Megavoltage cone beam digital tomosynthesis (MV-CBDT) for image-guided radiotherapy: a clinical investigational system.

G Pang1, A Bani-Hashemi, P Au, P F O'Brien, J A Rowlands, G Morton, T Lim, P Cheung, A Loblaw.   

Abstract

Cone beam digital tomosynthesis (CBDT) is a new imaging technique proposed recently as a rapid approach for creating tomographic images of a patient in the radiotherapy treatment room. The purpose of this work is to investigate the feasibility of performing megavoltage (MV) CBDT clinically. A clinical investigational MV-CBDT system was installed on an existing LINAC. After the installation, the treatment machine can be operated in two distinct modes: (1) normal clinical treatment mode; (2) CBDT mode, in which tomographic images of the patient can be obtained using MV-CBDT. Various calibration and phantom measurements were performed on the system, followed by a patient study. Our phantom measurements have shown that: (1) for the same imaging dose, MV-CBDT has the same signal-difference-to-noise ratio as megavoltage cone beam computed tomography (MV-CBCT); (2) MV-CBDT has a better spatial resolution than MV-CBCT in the planes of reconstruction but a worse spatial resolution in the direction perpendicular to the planes of reconstruction. MV-CBDT patient images were also obtained and compared to that of MV-CBCT. We have demonstrated that it is clinically feasible to perform MV-CBDT in the treatment room for image-guided radiotherapy.

Entities:  

Mesh:

Year:  2008        PMID: 18263954     DOI: 10.1088/0031-9155/53/4/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Accuracy estimation for projection-to-volume targeting during rotational therapy: a feasibility study.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose.

Authors:  Yi Wang; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Louis Perna
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

Review 3.  Tomosynthesis imaging: at a translational crossroads.

Authors:  James T Dobbins
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

4.  Evaluation of respiration-correlated digital tomosynthesis in lung.

Authors:  Joseph Santoro; Sergey Kriminski; D Michael Lovelock; Kenneth Rosenzweig; Hassan Mostafavi; Howard I Amols; Gig S Mageras
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

5.  Clinical evaluation of positioning verification using digital tomosynthesis and bony anatomy and soft tissues for prostate image-guided radiotherapy.

Authors:  Sua Yoo; Q Jackie Wu; Devon Godfrey; Hui Yan; Lei Ren; Shiva Das; William R Lee; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-01-01       Impact factor: 7.038

6.  Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM3PARE): method comparison algorithm implementation for head and neck IGRT positional verification.

Authors:  Anuradha Roy; Clifton D Fuller; David I Rosenthal; Charles R Thomas
Journal:  BMC Med Imaging       Date:  2015-08-28       Impact factor: 1.930

7.  Simultaneous MV-kV imaging for intrafractional motion management during volumetric-modulated arc therapy delivery.

Authors:  Margie A Hunt; Mark Sonnick; Hai Pham; Rajesh Regmi; Jian-ping Xiong; Daniel Morf; Gig S Mageras; Michael Zelefsky; Pengpeng Zhang
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.