Literature DB >> 15063439

Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal defect occluder: immediate and mid-term results of a U.S. registry.

Ralf Holzer1, David Balzer, Qi-Ling Cao, Ken Lock, Ziyad M Hijazi.   

Abstract

OBJECTIVES: We sought to report the results of a U.S. registry of device closure of congenital muscular ventricular septal defects (VSDs) using the new Amplatzer mVSD occluder (AGA Medical Corp., Golden Valley, Minnesota).
BACKGROUND: Muscular VSDs pose a significant surgical challenge with increased morbidity and mortality.
METHODS: Data were prospectively collected from 83 procedures involving 75 patients who underwent an attempt of percutaneous (70 [93.3%] of 75) and/or perventricular (surgical) (6 [8.0%] of 75) device closure of hemodynamically significant muscular VSDs. The patients' median age was 1.4 years (range 0.1 to 54.1 years). Outcome parameters were procedural success, evidence of residual shunts on echocardiography, and occurrence of procedure-related complications. The median follow-up was 211 days (range 1 to 859 days).
RESULTS: The median size of the primary VSD was 7 mm (range 3 to 16 mm) and in 34 of 78 (43.6%) procedures, patients had multiple VSDs (range 2 to 7). The device was implanted successfully in 72 of 83 (86.7%) procedures. In 17 of 83 (20.5%) procedures, multiple devices were implanted (range 2 to 3). Procedure-related major complications occurred in 8 of 75 (10.7%) patients. Device embolization occurred in two patients and cardiac perforation in one patient. There were two (2.7%) procedure-related deaths. The 24-h postprocedural complete closure rate was 47.2% (34 of 72 patients), increasing to 69.6% (32 of 46 patients) at 6 months and 92.3% (24 of 26 patients) at 12 months. Six patients underwent successful closure using the perventricular surgical (beating heart) approach, with complete closure at day 1 in three patients and trivial/small residual shunts in the remainder of the patients.
CONCLUSIONS: The Amplatzer mVSD device (AGA Medical Corp.) offers excellent closure rates and low mortality when used to close congenital muscular VSDs. The device appears to be safe and effective.

Entities:  

Mesh:

Year:  2004        PMID: 15063439     DOI: 10.1016/j.jacc.2003.10.047

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  43 in total

Review 1.  Embolization and transcatheter retrieval of coils and devices.

Authors:  C A Tan; D S Levi; J W Moore
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

Review 2.  Catheter closure of congenital muscular ventricular septal defects.

Authors:  B D Thanopoulos
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

3.  Retrograde percutaneous closure of a ventricular septal defect after myectomy for hypertrophic obstructive cardiomyopathy.

Authors:  Vikas Singh; Apurva O Badheka; Syed S Bokhari; Eduard Ghersin; Pedro Martinez Clark; William W O'Neill
Journal:  Tex Heart Inst J       Date:  2013

Review 4.  Current topics in surgery for multiple ventricular septal defects.

Authors:  Naoki Yoshimura; Kazuaki Fukahara; Akio Yamashita; Yoshinori Doki; Katsunori Takeuchi; Tomonori Higuma; Kazutaka Senda; Masayoshi Toge; Tatsuro Matsuo; Saori Nagura; Masaya Aoki; Kimimasa Sakata; Mari Sakai
Journal:  Surg Today       Date:  2015-05-03       Impact factor: 2.549

5.  Canadian Cardiovascular Society 2009 Consensus Conference on the management of adults with congenital heart disease: shunt lesions.

Authors:  Candice K Silversides; Annie Dore; Nancy Poirier; Dylan Taylor; Louise Harris; Matthias Greutmann; Lee Benson; Helmut Baumgartner; David Celermajer; Judith Therrien
Journal:  Can J Cardiol       Date:  2010-03       Impact factor: 5.223

6.  Transcatheter closure of perimembranous ventricular septal defects (VSD) with VSD occluder: early and mid-term results.

Authors:  Yidong Wei; Xian Wang; Shouyan Zhang; Lei Hou; Yong Wang; Yawei Xu; Qi Sun; Huaibing Zhao
Journal:  Heart Vessels       Date:  2011-05-27       Impact factor: 2.037

7.  Hybrid muscular ventricular septal defect closure: surgeon or physician!!

Authors:  Nageswara Rao Koneti
Journal:  Indian Heart J       Date:  2012-10-29

8.  Perventricular device closure of isolated muscular ventricular septal defect in infants: a single centre experience.

Authors:  Bhavesh Thakkar; Nehal Patel; Shaunak Shah; Vishal Poptani; Tarun Madan; Chirag Shah; Anand Shukla; Vaishali Prajapati
Journal:  Indian Heart J       Date:  2012-09-12

9.  Percutaneous closure of ventricular septal defect associated with tunnel-shaped aneurysm using the Amplatzer duct occluder.

Authors:  Muhammad Dilawar; Mohammed Numan; Amal El-Sisi; Salwa Morcos Gendi; Zaheer Ahmad
Journal:  Pediatr Cardiol       Date:  2007-10-20       Impact factor: 1.655

10.  Perventricular closure of muscular ventricular septal defects: How do I do it?

Authors:  Karim A Diab; Qi-Ling Cao; Ziyad M Hijazi
Journal:  Ann Pediatr Cardiol       Date:  2008-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.