Literature DB >> 18295454

Cortical bone thickness in the buccal posterior region for orthodontic mini-implants.

A Ono1, M Motoyoshi, N Shimizu.   

Abstract

The aim of this study was to investigate cortical bone thickness in the buccal posterior region mesial and distal to the first molar, where mini-implants are often placed, and determine any differences according to location, age and sex. The subjects were 43 patients who had mini-implants placed in the posterior buccal alveolar bone as anchors for orthodontic treatment. Computed tomography was used for diagnostic imaging of the area surrounding the site of implant placement. Cortical bone thickness was measured from 1 to 15 mm below the alveolar crest at 1-mm intervals. The average cortical bone thicknesses ranged from 1.09 to 2.12 mm in the maxilla and 1.59 to 3.03 mm in the mandible. The greater the height, the thicker the cortical bone tended to be, and the mandibular cortical bone was significantly thicker than that of the maxilla. The cortical bone was thinner in females than in males in the region of attached gingiva in the maxilla mesial to the first molar. The mandible suffices as a preparation site for mini-implants, while the maxilla might be insufficient at shallow locations. Regardless of age, the initial stability of mini-implants in shallow locations in the maxilla of women should be considered.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18295454     DOI: 10.1016/j.ijom.2008.01.005

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  25 in total

1.  Craniofacial growth patterns in patients with congenitally missing permanent teeth.

Authors:  Natascha Bauer; Katinka Heckmann; Andrea Sand; Jörg A Lisson
Journal:  J Orofac Orthop       Date:  2009-03-26       Impact factor: 1.938

2.  Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement.

Authors:  Hong Zhao; Xiao-Ming Gu; Hong-Chen Liu; Zhao-Wu Wang; Chun-Lei Xun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-04-17

3.  A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition.

Authors:  Mayur S Bhattad; Sudhindra Baliga; Pavan Vibhute
Journal:  Dental Press J Orthod       Date:  2015 Mar-Apr

4.  Buccal cortical bone thickness at miniscrew placement sites in patients with different vertical skeletal patterns.

Authors:  Ilknur Veli; Tancan Uysal; Asli Baysal; Irfan Karadede
Journal:  J Orofac Orthop       Date:  2014-10-26       Impact factor: 1.938

5.  Maxillary sinus size and posterior tooth inclination in Japanese orthodontic patients with agenesis of maxillary second premolars.

Authors:  Yui Kabasawa; Yoshiko Seto-Sugiki; Toshiya Endo
Journal:  Odontology       Date:  2019-10-03       Impact factor: 2.634

6.  A CBCT atlas of buccal cortical bone thickness in interradicular spaces.

Authors:  Patrick B Holmes; Bethany J Wolf; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

7.  Factors affecting stresses in cortical bone around miniscrew implants: a three-dimensional finite element study.

Authors:  Ramzi Duaibis; Budi Kusnoto; Raghu Natarajan; Linping Zhao; Carla Evans
Journal:  Angle Orthod       Date:  2012-03-05       Impact factor: 2.079

8.  Effects of cortical bone thickness at different healing times on microscrew stability.

Authors:  Xing Wei; Lixing Zhao; Zhenrui Xu; Tian Tang; Zhihe Zhao
Journal:  Angle Orthod       Date:  2011-05-02       Impact factor: 2.079

9.  Optimal sites for orthodontic mini-implant placement assessed by cone beam computed tomography.

Authors:  Mona Mohamed Salah Fayed; Pawel Pazera; Christos Katsaros
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

10.  Effects of screw and host factors on insertion torque and pullout strength.

Authors:  Ankit H Shah; Rolf G Behrents; Ki Beom Kim; Hee-Moon Kyung; Peter H Buschang
Journal:  Angle Orthod       Date:  2012-07       Impact factor: 2.079

View more