Literature DB >> 18263949

Vibration safety limits for magnetic resonance elastography.

E C Ehman1, P J Rossman, S A Kruse, A V Sahakian, K J Glaser.   

Abstract

Magnetic resonance elastography (MRE) has been demonstrated to have potential as a clinical tool for assessing the stiffness of tissue in vivo. An essential step in MRE is the generation of acoustic mechanical waves within a tissue via a coupled mechanical driver. Motivated by an increasing volume of human imaging trials using MRE, the objectives of this study were to audit the vibration amplitude of exposure for our IRB-approved human MRE studies, to compare these values to a conservative regulatory standard for vibrational exposure and to evaluate the applicability and implications of this standard for MRE. MRE displacement data were examined from 29 MRE exams, including the liver, brain, kidney, breast and skeletal muscle. Vibrational acceleration limits from a European Union directive limiting occupational exposure to whole-body and extremity vibrations (EU 2002/44/EC) were adjusted for time and frequency of exposure, converted to maximum displacement values and compared to the measured in vivo displacements. The results indicate that the vibrational amplitudes used in MRE studies are below the EU whole-body vibration limit, and the EU guidelines represent a useful standard that could be readily accepted by Institutional Review Boards to define standards for vibrational exposures for MRE studies in humans.

Entities:  

Mesh:

Year:  2008        PMID: 18263949      PMCID: PMC2868320          DOI: 10.1088/0031-9155/53/4/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Electromagnetic actuator for generating variably oriented shear waves in MR elastography.

Authors:  Juergen Braun; Karl Braun; Ingolf Sack
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

2.  Dose-response patterns for vibration-induced white finger.

Authors:  M J Griffin; M Bovenzi; C M Nelson
Journal:  Occup Environ Med       Date:  2003-01       Impact factor: 4.402

3.  Hand muscle pathology after long-term vibration exposure.

Authors:  Lars E Necking; Göran Lundborg; Ronnie Lundström; Lars-Eric Thornell; Jan Fridén
Journal:  J Hand Surg Br       Date:  2004-10

4.  Acute effects of continuous and intermittent vibration on finger circulation.

Authors:  Massimo Bovenzi; Alexandra J L Welsh; Michael J Griffin
Journal:  Int Arch Occup Environ Health       Date:  2004-03-18       Impact factor: 3.015

5.  Magnetic resonance elastography of skeletal muscle.

Authors:  M A Dresner; G H Rose; P J Rossman; R Muthupillai; A Manduca; R L Ehman
Journal:  J Magn Reson Imaging       Date:  2001-02       Impact factor: 4.813

6.  Magnetic resonance elastography: non-invasive mapping of tissue elasticity.

Authors:  A Manduca; T E Oliphant; M A Dresner; J L Mahowald; S A Kruse; E Amromin; J P Felmlee; J F Greenleaf; R L Ehman
Journal:  Med Image Anal       Date:  2001-12       Impact factor: 8.545

7.  Vibration-induced muscle fatigue, a possible contribution to musculoskeletal injury.

Authors:  Diane E Adamo; Bernard J Martin; Peter W Johnson
Journal:  Eur J Appl Physiol       Date:  2002-08-27       Impact factor: 3.078

Review 8.  The effects of whole body vibration on humans: dangerous or advantageous?

Authors:  M Cardinale; M H Pope
Journal:  Acta Physiol Hung       Date:  2003

9.  Prolonged muscle vibration reduces maximal voluntary knee extension performance in both the ipsilateral and the contralateral limb in man.

Authors:  Stephen W Jackson; Duncan L Turner
Journal:  Eur J Appl Physiol       Date:  2002-11-01       Impact factor: 3.078

10.  Prevention of postmenopausal bone loss by a low-magnitude, high-frequency mechanical stimuli: a clinical trial assessing compliance, efficacy, and safety.

Authors:  Clinton Rubin; Robert Recker; Diane Cullen; John Ryaby; Joan McCabe; Kenneth McLeod
Journal:  J Bone Miner Res       Date:  2003-12-22       Impact factor: 6.741

View more
  15 in total

Review 1.  Noncontrast functional MRI of the kidneys.

Authors:  Lorenzo Mannelli; Jeffrey H Maki; Sherif F Osman; Hersh Chandarana; David J Lomas; William P Shuman; Ken F Linnau; Douglas E Green; Giacomo Laffi; Miriam Moshiri
Journal:  Curr Urol Rep       Date:  2012-02       Impact factor: 3.092

2.  Magnetic Resonance Elastography.

Authors:  Daniel V Litwiller; Yogesh K Mariappan; Richard L Ehman
Journal:  Curr Med Imaging Rev       Date:  2012

3.  MR elastography derived shear stiffness--a new imaging biomarker for the assessment of early tumor response to chemotherapy.

Authors:  Kay M Pepin; Jun Chen; Kevin J Glaser; Yogesh K Mariappan; Brian Reuland; Steven Ziesmer; Rickey Carter; Stephen M Ansell; Richard L Ehman; Kiaran P McGee
Journal:  Magn Reson Med       Date:  2013-06-25       Impact factor: 4.668

Review 4.  Magnetic resonance elastography: a review.

Authors:  Yogesh K Mariappan; Kevin J Glaser; Richard L Ehman
Journal:  Clin Anat       Date:  2010-07       Impact factor: 2.414

Review 5.  Stiffness and Beyond: What MR Elastography Can Tell Us About Brain Structure and Function Under Physiologic and Pathologic Conditions.

Authors:  Ziying Yin; Anthony J Romano; Armando Manduca; Richard L Ehman; John Huston
Journal:  Top Magn Reson Imaging       Date:  2018-10

6.  Quantification of abdominal aortic aneurysm stiffness using magnetic resonance elastography and its comparison to aneurysm diameter.

Authors:  Arunark Kolipaka; Venkata Sita Priyanka Illapani; William Kenyhercz; Joshua D Dowell; Michael R Go; Jean E Starr; Patrick S Vaccaro; Richard D White
Journal:  J Vasc Surg       Date:  2016-04-27       Impact factor: 4.268

Review 7.  Magnetic resonance elastography (MRE) in cancer: Technique, analysis, and applications.

Authors:  Kay M Pepin; Richard L Ehman; Kiaran P McGee
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2015-06-23       Impact factor: 9.795

8.  Magnetic resonance elastography of the brain using multishot spiral readouts with self-navigated motion correction.

Authors:  Curtis L Johnson; Matthew D J McGarry; Elijah E W Van Houten; John B Weaver; Keith D Paulsen; Bradley P Sutton; John G Georgiadis
Journal:  Magn Reson Med       Date:  2012-09-21       Impact factor: 4.668

9.  High-frequency mode conversion technique for stiff lesion detection with magnetic resonance elastography (MRE).

Authors:  Yogesh K Mariappan; Kevin J Glaser; Armando Manduca; Anthony J Romano; Sudhakar K Venkatesh; Meng Yin; Richard L Ehman
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

10.  Slip Interface Imaging Predicts Tumor-Brain Adhesion in Vestibular Schwannomas.

Authors:  Ziying Yin; Kevin J Glaser; Armando Manduca; Jamie J Van Gompel; Michael J Link; Joshua D Hughes; Anthony Romano; Richard L Ehman; John Huston
Journal:  Radiology       Date:  2015-08-06       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.