Literature DB >> 18329478

Beating-heart patch closure of muscular ventricular septal defects under real-time three-dimensional echocardiographic guidance: a preclinical study.

Nikolay V Vasilyev1, Ivan Melnychenko, Kazuo Kitahori, Franz P Freudenthal, Alistair Phillips, Rainer Kozlik-Feldmann, Ivan S Salgo, Pedro J del Nido, Emile A Bacha.   

Abstract

OBJECTIVES: Safe and effective device closure of ventricular septal defects remains a challenge. We have developed a transcardiac approach to close ventricular septal defects using a patch delivery and fixation system that can be secured under real-time three-dimensional echocardiographic guidance.
METHODS: In Yorkshire pigs (n = 8) a coring device was introduced into the left ventricle through a purse-string suture placed on the left ventricular apex, and a muscular ventricular septal defect was created. The patch deployment device containing a 20-mm polyester patch was advanced toward the ventricular septal defect through another purse-string suture on the left ventricular apex, and the patch was deployed under real-time three-dimensional echocardiographic guidance. The anchor delivery device was then introduced into the left ventricle through the first purse-string suture. Nitinol anchors to attach the patch around the ventricular septal defect were deployed under real-time three-dimensional echocardiographic guidance. After patch attachment, residual shunts were sought by means of two-dimensional and three-dimensional color Doppler echocardiography. The heart was then excised, and the septum with the patch was inspected.
RESULTS: A ventricular septal defect was created in the midventricular (n = 4), anterior (n = 2), and apical (n = 2) septum. The mean size was 9.8 mm (8.2-12.0 mm), as determined by means of two-dimensional color Doppler scanning. The ventricular septal defects were completely closed in 7 animals. In one a 2.4-mm residual shunt was identified. No anatomic structures were compromised.
CONCLUSIONS: Beating-heart perventricular muscular ventricular septal defect closure without cardiopulmonary bypass can be successfully achieved by using a catheter-based patch delivery and fixation system under real-time three-dimensional echocardiographic guidance. This approach might be a better alternative to cardiac surgery or transcatheter device closure.

Entities:  

Mesh:

Year:  2008        PMID: 18329478      PMCID: PMC2350207          DOI: 10.1016/j.jtcvs.2007.09.045

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  18 in total

1.  The results of direct vision closure of ventricular septal defects in eight patients by means of controlled cross circulation.

Authors:  C W LILLEHEI; M COHEN; H E WARDEN; N R ZIEGLER; R L VARCO
Journal:  Surg Gynecol Obstet       Date:  1955-10

2.  Imaging artifacts of medical instruments in ultrasound-guided interventions.

Authors:  Jinlan Huang; John K Triedman; Nikolay V Vasilyev; Yoshihiro Suematsu; Robin O Cleveland; Pierre E Dupont
Journal:  J Ultrasound Med       Date:  2007-10       Impact factor: 2.153

3.  Repair of aortic-left atrial fistula following the transcatheter closure of an atrial septal defect.

Authors:  Dennis M Mello; John Fahey; Gary S Kopf
Journal:  Ann Thorac Surg       Date:  2005-10       Impact factor: 4.330

4.  Three-dimensional echo-guided beating heart surgery without cardiopulmonary bypass: atrial septal defect closure in a swine model.

Authors:  Yoshihiro Suematsu; Joseph F Martinez; Benjamin K Wolf; Gerald R Marx; Jeffrey A Stoll; Pierre E DuPont; Robert D Howe; John K Triedman; Pedro J del Nido
Journal:  J Thorac Cardiovasc Surg       Date:  2005-10-13       Impact factor: 5.209

5.  Transapical transcatheter aortic valve implantation in humans: initial clinical experience.

Authors:  Samuel V Lichtenstein; Anson Cheung; Jian Ye; Christopher R Thompson; Ronald G Carere; Sanjeevan Pasupati; John G Webb
Journal:  Circulation       Date:  2006-07-31       Impact factor: 29.690

6.  Perventricular device closure of muscular ventricular septal defects on the beating heart: technique and results.

Authors:  Emile A Bacha; Qi-Ling Cao; Joanne P Starr; David Waight; Makram R Ebeid; Ziyad M Hijazi
Journal:  J Thorac Cardiovasc Surg       Date:  2003-12       Impact factor: 5.209

7.  Endocarditis after closure of ventricular septal defect by transcatheter device.

Authors:  Oded Scheuerman; Elchanan Bruckheimer; Nufar Marcus; Vered Hoffer; Ben-Zion Garty
Journal:  Pediatrics       Date:  2006-05-01       Impact factor: 7.124

8.  Current incidence of acute neurologic complications after open-heart operations in children.

Authors:  Caroline C Menache; Adré J du Plessis; David L Wessel; Richard A Jonas; Jane W Newburger
Journal:  Ann Thorac Surg       Date:  2002-06       Impact factor: 4.330

9.  Intraoperative device closure of perimembranous ventricular septal defects without cardiopulmonary bypass: preliminary results with the perventricular technique.

Authors:  Zahid Amin; David A Danford; John Lof; Kim F Duncan; Stacey Froemming
Journal:  J Thorac Cardiovasc Surg       Date:  2004-01       Impact factor: 5.209

10.  Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal defect occluder: immediate and mid-term results of a U.S. registry.

Authors:  Ralf Holzer; David Balzer; Qi-Ling Cao; Ken Lock; Ziyad M Hijazi
Journal:  J Am Coll Cardiol       Date:  2004-04-07       Impact factor: 24.094

View more
  6 in total

1.  A novel cardioport for beating-heart, image-guided intracardiac surgery.

Authors:  Nikolay V Vasilyev; Mitsuhiro Kawata; Christopher M DiBiasio; Keith V Durand; Jonathan Hopkins; Zachary J Traina; Alexander H Slocum; Pedro J del Nido
Journal:  J Thorac Cardiovasc Surg       Date:  2011-09-08       Impact factor: 5.209

Review 2.  Robotics and imaging in congenital heart surgery.

Authors:  Nikolay V Vasilyev; Pierre E Dupont; Pedro J del Nido
Journal:  Future Cardiol       Date:  2012-03

3.  Beating-heart mitral valve chordal replacement.

Authors:  Genevieve Laing; Pierre E Dupont
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

4.  Cardioscopic Tool-delivery Instrument for Beating-heart Surgery.

Authors:  Asghar Ataollahi; Ignacio Berra; Nikolay V Vasilyev; Zurab Machaidze; Pierre E Dupont
Journal:  IEEE ASME Trans Mechatron       Date:  2015-10-26       Impact factor: 5.303

5.  Robotic tissue tracking for beating heart mitral valve surgery.

Authors:  Shelten G Yuen; Nikolay V Vasilyev; Pedro J del Nido; Robert D Howe
Journal:  Med Image Anal       Date:  2010-07-06       Impact factor: 8.545

6.  New technologies for surgery of the congenital cardiac defect.

Authors:  David Kalfa; Emile Bacha
Journal:  Rambam Maimonides Med J       Date:  2013-07-25
  6 in total