Literature DB >> 18270060

Single and multipinhole collimator design evaluation method for small animal SPECT.

K Vunckx1, D Beque, M Defrise, J Nuyts.   

Abstract

High-resolution functional imaging of small animals is often obtained by single pinhole SPECT with circular orbit acquisition. Multipinhole SPECT adds information due to its improved sampling, and can improve the trade-off between resolution and sensitivity. To evaluate different pinhole collimator designs an efficient method is needed that quantifies the reconstruction image quality. In this paper, we propose a fast, approximate method that examines the quality of individual voxels of a postsmoothed maximum likelihood expectation maximization (MLEM) reconstruction by studying their linearized local impulse response (LLIR) and (co)variance for a predefined target resolution. For validation, the contrast-to-noise ratios (CNRs) in some voxels of a homogeneous sphere and of a realistic rat brain software phantom were calculated for many single and multipinhole designs. A good agreement was observed between the CNRs obtained with the approximate method and those obtained with postsmoothed MLEM reconstructions of simulated noisy projections. This good agreement was quantified by a least squares fit through these results, which yielded a line with slope 1.02 (1.00 expected) and a y-intercept close to zero (0 expected). 95.4% of the validation points lie within three standard deviations from that line. Using the approximate method, the influence on the CNR of varying a parameter in realistic single and multipinhole designs was examined. The investigated parameters were the aperture diameter, the distance between the apertures and the axis-of-rotation, the focal distance, the acceptance angle, the position of the apertures, the focusing distance, and the number of pinholes. The results can generally be explained by the change in sensitivity, the amount of postsmoothing, and the amount of overlap in the projections. The method was applied to multipinhole designs with apertures focusing at a single point, but is also applicable to other designs.

Entities:  

Mesh:

Year:  2008        PMID: 18270060     DOI: 10.1109/TMI.2007.902802

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  13 in total

1.  A SPECT imager with synthetic collimation.

Authors:  Ronan J Havelin; Brian W Miller; Harrison H Barrett; Lars R Furenlid; J M Murphy; Mark J Foley
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-08-25

Review 2.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

3.  Detection performance analysis for time-of-flight PET.

Authors:  Nannan Cao; Ronald H Huesman; William W Moses; Jinyi Qi
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

4.  Quantification of the Multiplexing Effects in Multi-Pinhole Small Animal SPECT: A Simulation Study.

Authors:  Greta S P Mok; Yuchuan Wang; Benjamin M W Tsui
Journal:  IEEE Trans Nucl Sci       Date:  2009       Impact factor: 1.679

5.  MR-based keyhole SPECT for small animal imaging.

Authors:  Keum Sil Lee; Werner W Roeck; Grant T Gullberg; Orhan Nalcioglu
Journal:  Phys Med Biol       Date:  2011-01-10       Impact factor: 3.609

6.  Multipinhole collimator with 20 apertures for a brain SPECT application.

Authors:  Tzu-Cheng Lee; Justin R Ellin; Qiu Huang; Uttam Shrestha; Grant T Gullberg; Youngho Seo
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

7.  Preclinical imaging of therapy response using metabolic and apoptosis molecular imaging.

Authors:  Marijke De Saint-Hubert; Huijun Wang; Ellen Devos; Kathleen Vunckx; Lin Zhou; Chris Reutelingsperger; Alfons Verbruggen; Luc Mortelmans; Yicheng Ni; Felix M Mottaghy
Journal:  Mol Imaging Biol       Date:  2011-10       Impact factor: 3.488

8.  Design and performance of a small-animal imaging system using synthetic collimation.

Authors:  R J Havelin; B W Miller; H H Barrett; L R Furenlid; J M Murphy; R M Dwyer; M J Foley
Journal:  Phys Med Biol       Date:  2013-04-26       Impact factor: 3.609

9.  Fisher information-based evaluation of image quality for time-of-flight PET.

Authors:  Kathleen Vunckx; Lin Zhou; Samuel Matej; Michel Defrise; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2009-08-25       Impact factor: 10.048

10.  Design and performance evaluation of a 20-aperture multipinhole collimator for myocardial perfusion imaging applications.

Authors:  Jason D Bowen; Qiu Huang; Justin R Ellin; Tzu-Cheng Lee; Uttam Shrestha; Grant T Gullberg; Youngho Seo
Journal:  Phys Med Biol       Date:  2013-09-24       Impact factor: 3.609

View more