Literature DB >> 18258709

Head-to-head comparison of the Lyon Schuss and fixed flexion radiographic techniques. Long-term reproducibility in normal knees and sensitivity to change in osteoarthritic knees.

M-P Hellio Le Graverand1, E P Vignon, K D Brandt, S A Mazzuca, M Piperno, R Buck, H C Charles, D J Hunter, C G Jackson, V Byers Kraus, T M Link, T J Schnitzer, A Vaz, B Wyman.   

Abstract

OBJECTIVE: The Lyon Schuss (LS) and fixed flexion (FF) views of the knee are superior to a conventional standing anteroposterior view in evaluating joint space narrowing (JSN) in osteoarthritis (OA). Both position the knee identically but only the LS aligns the medial tibial plateau (MTP) with the x-ray beam fluoroscopically. The present study provides the first head-to-head comparison of the LS and FF views.
METHODS: At baseline and 12 months, 62 OA and 99 control knees were imaged twice on the same day with LS and FF views. Minimum joint space width (mJSW) was measured by computer and MTP alignment was assessed from the distance between anterior and posterior margins of the MTP (intermargin distance, IMD). Reproducibility of measurements of mJSW and sensitivity to change were evaluated.
RESULTS: In normal knees, JSW did not vary over 12 months with either view. In OA knees, 12-month mJSN was 0.22 (0.43) mm with the LS view and -0.01 (0.46) mm with the FF view (p = 0.0002 and p = 0.92, respectively). Mean IMD was only half as large in LS as in FF views (0.9 (0.5) mm vs 1.9 (1.2) mm, p<0.0001).
CONCLUSIONS: LS and FF radiographs offer similar reproducibility in JSW measurement. However, presumably due to its superiority in aligning the MTP, the LS view is much more sensitive to JSN in OA knees.

Entities:  

Mesh:

Year:  2008        PMID: 18258709     DOI: 10.1136/ard.2007.077834

Source DB:  PubMed          Journal:  Ann Rheum Dis        ISSN: 0003-4967            Impact factor:   19.103


  25 in total

1.  The relationship between prevalent medial meniscal intrasubstance signal changes and incident medial meniscal tears in women over a 1-year period assessed with 3.0 T MRI.

Authors:  Michel D Crema; David J Hunter; Frank W Roemer; Ling Li; Monica D Marra; Marcello H Nogueira-Barbosa; Marie-Pierre Hellio Le Graverand; Bradley T Wyman; Ali Guermazi
Journal:  Skeletal Radiol       Date:  2011-05-08       Impact factor: 2.199

2.  Alignment of the medial tibial plateau affects the rate of joint space narrowing in the osteoarthritic knee.

Authors:  E Vignon; K D Brandt; C Mercier; M Hochberg; D Hunter; S Mazzuca; K Powell; B Wyman; M-P Hellio Le Graverand
Journal:  Osteoarthritis Cartilage       Date:  2010-09-08       Impact factor: 6.576

3.  Extrusion of the medial meniscus in knee osteoarthritis assessed with a rotating clino-orthostatic permanent-magnet MRI scanner.

Authors:  Francesco Paparo; Matteo Revelli; Riccardo Piccazzo; Davide Astengo; Dario Camellino; Matteo Puntoni; Alessandro Muda; Gian Andrea Rollandi; Giacomo Garlaschi; Marco Amedeo Cimmino
Journal:  Radiol Med       Date:  2014-08-13       Impact factor: 3.469

Review 4.  Imaging of cartilage and bone: promises and pitfalls in clinical trials of osteoarthritis.

Authors:  F Eckstein; A Guermazi; G Gold; J Duryea; M-P Hellio Le Graverand; W Wirth; C G Miller
Journal:  Osteoarthritis Cartilage       Date:  2014-10       Impact factor: 6.576

5.  Comparison of radiographic joint space width with magnetic resonance imaging cartilage morphometry: analysis of longitudinal data from the Osteoarthritis Initiative.

Authors:  Jeffrey Duryea; Gesa Neumann; Jingbo Niu; Saara Totterman; Jose Tamez; Christine Dabrowski; Marie-Pierre Hellio Le Graverand; Monica Luchi; Chan R Beals; David J Hunter
Journal:  Arthritis Care Res (Hoboken)       Date:  2010-07       Impact factor: 4.794

6.  One-year change in radiographic joint space width in patients with unilateral joint space narrowing: data from the Osteoarthritis Initiative.

Authors:  O D Benichou; D J Hunter; D R Nelson; A Guermazi; F Eckstein; K Kwoh; S L Myers; W Wirth; J Duryea
Journal:  Arthritis Care Res (Hoboken)       Date:  2010-07       Impact factor: 4.794

7.  Location specific radiographic joint space width for osteoarthritis progression.

Authors:  G Neumann; D Hunter; M Nevitt; L B Chibnik; K Kwoh; H Chen; T Harris; S Satterfield; J Duryea
Journal:  Osteoarthritis Cartilage       Date:  2008-11-12       Impact factor: 6.576

8.  Baseline and longitudinal change in isometric muscle strength prior to radiographic progression in osteoarthritic and pre-osteoarthritic knees--data from the Osteoarthritis Initiative.

Authors:  F Eckstein; W Hitzl; J Duryea; C Kent Kwoh; W Wirth
Journal:  Osteoarthritis Cartilage       Date:  2013-03-06       Impact factor: 6.576

9.  Magnetic resonance imaging-based cartilage loss in painful contralateral knees with and without radiographic joint space narrowing: Data from the Osteoarthritis Initiative.

Authors:  Felix Eckstein; Olivier Benichou; Wolfgang Wirth; David R Nelson; Susanne Maschek; Martin Hudelmaier; C Kent Kwoh; Ali Guermazi; David Hunter
Journal:  Arthritis Rheum       Date:  2009-09-15

10.  Relationship of compartment-specific structural knee status at baseline with change in cartilage morphology: a prospective observational study using data from the osteoarthritis initiative.

Authors:  Felix Eckstein; Wolfgang Wirth; Martin I Hudelmaier; Susanne Maschek; Wolfgang Hitzl; Bradley T Wyman; Michael Nevitt; Marie-Pierre Hellio Le Graverand; David Hunter
Journal:  Arthritis Res Ther       Date:  2009-06-17       Impact factor: 5.156

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.