Biocompatibility of an x-shaped zirconium implant in deep sclerectomy in rabbits.

Alessia Basso1, Sylvain Roy, André Mermoud.   

Abstract

BACKGROUND: The aim of this study was to evaluate the mid-term biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery.
METHODS: Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. IOP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed.
RESULTS: For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant.
CONCLUSIONS: The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18305952     DOI: 10.1007/s00417-008-0782-y

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  15 in total

1.  [Non-perforating surgery of the trabeculum with reticulated hyaluronic acid implant: why, how, what results?].

Authors:  P Sourdille; P Y Santiago; Y Ducournau
Journal:  J Fr Ophtalmol       Date:  1999 Aug-Sep       Impact factor: 0.818

2.  Deep sclerectomy with collagen implant: medium term results.

Authors:  M E Karlen; E Sanchez; C C Schnyder; M Sickenberg; A Mermoud
Journal:  Br J Ophthalmol       Date:  1999-01       Impact factor: 4.638

3.  Cationic ferritin changes outflow facility in human eyes whereas anionic ferritin does not.

Authors:  C R Ethier; D W Chan
Journal:  Invest Ophthalmol Vis Sci       Date:  2001-07       Impact factor: 4.799

4.  An ultrasound biomicroscopic study of eyes after deep sclerectomy with collagen implant.

Authors:  A G Chiou; A Mermoud; J P Underdahl; C C Schnyder
Journal:  Ophthalmology       Date:  1998-04       Impact factor: 12.079

5.  Outflow mechanisms after deep sclerectomy with two different designs of collagen implant in an animal model.

Authors:  Christophe Nguyen; Radu Christian Boldea; Sylvain Roy; Tarek Shaarawy; Sylvie Uffer; André Mermoud
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-12       Impact factor: 3.117

6.  Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part I. Pressable and alumina glass-infiltrated ceramics.

Authors:  Massimiliano Guazzato; Mohammad Albakry; Simon P Ringer; Michael V Swain
Journal:  Dent Mater       Date:  2004-06       Impact factor: 5.304

7.  Measurement of rabbit intraocular pressure with the Tono-Pen.

Authors:  A Mermoud; G Baerveldt; D S Minckler; M B Lee; N A Rao
Journal:  Ophthalmologica       Date:  1995       Impact factor: 3.250

8.  Relative fracture toughness and hardness of new dental ceramics.

Authors:  R R Seghi; I L Denry; S F Rosenstiel
Journal:  J Prosthet Dent       Date:  1995-08       Impact factor: 3.426

9.  Comparative study between deep sclerectomy with and without collagen implant: long term follow up.

Authors:  T Shaarawy; C Nguyen; C Schnyder; A Mermoud
Journal:  Br J Ophthalmol       Date:  2004-01       Impact factor: 4.638

Review 10.  Zirconia as a ceramic biomaterial.

Authors:  C Piconi; G Maccauro
Journal:  Biomaterials       Date:  1999-01       Impact factor: 12.479

View more
  3 in total

1.  In vivo biocompatibility assessment of (PTFE-PVDF-PP) terpolymer-based membrane with potential application for glaucoma treatment.

Authors:  Rafał Leszczynski; Ewa Stodolak; Jarosław Wieczorek; Jolanta Orlowska-Heitzman; Teresa Gumula; Stanislaw Blazewicz
Journal:  J Mater Sci Mater Med       Date:  2010-07-23       Impact factor: 3.896

Review 2.  An overview of recent advances in designing orthopedic and craniofacial implants.

Authors:  Venkata P Mantripragada; Beata Lecka-Czernik; Nabil A Ebraheim; Ambalangodage C Jayasuriya
Journal:  J Biomed Mater Res A       Date:  2013-06-14       Impact factor: 4.396

3.  Intrascleral outflow after deep sclerectomy with absorbable and non-absorbable implants in the rabbit eye.

Authors:  Jakub J Kałużny; Dariusz Grzanka; Halina Wiśniewska; Alicja Niewińska; Bartłomiej J Kałużny; Alina Grzanka
Journal:  Med Sci Monit       Date:  2012-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.