PURPOSE: To discuss planning target volumes (PTVs) based on internal target volume (PTVITV), exhale-gated radiotherapy (PTVGating), and a new proposed midposition (PTVMidP; time-weighted mean tumor position) and compare them with the conventional free-breathing CT scan PTV (PTVConv). METHODS AND MATERIALS: Respiratory motion induces systematic and random geometric uncertainties. Their contribution to the clinical target volume (CTV)-to-PTV margins differs for each PTV approach. The uncertainty margins were calculated using a dose-probability-based margin recipe (based on patient statistics). Tumor motion in four-dimensional CT scans was determined using a local rigid registration of the tumor. Geometric uncertainties for interfractional setup errors and tumor baseline variation were included. For PTVGating, the residual motion within a 30% gating (time) window was determined. The concepts were evaluated in terms of required CTV-to-PTV margin and PTV volume for 45 patients. RESULTS: Over the patient group, the PTVITV was on average larger (+6%) and the PTVGating and PTVMidP smaller (-10%) than the PTVConv using an off-line (bony anatomy) setup correction protocol. With an on-line (soft tissue) protocol the differences in PTV compared with PTVConv were +33%, -4%, and 0, respectively. CONCLUSIONS: The internal target volume method resulted in a significantly larger PTV than conventional CT scanning. The exhale-gated and mid-position approaches were comparable in terms of PTV. However, mid-position (or mid-ventilation) is easier to use in the clinic because it only affects the planning part of treatment and not the delivery.
PURPOSE: To discuss planning target volumes (PTVs) based on internal target volume (PTVITV), exhale-gated radiotherapy (PTVGating), and a new proposed midposition (PTVMidP; time-weighted mean tumor position) and compare them with the conventional free-breathing CT scan PTV (PTVConv). METHODS AND MATERIALS: Respiratory motion induces systematic and random geometric uncertainties. Their contribution to the clinical target volume (CTV)-to-PTV margins differs for each PTV approach. The uncertainty margins were calculated using a dose-probability-based margin recipe (based on patient statistics). Tumor motion in four-dimensional CT scans was determined using a local rigid registration of the tumor. Geometric uncertainties for interfractional setup errors and tumor baseline variation were included. For PTVGating, the residual motion within a 30% gating (time) window was determined. The concepts were evaluated in terms of required CTV-to-PTV margin and PTV volume for 45 patients. RESULTS: Over the patient group, the PTVITV was on average larger (+6%) and the PTVGating and PTVMidP smaller (-10%) than the PTVConv using an off-line (bony anatomy) setup correction protocol. With an on-line (soft tissue) protocol the differences in PTV compared with PTVConv were +33%, -4%, and 0, respectively. CONCLUSIONS: The internal target volume method resulted in a significantly larger PTV than conventional CT scanning. The exhale-gated and mid-position approaches were comparable in terms of PTV. However, mid-position (or mid-ventilation) is easier to use in the clinic because it only affects the planning part of treatment and not the delivery.
Authors: M Rico; E Martínez; S Pellejero; B Bermejo; P Navarrete; M Barrado; M Campo; F Mañeru; E Villafranca; J Aristu Journal: Clin Transl Oncol Date: 2016-01-12 Impact factor: 3.405
Authors: Hannah Bainbridge; Ahmed Salem; Rob H N Tijssen; Michael Dubec; Andreas Wetscherek; Corinne Van Es; Jose Belderbos; Corinne Faivre-Finn; Fiona McDonald Journal: Transl Lung Cancer Res Date: 2017-12
Authors: Lotte Nygård; Marianne C Aznar; Barbara M Fischer; Gitte F Persson; Charlotte B Christensen; Flemming L Andersen; Mirjana Josipovic; Seppo W Langer; Andreas Kjær; Ivan R Vogelius; Søren M Bentzen Journal: Am J Nucl Med Mol Imaging Date: 2018-04-25