Literature DB >> 18299836

Real-time MR fluoroscopy-navigated lumbar facet joint injections: feasibility and technical properties.

J Fritz1, S Clasen, A Boss, C Thomas, C W König, C D Claussen, P L Pereira.   

Abstract

We prospectively evaluated the feasibility and technical properties of a dedicated interventional magnetic resonance (MR) imaging protocol for near-real-time MR fluoroscopy-guided bilateral lumbar facet joint injections. A total of 44 facet joint injections were performed in 22 patients using a C-shaped open 0.2-T MR imaging system (Magnetom Concerto, Siemens Medical Solutions, Erlangen, Germany). A T1/T2-weighted fast-imaging-with-steady-precession (FISP) sequence with an end-to-end latency of 1.2 s facilitated sufficient near real-time MR imaging guidance in all cases. A T1-weighted two dimensional fast-low-angle-shot (FLASH2D) MR sequence identified final needle tip location. Different angles of the needle path had only minimal influence on the appearance of the needle artifact produced by both sequences, resulting in a symmetrical needle tip artifact. The joint cavity was successfully punctured in 79.5% (35/44) of joints, which was followed by intra-articular fluid accumulation in 75% (33/44). Inaccessible joints demonstrated a significantly (p=0.044) higher number of posterior osteophytes (66.7%, 6/9 joints) compared to accessible joints (26%, 9/35 joints). No complications occurred. Table time showed significant shortening over time with average table time of 33 (21-68.5) min. We conclude that MR fluoroscopy-navigated lumbar facet joint injections are feasible and safe.

Entities:  

Mesh:

Year:  2008        PMID: 18299836     DOI: 10.1007/s00330-008-0890-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  21 in total

1.  Interventional MR imaging for injection of sacroiliac joints in patients with sacroiliitis.

Authors:  P L Pereira; I Günaydin; J Trübenbach; F Dammann; C T Remy; I Kötter; F Schick; C W Koenig; C D Claussen
Journal:  AJR Am J Roentgenol       Date:  2000-07       Impact factor: 3.959

2.  Describing data: statistical and graphical methods.

Authors:  Seema S Sonnad
Journal:  Radiology       Date:  2002-12       Impact factor: 11.105

3.  Percutaneous MR-guided discography in a low-field system using optical instrument tracking: a feasibility study.

Authors:  Roberto Blanco Sequeiros; Rauli Klemola; Risto Ojala; Lasse Jyrkinen; Teuvo Vaara; Osmo Tervonen
Journal:  J Magn Reson Imaging       Date:  2003-02       Impact factor: 4.813

Review 4.  Interventional and intraoperative MR: review and update of techniques and clinical experience.

Authors:  Thomas Schulz; Silvia Puccini; Jens-Peter Schneider; Thomas Kahn
Journal:  Eur Radiol       Date:  2004-10-06       Impact factor: 5.315

5.  An interactive taxonomy of MR imaging sequences.

Authors:  Gerard E Boyle; Mary Ahern; Jennie Cooke; Niall P Sheehy; James F Meaney
Journal:  Radiographics       Date:  2006 Nov-Dec       Impact factor: 5.333

Review 6.  The value of fat saturation sequences and contrast medium administration in MRI of degenerative disease of the posterior/perispinal elements of the lumbosacral spine.

Authors:  P D'Aprile; A Tarantino; J R Jinkins; D Brindicci
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

7.  Interactive MR imaging-guided biopsy and aspiration with a modified clinical C-arm system.

Authors:  J S Lewin; C A Petersilge; S F Hatem; J L Duerk; G Lenz; M E Clampitt; M L Williams; K R Kaczynski; C F Lanzieri; A L Wise; J R Haaga
Journal:  AJR Am J Roentgenol       Date:  1998-06       Impact factor: 3.959

8.  Value of CT fluoroscopy for lumbar facet blocks.

Authors:  Sherif Meleka; Ajanta Patra; Evan Minkoff; Kieran Murphy
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

