Literature DB >> 8570152

Measurement of rabbit intraocular pressure with the Tono-Pen.

A Mermoud1, G Baerveldt, D S Minckler, M B Lee, N A Rao.   

Abstract

A Tono-Pen-1 (TP-1) and a Tono-Pen-2 (TP-2) were calibrated against direct manometry in the eyes of living rabbits to determine the accuracy of the Tono-Pen. Eighteen normal eyes of 10 rabbits were cannulated and connected to a pressure transducer with a chart recorder. Intraocular pressure (IOP) was increased from 5 to 40 mm Hg in 5-mm-Hg increments and from 40 to 80 mm Hg in 10-mm-Hg increments. After each incremental increase, IOP was measured first with a TP-1 and then with a TP-2. Plotting the mean Tono-Pen readings for each eye against the transducer pressure produced the following two regression line formulas: y = -0.613+0.790x (r2 = 0.97) for TP-1, and y = -1.45+0.824x (r2 = 0.97) for TP-2. Neither regression line was statistically different; p = 0.2 for the two slopes, and p = 0.24 for the y-axis intersection. The TP-1 and TP-2 can be used to rapidly and accurately measure the IOP in normal rabbit eyes. Tono-Pen readings do, however, significantly underestimate pressures in the range of 5-80 mm Hg. A table with 95% confidence intervals for corrected IOP readings obtained with the TP-1 or -2 is provided.

Entities:  

Mesh:

Year:  1995        PMID: 8570152     DOI: 10.1159/000310630

Source DB:  PubMed          Journal:  Ophthalmologica        ISSN: 0030-3755            Impact factor:   3.250


  5 in total

1.  Biocompatibility of an x-shaped zirconium implant in deep sclerectomy in rabbits.

Authors:  Alessia Basso; Sylvain Roy; André Mermoud
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-02-28       Impact factor: 3.117

2.  In vivo photoacoustic imaging of chorioretinal oxygen gradients.

Authors:  Ali Hariri; Junxin Wang; Yeji Kim; Anamik Jhunjhunwala; Daniel L Chao; Jesse V Jokerst
Journal:  J Biomed Opt       Date:  2018-03       Impact factor: 3.170

3.  Outflow mechanisms after deep sclerectomy with two different designs of collagen implant in an animal model.

Authors:  Christophe Nguyen; Radu Christian Boldea; Sylvain Roy; Tarek Shaarawy; Sylvie Uffer; André Mermoud
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-12       Impact factor: 3.117

4.  Comparison of Goldmann applanation tonometer, Tono-Pen and noncontact tonometer in children.

Authors:  Usha Kaul Raina; Neha Rathie; Anika Gupta; Shantanu Kumar Gupta; Meenakshi Thakar
Journal:  Oman J Ophthalmol       Date:  2016 Jan-Apr

5.  Tono-Pen XL tonometry during application of a suction ring in rabbits.

Authors:  Spyridon K Charisis; Harilaos S Ginis; Georgios A Kounis; Miltiadis K Tsilimbaris
Journal:  BMC Ophthalmol       Date:  2008-07-30       Impact factor: 2.209

  5 in total