Literature DB >> 24061162

Design and performance evaluation of a 20-aperture multipinhole collimator for myocardial perfusion imaging applications.

Jason D Bowen1, Qiu Huang, Justin R Ellin, Tzu-Cheng Lee, Uttam Shrestha, Grant T Gullberg, Youngho Seo.   

Abstract

Single photon emission computed tomography (SPECT) myocardial perfusion imaging remains a critical tool in the diagnosis of coronary artery disease. However, after more than three decades of use, photon detection efficiency remains poor and unchanged. This is due to the continued reliance on parallel-hole collimators first introduced in 1964. These collimators possess poor geometric efficiency. Here we present the performance evaluation results of a newly designed multipinhole collimator with 20 pinhole apertures (PH20) for commercial SPECT systems. Computer simulations and numerical observer studies were used to assess the noise, bias and diagnostic imaging performance of a PH20 collimator in comparison with those of a low energy high resolution (LEHR) parallel-hole collimator. Ray-driven projector/backprojector pairs were used to model SPECT imaging acquisitions, including simulation of noiseless projection data and performing MLEM/OSEM image reconstructions. Poisson noise was added to noiseless projections for realistic projection data. Noise and bias performance were investigated for five mathematical cardiac and torso (MCAT) phantom anatomies imaged at two gantry orbit positions (19.5 and 25.0 cm). PH20 and LEHR images were reconstructed with 300 MLEM iterations and 30 OSEM iterations (ten subsets), respectively. Diagnostic imaging performance was assessed by a receiver operating characteristic (ROC) analysis performed on a single MCAT phantom; however, in this case PH20 images were reconstructed with 75 pixel-based OSEM iterations (four subsets). Four PH20 projection views from two positions of a dual-head camera acquisition and 60 LEHR projections were simulated for all studies. At uniformly-imposed resolution of 12.5 mm, significant improvements in SNR and diagnostic sensitivity (represented by the area under the ROC curve, or AUC) were realized when PH20 collimators are substituted for LEHR parallel-hole collimators. SNR improves by factors of 1.94-2.34 for the five patient anatomies and two orbital positions studied. For the ROC analysis the PH20 AUC is larger than the LEHR AUC with a p-value of 0.0067. Bias performance, however, decreases with the use of PH20 collimators. Systematic analyses showed PH20 collimators present improved diagnostic imaging performance over LEHR collimators, requiring only collimator exchange on existing SPECT cameras for their use.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24061162      PMCID: PMC3855225          DOI: 10.1088/0031-9155/58/20/7209

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  41 in total

1.  Pixel-based subsets for rapid multi-pinhole SPECT reconstruction.

Authors:  Woutjan Branderhorst; Brendan Vastenhouw; Freek J Beekman
Journal:  Phys Med Biol       Date:  2010-03-19       Impact factor: 3.609

2.  Cost-effectiveness of coronary CT angiography versus myocardial perfusion SPECT for evaluation of patients with chest pain and no known coronary artery disease.

Authors:  James K Min; Amanda Gilmore; Matthew J Budoff; Daniel S Berman; Ken O'Day
Journal:  Radiology       Date:  2010-03       Impact factor: 11.105

3.  Noise properties of the EM algorithm: II. Monte Carlo simulations.

Authors:  D W Wilson; B M Tsui; H H Barrett
Journal:  Phys Med Biol       Date:  1994-05       Impact factor: 3.609

4.  Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging--a simulation study.

Authors:  Zixiong Cao; Girish Bal; Roberto Accorsi; Paul D Acton
Journal:  Phys Med Biol       Date:  2005-09-21       Impact factor: 3.609

5.  Procedure guideline for myocardial perfusion imaging 3.3.

Authors:  H William Strauss; D Douglas Miller; Mark D Wittry; Manuel D Cerqueira; Ernest V Garcia; Abdulmassi S Iskandrian; Heinrich R Schelbert; Frans J Wackers; Helena R Balon; Otto Lang; Josef Machac
Journal:  J Nucl Med Technol       Date:  2008-08-14

Review 6.  Small animal imaging with multi-pinhole SPECT.

Authors:  Johan Nuyts; Kathleen Vunckx; Michel Defrise; Christian Vanhove
Journal:  Methods       Date:  2009-03-26       Impact factor: 3.608

7.  Value of stress myocardial perfusion single photon emission computed tomography in patients with normal resting electrocardiograms: an evaluation of incremental prognostic value and cost-effectiveness.

Authors:  Rory Hachamovitch; Daniel S Berman; Hosen Kiat; Ishac Cohen; John D Friedman; Leslee J Shaw
Journal:  Circulation       Date:  2002-02-19       Impact factor: 29.690

8.  Evaluation of image reconstruction for mouse brain imaging with synthetic collimation from highly multiplexed SiliSPECT projections.

Authors:  S Shokouhi; D W Wilson; S D Metzler; T E Peterson
Journal:  Phys Med Biol       Date:  2010-08-16       Impact factor: 3.609

9.  Incremental prognostic value of gated Rb-82 positron emission tomography myocardial perfusion imaging over clinical variables and rest LVEF.

Authors:  Sharmila Dorbala; Rory Hachamovitch; Zelmira Curillova; Deepak Thomas; Divya Vangala; Raymond Y Kwong; Marcelo F Di Carli
Journal:  JACC Cardiovasc Imaging       Date:  2009-07

10.  Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT.

Authors:  Timothy M Bateman; Gary V Heller; A Iain McGhie; John D Friedman; James A Case; Jan R Bryngelson; Ginger K Hertenstein; Kelly L Moutray; Kimberly Reid; S James Cullom
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

View more
  2 in total

1.  Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations.

Authors:  Yanfei Mao; Zhicong Yu; Gengsheng L Zeng
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

2.  Multipinhole collimator with 20 apertures for a brain SPECT application.

Authors:  Tzu-Cheng Lee; Justin R Ellin; Qiu Huang; Uttam Shrestha; Grant T Gullberg; Youngho Seo
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.