9.  MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results.

Authors:  Stephan Zangos; Katrin Eichler; Kerstin Engelmann; Mukhtiar Ahmed; Sebastian Dettmer; Christopher Herzog; Wasilios Pegios; A Wetter; Thomas Lehnert; Martin G Mack; Thomas J Vogl
Journal:  Eur Radiol       Date:  2004-09-04       Impact factor: 5.315

10.  Computed tomography and fluoroscopy guided anesthesia and steroid injection in facet syndrome.

Authors:  F R Murtagh
Journal:  Spine (Phila Pa 1976)       Date:  1988-06       Impact factor: 3.468

View more
  11 in total

1.  MRI guidance technology development in a large animal model for hyperlocal analgesics delivery to the epidural space and dorsal root ganglion.

Authors:  Timothy P Maus; Joel P Felmlee; Mark D Unger; Andreas S Beutler
Journal:  J Neurosci Methods       Date:  2018-12-01       Impact factor: 2.390

2.  MRI-guided percutaneous nephrostomy: a feasibility study.

Authors:  Juho Kariniemi; Roberto Blanco Sequeiros; Risto Ojala; Osmo Tervonen
Journal:  Eur Radiol       Date:  2008-11-26       Impact factor: 5.315

3.  MR-guided facet joint injection therapy using an open 1.0-T MRI system: an outcome study.

Authors:  Patrick Freyhardt; Tony Hartwig; Maximilian De Bucourt; Martin Maurer; Diane Renz; Bernhard Gebauer; Bernd Hamm; Ulf K M Teichgräber; Florian Streitparth
Journal:  Eur Radiol       Date:  2013-06-28       Impact factor: 5.315

4.  Evaluation of MR imaging guided steroid injection of the sacroiliac joints for the treatment of children with refractory enthesitis-related arthritis.

Authors:  J Fritz; N Tzaribachev; C Thomas; J A Carrino; C D Claussen; J S Lewin; P L Pereira
Journal:  Eur Radiol       Date:  2010-10-29       Impact factor: 5.315

5.  Real-time fusion-imaging in low back pain: a new navigation system for facet joint injections.

Authors:  Elena Massone; Davide Orlandi; Alberto Bellelli; Fabio Martino; Luca Cavagnaro; Matteo Formica; Pietro Caruso; Enzo Silvestri
Journal:  Radiol Med       Date:  2018-07-03       Impact factor: 3.469

6.  Augmented reality visualisation using an image overlay system for MR-guided interventions: technical performance of spine injection procedures in human cadavers at 1.5 Tesla.

Authors:  Jan Fritz; Paweena U-Thainual; Tamas Ungi; Aaron J Flammang; Gabor Fichtinger; Iulian I Iordachita; John A Carrino
Journal:  Eur Radiol       Date:  2012-07-15       Impact factor: 5.315

7.  [Lumbar CT-guided radiofrequency ablation of the medial branch of the dorsal ramus of the spinal nerve : Anatomic study and description of a new technique].

Authors:  G C Feigl; C Mattersberger; W Rosmarin; R Likar; C Avila González
Journal:  Schmerz       Date:  2018-04       Impact factor: 1.107

8.  Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: feasibility and technical features.

Authors:  F Streitparth; T Walter; U Wonneberger; S Chopra; F Wichlas; M Wagner; K G Hermann; B Hamm; U Teichgräber
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

Review 9.  Magnetic Resonance Imaging-Guided Spine Interventions.

Authors:  Nathan C Himes; Thanissara Chansakul; Thomas C Lee
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-07-06       Impact factor: 2.266

10.  In vivo feasibility of real-time MR-US fusion imaging lumbar facet joint injections.

Authors:  Riccardo Sartoris; Davide Orlandi; Angelo Corazza; Luca Maria Sconfienza; Alice Arcidiacono; Silvia Perugin Bernardi; Simone Schiaffino; Giovanni Turtulici; Pietro Caruso; Enzo Silvestri
Journal:  J Ultrasound       Date:  2017-01-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.