Literature DB >> 1826881

Reproducibility of quantitative hexakis-2-methoxyisobutylisonitrile single photon emission tomography in stable coronary artery disease.

M Milcinski1, E Henze, R Lietzenmayer, M Clausen, R Weller, V Hombach, W E Adam, M Porenta.   

Abstract

The quantification of myocardial perfusion abnormalities is necessary to allow comparison of repeated studies, especially in the evaluation of the success of medical, interventional or combined treatment in stable coronary artery disease or in evolving myocardial infarction. The purpose of this study was to assess inter-observer reproducibility of tomographic study processing using a semi-automatic quantitative programme. Technetium 99m hexakis-2-methoxyisobutylisonitrile (99mTc-Sestamibi) was chosen for tomographic imaging of repeated rest-stress studies in patients with stable coronary artery disease. The quantification was performed using a modification of the Cedars polar coding and comparison with the normal data base. The perfusion defects were quantified separately for each standard perfusion area [left anterior descending (LAD), right coronary (RCA) and left circumflex (LCX) arteries] and total area of hypoperfused myocardium. The inter-observer variability for 40 tomographic studies was accomplished. The defects were the largest in the LAD perfusion area (average 19.7% of the normalized LAD supply area) with an inter-observer correlation of 0.84 for this region. The greatest variability was found for the LCX region (r = 0.55) and is attributed to a small average perfusion defect (7.1%), only 18 studies having abnormal perfusion in this area. In total, an average 14.3% of the left ventricular myocardium was significantly hypoperfused, and the inter-observer correlation was 0.87. These results show good inter-observer reproducibility using semi-automatic quantitation of perfusion defects. Careful interpretation of smaller defects in the evaluation of treatment results is advised when repeated 99mTc-Sestamibi single photon emission tomography studies are processed by more than one observer.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1826881     DOI: 10.1007/bf00177679

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  12 in total

1.  Quantitative rotational tomography with 201Tl and 99mTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease.

Authors:  J K Kahn; I McGhie; M S Akers; M N Sills; T L Faber; P V Kulkarni; J T Willerson; J R Corbett
Journal:  Circulation       Date:  1989-06       Impact factor: 29.690

2.  Myocardial kinetics of 99Tcm hexakis-(2-methoxy-isobutyl-isonitrile) (HMIBI) in patients with coronary heart disease: a comparative study versus 201Tl with SPECT.

Authors:  H Stirner; U Buell; E Kleinhans; R Bares; W Grosse
Journal:  Nucl Med Commun       Date:  1988-01       Impact factor: 1.690

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis.

Authors:  D J Fintel; J M Links; J A Brinker; T L Frank; M Parker; L C Becker
Journal:  J Am Coll Cardiol       Date:  1989-03-01       Impact factor: 24.094

5.  Assessment of regurgitant fraction and right and left ventricular function at rest and during exercise: a new technique for determination of right ventricular stroke counts from gated equilibrium blood pool studies.

Authors:  E Henze; H R Schelbert; G Wisenberg; O Ratib; H Schön
Journal:  Am Heart J       Date:  1982-11       Impact factor: 4.749

6.  Quantification of rotational thallium-201 myocardial tomography.

Authors:  E V Garcia; K Van Train; J Maddahi; F Prigent; J Friedman; J Areeda; A Waxman; D S Berman
Journal:  J Nucl Med       Date:  1985-01       Impact factor: 10.057

7.  Comparison of technetium 99m methoxy isobutyl isonitrile and thallium 201 for evaluation of coronary artery disease by planar and tomographic methods.

Authors:  H Kiat; J Maddahi; L T Roy; K Van Train; J Friedman; K Resser; D S Berman
Journal:  Am Heart J       Date:  1989-01       Impact factor: 4.749

8.  The evaluation of ventricular function using gated myocardial imaging with Tc-99m MIBI.

Authors:  Y C Najm; A D Timmis; M N Maisey; S V Ellam; R Mistry; P V Curry; E Sowton
Journal:  Eur Heart J       Date:  1989-02       Impact factor: 29.983

9.  Use of technetium-99m isonitrile (RP-30A) in assessing left ventricular perfusion and function at rest and during exercise in coronary artery disease, and comparison with coronary arteriography and exercise thallium-201 SPECT imaging.

Authors:  A S Iskandrian; J Heo; B Kong; E Lyons; S Marsch
Journal:  Am J Cardiol       Date:  1989-08-01       Impact factor: 2.778

10.  Clinical comparison between thallium-201 and Tc-99m-methoxy isobutyl isonitrile (hexamibi) myocardial perfusion imaging for detection of coronary artery disease.

Authors:  R Taillefer; R Lambert; G Dupras; J Grégoire; J Léveillé; R Essiambre; D C Phaneuf
Journal:  Eur J Nucl Med       Date:  1989
View more
  1 in total

1.  Interhospital observer agreement in interpretation of exercise myocardial Tc-99m tetrofosmin SPECT studies.

Authors:  J Candell-Riera; C Santana-Boado; B Bermejo; L Armadans; J Castell; I Casáns; J Jurado; J Magriñá; J N de la Rosa
Journal:  J Nucl Cardiol       Date:  2001 Jan-Feb       Impact factor: 5.952