Literature DB >> 18280194

Site-specific variation of bone micro-architecture in the distal radius and tibia.

Steven K Boyd1.   

Abstract

High-resolution peripheral quantitative computed tomography measures 3-dimensional bone micro-architecture at the distal radius and tibia, and provides new insight issues of bone quality in patients. The typical measurement region of interest (ROI) with an axial dimension of 9.02 mm is positioned at a fixed distance from landmarks at the distal end of the radius or tibia, but little is known about the variation of bone architecture in the vicinity of this region and related sensitivity to measurement location. Variation in ROI position can lead to differences in quantitative outcomes, and this is compounded when reference landmarks are difficult for an operator to discern. Therefore, the purpose of this study was to quantify the site-specific variation in bone micro-architecture at the human distal radius and tibia, and the impact of variation of the ROI position. Using cadavers, a 27.06-mm axial ROI including the typical clinical measurement site was scanned, and the variation of morphological (apparent density, trabecular density, trabecular number, and cortical thickness) and biomechanical (polar moment of inertia, cross-sectional area) indices were assessed along the 27.06 mm length. It was found that the radius has more site-specific variation than the tibia. Furthermore, the shifting of the 9.02 mm clinical ROI position by +/-0.5mm resulted in approximately a 2% and 6% error in the tibia and radius density, respectively. For longitudinal assessment of bone architecture, site-specific variation is not as critical because comparisons are made within an individual; however, site-specific variation is an important consideration for cross-section studies and assessment of individuals against a normative population database.

Entities:  

Mesh:

Year:  2008        PMID: 18280194     DOI: 10.1016/j.jocd.2007.12.013

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.617


  37 in total

1.  Effect of oral monthly ibandronate on bone microarchitecture in women with osteopenia-a randomized placebo-controlled trial.

Authors:  R D Chapurlat; M Laroche; T Thomas; S Rouanet; P D Delmas; M-C de Vernejoul
Journal:  Osteoporos Int       Date:  2012-03-09       Impact factor: 4.507

2.  Radiological diagnostic progress in skeletal diseases.

Authors:  Giuseppe Guglielmi; Michelangelo Nasuto; Michele La Porta
Journal:  Clin Cases Miner Bone Metab       Date:  2011-01

3.  Using 3D image registration to maximize the reproducibility of longitudinal bone strength assessment by HR-pQCT and finite element analysis.

Authors:  R M Plett; T D Kemp; L A Burt; E O Billington; D A Hanley; S K Boyd
Journal:  Osteoporos Int       Date:  2021-02-24       Impact factor: 4.507

4.  Alterations of bone microstructure and strength in end-stage renal failure.

Authors:  A Trombetti; C Stoermann; T Chevalley; B Van Rietbergen; F R Herrmann; P-Y Martin; R Rizzoli
Journal:  Osteoporos Int       Date:  2012-10-26       Impact factor: 4.507

Review 5.  High-resolution in vivo imaging of bone and joints: a window to microarchitecture.

Authors:  Piet Geusens; Roland Chapurlat; Georg Schett; Ali Ghasem-Zadeh; Ego Seeman; Joost de Jong; Joop van den Bergh
Journal:  Nat Rev Rheumatol       Date:  2014-03-04       Impact factor: 20.543

6.  Operator variability in scan positioning is a major component of HR-pQCT precision error and is reduced by standardized training.

Authors:  S Bonaretti; N Vilayphiou; C M Chan; A Yu; K Nishiyama; D Liu; S Boutroy; A Ghasem-Zadeh; S K Boyd; R Chapurlat; H McKay; E Shane; M L Bouxsein; D M Black; S Majumdar; E S Orwoll; T F Lang; S Khosla; A J Burghardt
Journal:  Osteoporos Int       Date:  2016-07-30       Impact factor: 4.507

7.  3-D X-Ray-Induced Acoustic Computed Tomography With a Spherical Array: A Simulation Study on Bone Imaging.

Authors:  Yang Li; Pratik Samant; Siqi Wang; A Behrooz; Dengwang Li; Liangzhong Xiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-04-06       Impact factor: 2.725

8.  Young adults with cystic fibrosis have altered trabecular microstructure by ITS-based morphological analysis.

Authors:  M S Putman; L B Greenblatt; L Sicilian; A Uluer; A Lapey; G Sawicki; C M Gordon; M L Bouxsein; J S Finkelstein
Journal:  Osteoporos Int       Date:  2016-03-07       Impact factor: 4.507

9.  Multicenter precision of cortical and trabecular bone quality measures assessed by high-resolution peripheral quantitative computed tomography.

Authors:  Andrew J Burghardt; Jean-Baptiste Pialat; Galateia J Kazakia; Stephanie Boutroy; Klaus Engelke; Janina M Patsch; Alexander Valentinitsch; Danmei Liu; Eva Szabo; Cesar E Bogado; Maria Belen Zanchetta; Heather A McKay; Elizabeth Shane; Steven K Boyd; Mary L Bouxsein; Roland Chapurlat; Sundeep Khosla; Sharmila Majumdar
Journal:  J Bone Miner Res       Date:  2013-03       Impact factor: 6.741

10.  Patient-specific bone modelling and remodelling simulation of hypoparathyroidism based on human iliac crest biopsies.

Authors:  Patrik Christen; Keita Ito; Ralph Müller; Mishaela R Rubin; David W Dempster; John P Bilezikian; Bert van Rietbergen
Journal:  J Biomech       Date:  2012-08-09       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.