Estimation of mean frequency and variance of ultrasonic Doppler signal by using second-order autoregressive model.

Y B Ahn1, S B Park.   

Abstract

In order to estimate the mean frequency and variance of the diagnostic ultrasound Doppler signal in the presence of clutter noise, a new estimator using a second-order autoregressive (AR) model, called the AR estimator, is proposed. The sampled signal that contains information of both the Doppler signal and clutter is described by the second-order AR model with two poles. The mean frequency and variance of a unidirectional Doppler signal can be estimated, respectively, from the phase and the magnitude of the pole, with larger phase between the two poles. If the clutter is not completely rejected, all conventional estimators, including the autocorrelation (AC) estimator, result in erroneous estimations for the mean frequency and variance of the Doppler signal, whereas the AR estimator gives an accurate estimation. In the absence of clutter, however, the performance of both the AC and AR estimators are similar. If the blood flows in both directions in a sample volume and the clutter is rejected to the extent that it no longer obscures the Doppler signal, the proposed method can estimate simultaneously the mean frequencies and variances of both the forward and reverse blood flows. The performance of the proposed AR estimator was compared with that of the AC estimator by computer simulations and experiments, and it was found that when the number of available sampled data is small, the AR estimator does not require the use of a clutter filter, which simplifies Doppler signal detection.

Year:  1991        PMID: 18267572     DOI: 10.1109/58.79600

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Performance of short-time spectral parametric methods for reducing the variance of the Doppler ultrasound mean instantaneous frequency estimation.

Authors:  H Sava; L G Durand; G Cloutier
Journal:  Med Biol Eng Comput       Date:  1999-05       Impact factor: 2.602

Review 2.  Developments in cardiovascular ultrasound: Part 1: Signal processing and instrumentation.

Authors:  P J Fish; P R Hoskins; C Moran; W N McDicken
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

3.  Doppler OCT clutter rejection using variance minimization and offset extrapolation.

Authors:  Adil Akif; Konrad Walek; Collin Polucha; Jonghwan Lee
Journal:  Biomed Opt Express       Date:  2018-10-10       Impact factor: 3.732

4.  A time domain mean frequency estimation algorithm of two-dimensional real-time Doppler imaging system.

Authors:  N F Güler
Journal:  J Med Syst       Date:  1995-10       Impact factor: 4.460

5.  Comparison of Kasai autocorrelation and maximum likelihood estimators for Doppler optical coherence tomography.

Authors:  Aaron C Chan; Edmund Y Lam; Vivek J Srinivasan
Journal:  IEEE Trans Med Imaging       Date:  2013-02-21       Impact factor: 10.048

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.