. A total of 45 patients with a known history of AF, AF on the admission ECG, or incomplete registrations were excluded. Extensive additional frequency-based settings were used to establish a reference registration. In total, 2923 recordings were transmitted. We evaluated all events, of which 1190 were designated by the device as AF. The sensitivity, specificity, PPV, and NPV for identifying AF using the ELR were, respectively, 93%, 51%, 5%, and 99%.
CONCLUSIONS: In this ELR validation study, the dedicated AF detection algorithm showed to be highly sensitive but not specific for AF. Applicability of an ELR might be limited for efficacious detection of AF, as manual verification is mandatory for a vast amount of recordings. ©2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  atrial fibrillation; monitoring; stroke; validation

Mesh:

Year:  2013        PMID: 24303971      PMCID: PMC6932654          DOI: 10.1111/anec.12075

Source DB:  PubMed          Journal:  Ann Noninvasive Electrocardiol        ISSN: 1082-720X            Impact factor:   1.468


  18 in total

Review 1.  Pathophysiology and prevention of atrial fibrillation.

Authors:  M A Allessie; P A Boyden; A J Camm; A G Kléber; M J Lab; M J Legato; M R Rosen; P J Schwartz; P M Spooner; D R Van Wagoner ; A L Waldo
Journal:  Circulation       Date:  2001-02-06       Impact factor: 29.690

2.  A structured reading algorithm improves telemetric detection of atrial fibrillation after acute ischemic stroke.

Authors:  Bernd Kallmünzer; Lorenz Breuer; Christiane Hering; Dorette Raaz-Schrauder; Rainer Kollmar; Hagen B Huttner; Stefan Schwab; Martin Köhrmann
Journal:  Stroke       Date:  2012-02-02       Impact factor: 7.914

3.  Positive predictive value of device-detected atrial high-rate episodes at different rates and durations: an analysis from ASSERT.

Authors:  Elizabeth S Kaufman; Carsten W Israel; Girish M Nair; Luciana Armaganijan; Syamkumar Divakaramenon; Georges H Mairesse; Axel Brandes; Eugene Crystal; Otto Costantini; Roopinder K Sandhu; Ratika Parkash; Stuart J Connolly; Stefan H Hohnloser; Jeff S Healey
Journal:  Heart Rhythm       Date:  2012-03-20       Impact factor: 6.343

4.  2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; José Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  Heart Rhythm       Date:  2012-03-01       Impact factor: 6.343

5.  Is 7-day event triggered ECG recording equivalent to 7-day Holter ECG recording for atrial fibrillation screening?

Authors:  Laurent Roten; Manuel Schilling; Andreas Häberlin; Jens Seiler; Nicola G Schwick; Jürg Fuhrer; Etienne Delacrétaz; Hildegard Tanner
Journal:  Heart       Date:  2012-03-07       Impact factor: 5.994

6.  Impact of atrial fibrillation on the risk of death: the Framingham Heart Study.

Authors:  E J Benjamin; P A Wolf; R B D'Agostino; H Silbershatz; W B Kannel; D Levy
Journal:  Circulation       Date:  1998-09-08       Impact factor: 29.690

7.  Symptomatic and asymptomatic atrial fibrillation in patients undergoing radiofrequency catheter ablation.

Authors:  Chandrasekhar R Vasamreddy; Darshan Dalal; Jun Dong; Alan Cheng; David Spragg; Sameh Z Lamiy; Glenn Meininger; Charles A Henrikson; Joseph E Marine; Ronald Berger; Hugh Calkins
Journal:  J Cardiovasc Electrophysiol       Date:  2006-02

8.  Stroke severity in atrial fibrillation. The Framingham Study.

Authors:  H J Lin; P A Wolf; M Kelly-Hayes; A S Beiser; C S Kase; E J Benjamin; R B D'Agostino
Journal:  Stroke       Date:  1996-10       Impact factor: 7.914

9.  A detector for a chronic implantable atrial tachyarrhythmia monitor.

Authors:  Shantanu Sarkar; David Ritscher; Rahul Mehra
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

10.  Performance of an implantable automatic atrial fibrillation detection device: impact of software adjustments and relevance of manual episode analysis.

Authors:  Charlotte Eitel; Daniela Husser; Gerhard Hindricks; Manuela Frühauf; Sebastian Hilbert; Arash Arya; Thomas Gaspar; Ulrike Wetzel; Andreas Bollmann; Christopher Piorkowski
Journal:  Europace       Date:  2011-02-16       Impact factor: 5.214

View more
  2 in total

Review 1.  Cryptogenic Stroke And Role Of Loop Recorder.

Authors:  Jordi PérezRodon; Jaume FranciscoPascual; Nuria RivasGándara; Ivo RocaLuque; Neus Bellera; Àngel MoyaMitjans
Journal:  J Atr Fibrillation       Date:  2014-12-31

2.  Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye.

Authors:  B Oude Velthuis; M Molenaar; H G Reinhart Dorman; J Y Stevenhagen; M F Scholten; J van der Palen; J M van Opstal
Journal:  Neth Heart J       Date:  2017-06       Impact factor: 2.380

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.