Literature DB >> 18325178

Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference.

Heinz Jürgen Roth1, Heinrich Schmidt-Gayk, Holger Weber, Christoph Niederau.   

Abstract

BACKGROUND: The most reliable assessment of vitamin D status is measurement of plasma 25-hydroxyvitamin D (25[OH]D) concentration. High variability in 25(OH)D measurements due to utilized test and assay technologies and the lack of standardization against reference materials and reference method often confounds proper assessment of vitamin D status.
METHODS: We evaluated the accuracy of six routinely available methodologies: high-performance liquid chromatography (HPLC), the IDS-radioimmunoassay (IDS-RIA) and enzyme immunoassay (IDS-EIA), the Nichols Advantage automated protein-binding assay (Advantage), two versions of the DiaSorin automated immunoassay (Liaison 1 and Liaison 2)--and one prototype automated immunoassay (Elecsys) for assessment of the 25(OH)D(3) status in a cohort of 300 randomly selected patients' samples compared with the reference method liquid chromatography-tandem mass spectrometry (LC-MS/MS).
RESULTS: Passing-Bablok regression analysis demonstrated a slope for each method compared with LC-MS/MS that varied from 0.62 (IDS-EIA) to 1.0 (HPLC). The Advantage and the Liaison 1 showed significant deviation from linearity with highly variable individual results vs. the LC-MS/MS. Difference plots revealed a considerable persistent proportional bias for the IDS-RIA and IDS-EIA. All evaluated methods except HPLC demonstrated a more or less considerable deviation of individual 25(OH)D(3) values compared with LC-MS/MS defined target concentrations.
CONCLUSIONS: Standardization of methods for the quantification of 25(OH)D on a human-based sample panel by means of LCMS/MS would help to reduce the inter-method variability with respect to accuracy existing in 25(OH)D measurement considerably. However, there will still remain differences in the accuracy of methods utilizing sample purification before final quantification or immunological reaction when compared with those methods without separate sample purification.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18325178     DOI: 10.1258/acb.2007.007091

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  92 in total

1.  Development and certification of a standard reference material for vitamin D metabolites in human serum.

Authors:  Karen W Phinney; Mary Bedner; Susan S-C Tai; Veronica V Vamathevan; Lane C Sander; Katherine E Sharpless; Stephen A Wise; James H Yen; Rosemary L Schleicher; Madhulika Chaudhary-Webb; Christine M Pfeiffer; Joseph M Betz; Paul M Coates; Mary Frances Picciano
Journal:  Anal Chem       Date:  2011-12-28       Impact factor: 6.986

2.  Weight loss is associated with increased serum 25-hydroxyvitamin D in overweight or obese women.

Authors:  Cheryl L Rock; Jennifer A Emond; Shirley W Flatt; Dennis D Heath; Njeri Karanja; Bilge Pakiz; Nancy E Sherwood; Cynthia A Thomson
Journal:  Obesity (Silver Spring)       Date:  2012-03-08       Impact factor: 5.002

3.  25- hydroxyvitamin d: explosion in clinical interest and laboratory requests.

Authors:  Waad-Allah Mula-Abed
Journal:  Oman Med J       Date:  2009-10

4.  Determinants of vitamin D status among overweight and obese Puerto Rican adults.

Authors:  Cristina Palacios; Karen Gil; Cynthia M Pérez; Kaumudi Joshipura
Journal:  Ann Nutr Metab       Date:  2012-01-04       Impact factor: 3.374

Review 5.  Vitamin D in pregnancy: current concepts.

Authors:  Rachel P Urrutia; John M Thorp
Journal:  Curr Opin Obstet Gynecol       Date:  2012-03       Impact factor: 1.927

6.  NHANES monitoring of serum 25-hydroxyvitamin D: a roundtable summary.

Authors:  Elizabeth A Yetley; Christine M Pfeiffer; Rosemary L Schleicher; Karen W Phinney; David A Lacher; Sylvia Christakos; John H Eckfeldt; James C Fleet; George Howard; Andrew N Hoofnagle; Siu L Hui; Gary L Lensmeyer; Joseph Massaro; Munro Peacock; Bernard Rosner; Donald Wiebe; Regan L Bailey; Paul M Coates; Anne C Looker; Christopher Sempos; Clifford L Johnson; Mary Frances Picciano
Journal:  J Nutr       Date:  2010-09-29       Impact factor: 4.798

7.  Short-term Variability of Vitamin D-Related Biomarkers.

Authors:  Pamela L Lutsey; Christina M Parrinello; Jeffrey R Misialek; Andy N Hoofnagle; Clark M Henderson; Thomas J Laha; Erin D Michos; John H Eckfeldt; Elizabeth Selvin
Journal:  Clin Chem       Date:  2016-09-30       Impact factor: 8.327

8.  Surge in US outpatient vitamin D deficiency diagnoses: National Ambulatory Medical Care Survey analysis.

Authors:  Karen E Huang; Brandy-Joe Milliron; Scott A Davis; Steven R Feldman
Journal:  South Med J       Date:  2014-04       Impact factor: 0.954

Review 9.  Vitamin D and metabolites measurement by tandem mass spectrometry.

Authors:  Johannes M W van den Ouweland; Michael Vogeser; Silvia Bächer
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

10.  Serum vitamin D₃ does not correlate with liver fibrosis in chronic hepatitis C.

Authors:  Yan Ren; Mei Liu; Jing Zhao; Feng Ren; Yu Chen; Jun-Feng Li; Jing-Yun Zhang; Feng Qu; Jin-Lan Zhang; Zhong-Ping Duan; Su-Jun Zheng
Journal:  World J Gastroenterol       Date:  2015-10-21       Impact factor: 5.742