Literature DB >> 18255107

Response of cats to familiar and unfamiliar human contact using continuous direct arterial blood pressure measurement.

L I Slingerland1, J H Robben, I Schaafsma, H S Kooistra.   

Abstract

Continuous direct measurement of feline arterial blood pressure (ABP) was carried out via a modified method with percutaneous, ultrasound guided catheterization of the common carotid artery. In 21 healthy, conscious cats the ABP was measured during rest, alertness and activity. Furthermore, the ABP response to being petted by familiar and unfamiliar persons was assessed. Linear mixed modelling revealed that the mean blood pressure (MBP) in resting cats (114.6mmHg) was lower (P<0.001) than in alert cats (122.7mmHg), which was lower (P<0.001) than that of active cats (136.8mmHg). The MBP during petting by a familiar person (144.7mmHg) tended to be higher (P=0.065) than that during petting by an unfamiliar person (139.4mmHg). The MBP of active cats was lower (P=0.003) than MBP of cats petted by a familiar person, but not different from MBP of cats petted by an unfamiliar person. The MBP returned to resting values between 16 and 20min after the familiar person had left, whereas resting values were reached between 11 and 15min after the unfamiliar person had left. The complications of the described method were limited considering the potential risks of continuous direct ABP measurement. In conclusion, the described technique enables accurate measurement of feline ABP, which is influenced by the cat's activity level and the familiarity of persons.

Entities:  

Mesh:

Year:  2008        PMID: 18255107     DOI: 10.1016/j.rvsc.2007.12.008

Source DB:  PubMed          Journal:  Res Vet Sci        ISSN: 0034-5288            Impact factor:   2.534


  4 in total

Review 1.  Non-invasive blood pressure measurement in animals: Part 1 - Techniques for measurement and validation of non-invasive devices.

Authors:  Alicia Skelding; Alexander Valverde
Journal:  Can Vet J       Date:  2020-04       Impact factor: 1.008

2.  Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats.

Authors:  Petra Cerna; Panos E Archontakis; Hester Ok Cheuk; Danièlle A Gunn-Moore
Journal:  J Feline Med Surg       Date:  2020-06-25       Impact factor: 2.015

3.  Influence of clinical setting and cat characteristics on indirectly measured blood pressure and pulse rate in healthy Birman, Norwegian Forest, and Domestic Shorthair cats.

Authors:  Sofia Hanås; Bodil S Holst; Ingrid Ljungvall; Anna Tidholm; Ulf Olsson; Jens Häggström; Katja Höglund
Journal:  J Vet Intern Med       Date:  2021-03-06       Impact factor: 3.333

4.  ACVIM consensus statement: Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats.

Authors:  Mark J Acierno; Scott Brown; Amanda E Coleman; Rosanne E Jepson; Mark Papich; Rebecca L Stepien; Harriet M Syme
Journal:  J Vet Intern Med       Date:  2018-10-24       Impact factor: 3.333

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.