| Literature DB >> 18323701 |
Kyung Hoon Kim1, Jaewan Choi, Chang Hwan Lee, Beom Jin Cho, Michael S Kook.
Abstract
PURPOSE: To evaluate the structure-function relationships between retinal sensitivity measured by Humphrey visual field analyzer (HVFA) and the retinal nerve fiber layer (RNFL) thickness measured by scanning laser polarimetry (SLP) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) in glaucomatous and healthy eyes.Entities:
Mesh:
Year: 2008 PMID: 18323701 PMCID: PMC2629948 DOI: 10.3341/kjo.2008.22.1.18
Source DB: PubMed Journal: Korean J Ophthalmol ISSN: 1011-8942
Fig. 1Correspondence map of the GDx-VCC regional parameters (A) and the HVFA 24-2 paradigm (B) for a right eye. In the present study, peripapillary GDx-VCC measurements and visual field test points were grouped into two regional corresponding sectors of superior and inferior average on the GDx-VCC printouts, based on the article by Garway-Heath et al.21 Corresponding sectors were grayscaled and named after the parameters on the GDx-VCC printouts (Superior and inferior average) in relation to the optic disc.
Descriptive statistics for demographics and clinical characteristics of the study patients
Data are mean±SD values, except for TSS (median value). *P<0.05, independent samples t-test between glaucomatous and normal eyes; †P<0.05, paired t-test between VCC and ECC; ‡P<0.05, Wilcoxon signed ranks test between VCC and ECC. Abbreviations: ABP=atypical birefringence pattern; SE=spherical equivalent; IOP=intraocular pressure; CCT=central corneal thickness; dB=decibel; MD=mean deviation; PSD=pattern standard deviation; MS=mean sensitivity; SLP=scanning laser polarimetry; VCC=variable corneal compensation; ECC=enhanced corneal compensation; TSNIT=temporal, superior, nasal, inferior and temporal; TSS=typical scan score.
Linear regression analyses between SLP parameters and retinal sensitivity expressed in the dB and 1/L scales
*P<0.05, linear regression; †P<0.05, Wilcoxon signed ranks test of absolute prediction errors between VCC and ECC.
Abbreviations: SLP=scanning laser polarimetry; dB=decibel; L=Lambert; ABP=atypical birefringence pattern; MS=mean sensitivity.
Fig. 2Scatterplots showing the associations between VCC and ECC parameters and corresponding retinal sensitivities expressed in dB by linear regression in eyes with ABP. (A) TSNIT SD with VCC and ECC versus global mean sensitivity (MS) expressed in dB. (B) Superior average with VCC and ECC versus inferior MS expressed in dB. (C) Inferior average with VCC and ECC versus superior MS expressed in dB. R2 values were significantly higher for linear associations of these SLP parameters with retinal sensitivity with ECC than with VCC (P-values: A, 0.001; B, 0.002; C, <0.001. Wilcoxon signed ranks test of the absolute prediction errors). Solid lines, linear fits; dashed lines, confidence intervals. R2 values are shown for each fit.