Literature DB >> 18309609

Marginal fit and microgaps of implant-abutment interface with internal anti-rotation configuration.

Takuma Tsuge1, Yoshiyuki Hagiwara, Hideo Matsumura.   

Abstract

To date, there is no evidence that internal anti-rotation configurations are better than external ones. As part of a study to clarify the features and advantages of internal anti-rotation configurations, the objective of the present investigation was to compare and evaluate the marginal fit and size of microgap at the implant-abutment interface for several external and internal anti-rotation configurations. To this end, three internal connection and two external hex connection implant-abutment assemblies were examined in this study. The implant-abutment interface (I-A interface) was evaluated using three geometrical factors: vertical and horizontal discrepancies and size of microgap. Marginal fit and microgap size were measured by a scanning laser microscope. The I-A interface was also observed using a scanning electron microscope. Mean vertical discrepancy ranged from 22.6 to 62.2 microm, while horizontal discrepancy ranged from -27.1 to 16.0 microm. The microgap values of all I-A interfaces assessed in this study ranged from 2.3 to 5.6 microm. In conclusion, SEM images of I-A interface suggested no relationship between the geometrical factors and the type of anti-rotation configuration.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18309609     DOI: 10.4012/dmj.27.29

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  15 in total

1.  In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

Authors:  A Rack; T Rack; M Stiller; H Riesemeier; S Zabler; K Nelson
Journal:  J Synchrotron Radiat       Date:  2010-02-03       Impact factor: 2.616

Review 2.  Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review.

Authors:  Marcelo Coelho Goiato; Eduardo Piza Pellizzer; Emily Vivianne Freitas da Silva; Liliane da Rocha Bonatto; Daniela Micheline dos Santos
Journal:  Oral Maxillofac Surg       Date:  2015-04-25

3.  Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study.

Authors:  Pedro Molinero-Mourelle; Rocio Cascos-Sanchez; Burak Yilmaz; Walter Yu Hang Lam; Edmond Ho Nang Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

4.  Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant-abutment connection.

Authors:  Wiebke Semper-Hogg; Silvan Kraft; Sebastian Stiller; Juergen Mehrhof; Katja Nelson
Journal:  Clin Oral Investig       Date:  2012-07-22       Impact factor: 3.573

5.  Sealing Capability and SEM Observation of the Implant-Abutment Interface.

Authors:  Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante
Journal:  Int J Dent       Date:  2011-07-02

6.  Marginal bone response of implants with platform switching and non-platform switching abutments in posterior healed sites: a 1-year prospective study.

Authors:  Yun-Chi Wang; Joseph Y K Kan; Kitichai Rungcharassaeng; Phillip Roe; Jaime L Lozada
Journal:  Clin Oral Implants Res       Date:  2014-01-03       Impact factor: 5.977

7.  Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment.

Authors:  Rudys Rodolfo de Jesus Tavarez; Wellington Cardoso Bonachela; Anuar Antônio Xible
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

8.  Physicochemical and microscopic characterization of implant-abutment joints.

Authors:  Patricia A Lopes; Adriana F P Carreiro; Rubens M Nascimento; Brendan R Vahey; Bruno Henriques; Júlio C M Souza
Journal:  Eur J Dent       Date:  2018 Jan-Mar

9.  The influence of implant-abutment connection on the screw loosening and microleakage.

Authors:  Katsuhiro Tsuruta; Yasunori Ayukawa; Tatsuya Matsuzaki; Masafumi Kihara; Kiyoshi Koyano
Journal:  Int J Implant Dent       Date:  2018-04-09

10.  Accuracy combining different brands of implants and abutments.

Authors:  María-Fernanda Solá-Ruíz; Eduardo Selva-Otaolaurruchi; Gisela Senent-Vicente; Inés González-de-Cossio; Vicente Amigó-Borrás
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.