Literature DB >> 18313530

Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients.

Jochem W H Wolthaus1, Jan-Jakob Sonke, Marcel van Herk, José S A Belderbos, Maddalena M G Rossi, Joos V Lebesque, Eugène M F Damen.   

Abstract

PURPOSE: To discuss planning target volumes (PTVs) based on internal target volume (PTVITV), exhale-gated radiotherapy (PTVGating), and a new proposed midposition (PTVMidP; time-weighted mean tumor position) and compare them with the conventional free-breathing CT scan PTV (PTVConv). METHODS AND MATERIALS: Respiratory motion induces systematic and random geometric uncertainties. Their contribution to the clinical target volume (CTV)-to-PTV margins differs for each PTV approach. The uncertainty margins were calculated using a dose-probability-based margin recipe (based on patient statistics). Tumor motion in four-dimensional CT scans was determined using a local rigid registration of the tumor. Geometric uncertainties for interfractional setup errors and tumor baseline variation were included. For PTVGating, the residual motion within a 30% gating (time) window was determined. The concepts were evaluated in terms of required CTV-to-PTV margin and PTV volume for 45 patients.
RESULTS: Over the patient group, the PTVITV was on average larger (+6%) and the PTVGating and PTVMidP smaller (-10%) than the PTVConv using an off-line (bony anatomy) setup correction protocol. With an on-line (soft tissue) protocol the differences in PTV compared with PTVConv were +33%, -4%, and 0, respectively.
CONCLUSIONS: The internal target volume method resulted in a significantly larger PTV than conventional CT scanning. The exhale-gated and mid-position approaches were comparable in terms of PTV. However, mid-position (or mid-ventilation) is easier to use in the clinic because it only affects the planning part of treatment and not the delivery.

Entities:  

Mesh:

Year:  2008        PMID: 18313530     DOI: 10.1016/j.ijrobp.2007.11.042

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  68 in total

1.  The potential for undertaking slow CT using a modern CT scanner.

Authors:  C D Chinneck; M McJury; A R Hounsell
Journal:  Br J Radiol       Date:  2010-06-15       Impact factor: 3.039

2.  Dose-mass inverse optimization for minimally moving thoracic lesions.

Authors:  I B Mihaylov; E G Moros
Journal:  Phys Med Biol       Date:  2015-04-24       Impact factor: 3.609

3.  Comparative evaluation of CT-based and respiratory-gated PET/CT-based planning target volume (PTV) in the definition of radiation treatment planning in lung cancer: preliminary results.

Authors:  Luca Guerra; Sofia Meregalli; Alessandra Zorz; Rita Niespolo; Elena De Ponti; Federica Elisei; Sabrina Morzenti; Sarah Brenna; Andrea Crespi; Gianstefano Gardani; Cristina Messa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-01       Impact factor: 9.236

4.  Simplified strategies to determine the mean respiratory position for liver radiation therapy planning.

Authors:  Michael Velec; Joanne L Moseley; Kristy K Brock
Journal:  Pract Radiat Oncol       Date:  2013-08-08

5.  Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology.

Authors:  Edward D Brandner; Indrin J Chetty; Tawfik G Giaddui; Ying Xiao; M Saiful Huq
Journal:  Med Phys       Date:  2017-04-20       Impact factor: 4.071

Review 6.  Image-guided radiotherapy: from current concept to future perspectives.

Authors:  David A Jaffray
Journal:  Nat Rev Clin Oncol       Date:  2012-11-20       Impact factor: 66.675

7.  Influence of different treatment techniques and clinical factors over the intrafraction variation on lung stereotactic body radiotherapy.

Authors:  M Rico; E Martínez; S Pellejero; B Bermejo; P Navarrete; M Barrado; M Campo; F Mañeru; E Villafranca; J Aristu
Journal:  Clin Transl Oncol       Date:  2016-01-12       Impact factor: 3.405

Review 8.  Magnetic resonance imaging in precision radiation therapy for lung cancer.

Authors:  Hannah Bainbridge; Ahmed Salem; Rob H N Tijssen; Michael Dubec; Andreas Wetscherek; Corinne Van Es; Jose Belderbos; Corinne Faivre-Finn; Fiona McDonald
Journal:  Transl Lung Cancer Res       Date:  2017-12

9.  Repeatability of FDG PET/CT metrics assessed in free breathing and deep inspiration breath hold in lung cancer patients.

Authors:  Lotte Nygård; Marianne C Aznar; Barbara M Fischer; Gitte F Persson; Charlotte B Christensen; Flemming L Andersen; Mirjana Josipovic; Seppo W Langer; Andreas Kjær; Ivan R Vogelius; Søren M Bentzen
Journal:  Am J Nucl Med Mol Imaging       Date:  2018-04-25

10.  New approach in lung cancer radiotherapy offers better normal tissue sparing.

Authors:  Ivaylo B Mihaylov
Journal:  Radiother Oncol       Date:  2016-09-28       Impact factor: 6.280

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.