Literature DB >> 16374162

Predisposing factors for hypoglycemia in the intensive care unit.

Titia M Vriesendorp1, Susanne van Santen, J Hans DeVries, Evert de Jonge, Frits R Rosendaal, Marcus J Schultz, Joost B L Hoekstra.   

Abstract

OBJECTIVE: The introduction of strict glycemic control in the intensive care unit has increased the risk for hypoglycemia. In this study we examined the association between predefined circumstances and the occurrence of hypoglycemia in the intensive care unit.
DESIGN: : Retrospective cohort study.
SETTING: Academic medical center. PATIENTS: All episodes of hypoglycemia (glucose value <45 mg/dL) in our intensive care unit between September 2002 and September 2004 were identified. Presence of predefined circumstances previously associated with hypoglycemia was scored around the moment of hypoglycemia using a patient data management system and in-hospital charts. Patients with a first hypoglycemic event were contrasted to controls from the same cohort, who were matched for time since admission, to correct for the effect of length of stay. Data were analyzed using conditional logistic regression analysis.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Of 2,272 patients, 156 (6.9%) experienced at least one episode of hypoglycemia. Continuous venovenous hemofiltration with bicarbonate-based substitution fluid (odds ratio [OR], 14; 95% confidence interval [CI], 1.8-106), a decrease of nutrition without adjustment for insulin infusion (OR, 6.6; 95% CI, 1.9-23), diabetes mellitus (OR, 2.6; 95% CI, 1.5-4.7), insulin use (OR, 5.3; 95% CI, 2.8-11), sepsis (OR, 2.2; 95% CI, 1.2-4.1), and inotropic support (OR, 1.8; 95% CI, 1.1-2.9) were associated with hypoglycemia. Simultaneous octreotide and insulin use (OR, 6.0; 95% CI, 0.72-50) may also be associated with hypoglycemia. Gastric residual during enteral nutrition without adjusting insulin infusion, liver failure, continuous venovenous hemofiltration with lactate-based substitution fluid, diminished glomerular filtration rate, dose diminishment of glucocorticoids or catecholamines, and use of beta-blocking agents were not associated with hypoglycemia. Adjusting for age, gender, and Acute Physiology and Chronic Health Evaluation II score at admission did not materially change ORs.
CONCLUSION: Use of bicarbonate-based substitution fluid during continuous venovenous hemofiltration, a decrease of nutrition without adjustment for insulin infusion, a prior diagnosis of diabetes mellitus, sepsis, and need for inotropic support were found to be associated with hypoglycemia. Simultaneous use of insulin and octreotide may be associated with hypoglycemia.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16374162     DOI: 10.1097/01.ccm.0000194536.89694.06

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  65 in total

1.  Interface design and human factors considerations for model-based tight glycemic control in critical care.

Authors:  Logan Ward; James Steel; Aaron Le Compte; Alicia Evans; Chia-Siong Tan; Sophie Penning; Geoffrey M Shaw; Thomas Desaive; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2012-01-01

Review 2.  Anesthetic considerations in diabetic patients. Part II: intraoperative and postoperative management of patients with diabetes mellitus.

Authors:  Yuji Kadoi
Journal:  J Anesth       Date:  2010-07-17       Impact factor: 2.078

3.  Pre-morbid glycemic control modifies the interaction between acute hypoglycemia and mortality.

Authors:  Moritoki Egi; James S Krinsley; Paula Maurer; Devendra N Amin; Tomoyuki Kanazawa; Shruti Ghandi; Kiyoshi Morita; Michael Bailey; Rinaldo Bellomo
Journal:  Intensive Care Med       Date:  2016-02-03       Impact factor: 17.440

4.  Hypoglycemia and outcome in critically ill patients.

Authors:  Moritoki Egi; Rinaldo Bellomo; Edward Stachowski; Craig J French; Graeme K Hart; Gopal Taori; Colin Hegarty; Michael Bailey
Journal:  Mayo Clin Proc       Date:  2010-02-22       Impact factor: 7.616

5.  Provision of balanced nutrition protects against hypoglycemia in the critically ill surgical patient.

Authors:  Rondi M Kauffmann; Rachel M Hayes; Judith M Jenkins; Patrick R Norris; Jose J Diaz; Addison K May; Bryan R Collier
Journal:  JPEN J Parenter Enteral Nutr       Date:  2011-07-12       Impact factor: 4.016

Review 6.  Stress hyperglycaemia.

Authors:  Kathleen M Dungan; Susan S Braithwaite; Jean-Charles Preiser
Journal:  Lancet       Date:  2009-05-23       Impact factor: 79.321

7.  Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring.

Authors:  Ulrike Holzinger; Joanna Warszawska; Reinhard Kitzberger; Harald Herkner; Philipp G H Metnitz; Christian Madl
Journal:  Intensive Care Med       Date:  2009-04-07       Impact factor: 17.440

8.  Study of a structured action pathway and persistent monitoring tool among nurses to achieve cent percent management of hypoglycaemia in in-patients: A measure of quality of healthcare.

Authors:  Sandhya Mishra; Ashutosh Chauhan; Sudhir Jha
Journal:  Med J Armed Forces India       Date:  2016-01-04

9.  Accuracy of bedside capillary blood glucose measurements in critically ill patients.

Authors:  C Dana Critchell; Vincent Savarese; Amy Callahan; Christine Aboud; Serge Jabbour; Paul Marik
Journal:  Intensive Care Med       Date:  2007-09-01       Impact factor: 17.440

10.  Risk factors for hypoglycaemia in neurocritical care patients.

Authors:  Freya M van Iersel; Arjen J C Slooter; Renee Vroegop; Annemiek E Wolters; Charlotte A M Tiemessen; Rik H J Rösken; Johannes G van der Hoeven; Linda M Peelen; Cornelia W E Hoedemaekers
Journal:  Intensive Care Med       Date:  2012-08-21       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.