General and self-consistent method for the calibration of polarization modulators, polarimeters, and mueller-matrix ellipsometers.

E Compain1, S Poirier, B Drevillon.   

Abstract

Calibration of polarization-state generators (PSG's), polarimeters, and Mueller-matrix ellipsometers (MME's) is an important factor in the practical use of these instruments. A new general procedure, the eigenvalue calibration method (ECM), is presented. It can calibrate any complete MME consisting of a PSG and a polarimeter that generate and measure, respectively, all the states of polarization of light. In the ECM, the PSG and the polarimeter are described by two 4 x 4 matrices W and A, and their 32 coefficients are determined from three or four measurements performed on reference samples. Those references are smooth isotropic samples and perfect linear polarizers. Their optical characteristics are unambiguously determined during the calibration from the eigenvalues of the measured matrices. The ECM does not require accurate alignment of the various optical elements and does not involve any first-order approximation. The ECM also displays an efficient error control capability that can be used to improve the MME behavior. The ECM is illustrated by an experimental calibration, at two wavelengths (458 and 633 nm), of a MME consisting of a coupled phase modulator associated with a prism division-of-amplitude polarimeter.

Entities:  

Year:  1999        PMID: 18319949     DOI: 10.1364/ao.38.003490

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  21 in total

1.  A multiscale Mueller polarimetry module for a stereo zoom microscope.

Authors:  Adam Gribble; Michael A Pinkert; Jared Westreich; Yuming Liu; Adib Keikhosravi; Mohammadali Khorasani; Sharon Nofech-Mozes; Kevin W Eliceiri; Alex Vitkin
Journal:  Biomed Eng Lett       Date:  2019-06-20

2.  Polarimetric measurement utility for pre-cancer detection from uterine cervix specimens.

Authors:  Meredith Kupinski; Matthieu Boffety; François Goudail; Razvigor Ossikovski; Angelo Pierangelo; Jean Rehbinder; Jérémy Vizet; Tatiana Novikova
Journal:  Biomed Opt Express       Date:  2018-10-25       Impact factor: 3.732

3.  Polarized optical scattering by inhomogeneities and surface roughness in an anisotropic thin film.

Authors:  Thomas A Germer; Katelynn A Sharma; Thomas G Brown; James B Oliver
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2017-11-01       Impact factor: 2.129

4.  Deep learning for denoising in a Mueller matrix microscope.

Authors:  Xiongjie Yang; Qianhao Zhao; Tongyu Huang; Zheng Hu; Tongjun Bu; Honghui He; Anli Hou; Migao Li; Yucheng Xiao; Hui Ma
Journal:  Biomed Opt Express       Date:  2022-05-24       Impact factor: 3.562

5.  Full four-dimensional and reciprocal Mueller matrix bidirectional reflectance distribution function of sintered polytetrafluoroethylene.

Authors:  Thomas A Germer
Journal:  Appl Opt       Date:  2017-11-20       Impact factor: 1.980

6.  Stokes polarimeter optimization in the presence of shot and Gaussian noise.

Authors:  David Lara; Carl Paterson
Journal:  Opt Express       Date:  2009-11-09       Impact factor: 3.894

7.  A high definition Mueller polarimetric endoscope for tissue characterisation.

Authors:  Ji Qi; Daniel S Elson
Journal:  Sci Rep       Date:  2016-05-12       Impact factor: 4.379

8.  Optimized Mass Spectrometry Analysis Workflow with Polarimetric Guidance for ex vivo and in situ Sampling of Biological Tissues.

Authors:  Michael Woolman; Adam Gribble; Emma Bluemke; Jing Zou; Manuela Ventura; Nicholas Bernards; Megan Wu; Howard J Ginsberg; Sunit Das; Alex Vitkin; Arash Zarrine-Afsar
Journal:  Sci Rep       Date:  2017-03-28       Impact factor: 4.379

9.  In vivo imaging of uterine cervix with a Mueller polarimetric colposcope.

Authors:  Jérémy Vizet; Jean Rehbinder; Stanislas Deby; Stéphane Roussel; André Nazac; Ranya Soufan; Catherine Genestie; Christine Haie-Meder; Hervé Fernandez; François Moreau; Angelo Pierangelo
Journal:  Sci Rep       Date:  2017-06-01       Impact factor: 4.379

10.  Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging.

Authors:  Ji Qi; Chao He; Daniel S Elson
Journal:  Biomed Opt Express       Date:  2017-10-10       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.