Literature DB >> 18251640

The influence of non-matching implant and abutment diameters on radiographic crestal bone levels in dogs.

Ronald E Jung1, Archie A Jones, Frank L Higginbottom, Thomas G Wilson, John Schoolfield, Daniel Buser, Christoph H F Hämmerle, David L Cochran.   

Abstract

BACKGROUND: It has been shown that different implant designs and different vertical implant positions have an influence on crestal bone levels. The aim of the present study was to evaluate radiographic crestal bone changes around experimental dental implants with non-matching implant-abutment diameters placed submucosally or transmucosally at three different levels relative to the alveolar crest.
METHODS: Sixty two-piece dental implants with non-matching implant-abutment diameters were placed in edentulous spaces bilaterally in five foxhounds. The implants were placed submucosally or transmucosally in the left or the right side of the mandible. Within each side, six implants were randomly placed at three distinct levels relative to the alveolar crest. After 12 weeks, 60 crowns were cemented. Radiographs were obtained from all implant sites following implant placement, after crown insertion, and monthly for 6 months after loading.
RESULTS: Radiographic analysis revealed very little bone loss and a slight increase in bone level for implants placed at the level of the crest or 1 mm above. The greatest bone loss occurred at implants placed 1 mm below the bone crest. No clinically significant differences regarding marginal bone loss and the level of the bone-to-implant contact were detected between implants with a submucosal or a transmucosal healing.
CONCLUSIONS: Implants with non-matching implant-abutment diameters demonstrated some bone loss; however, it was a small amount. There was no clinically significant difference between submucosal and transmucosal approaches.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18251640     DOI: 10.1902/jop.2008.070132

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  15 in total

1.  Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study.

Authors:  Seok-Gyu Kim; Pil-Young Yun; Hyun-Sik Park; June-Sung Shim; Jung-Won Hwang; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

Review 2.  Influence of subcrestal implant placement compared with equicrestal position on the peri-implant hard and soft tissues around platform-switched implants: a systematic review and meta-analysis.

Authors:  Cristina Valles; Xavier Rodríguez-Ciurana; Marco Clementini; Mariana Baglivo; Blanca Paniagua; Jose Nart
Journal:  Clin Oral Investig       Date:  2018-01-08       Impact factor: 3.573

3.  A non-interventional multicenter study to document the implants success and survival rates in daily dental practices of the CONELOG screw-line implant.

Authors:  Claudio Cacaci; Karl-Ludwig Ackermann; Thomas Barth; Steffen Kistler; Michael Stiller; Markus Schlee
Journal:  Clin Oral Investig       Date:  2018-10-15       Impact factor: 3.573

4.  Marginal bone loss around crestal or subcrestal dental implants: prospective clinical study.

Authors:  Naser Sargolzaie; Hosein Hoseini Zarch; Hamidreza Arab; Tahereh Koohestani; Mahdiye Fasihi Ramandi
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2022-06-30

5.  Retrospective Clinical Study of Marginal Bone Level Changes with Two Different Screw-Implant Types: Comparison Between Tissue Level (TE) and Bone Level (BL) Implant.

Authors:  Vinay V Kumar; Keyvan Sagheb; Peer W Kämmerer; Bilal Al-Nawas; Wilfried Wagner
Journal:  J Maxillofac Oral Surg       Date:  2013-06-11

Review 6.  Soft tissue augmentation procedures at second-stage surgery: a systematic review.

Authors:  Renzo G Bassetti; Alexandra Stähli; Mario A Bassetti; Anton Sculean
Journal:  Clin Oral Investig       Date:  2016-04-04       Impact factor: 3.573

7.  Platform switching on wide-diameter external hex implants: a finite element analysis.

Authors:  Stefano Sivolella; Riccardo Guazzo; Eriberto Bressan; Mario Berengo; Edoardo Stellini
Journal:  J Clin Exp Dent       Date:  2013-04-01

Review 8.  Marginal bone loss in relation to platform switching implant insertion depth: An update.

Authors:  Rocío Alonso-González; Amparo Aloy-Prósper; David Peñarrocha-Oltra; M A Peñarrocha-Diago; M Peñarrocha-Diago
Journal:  J Clin Exp Dent       Date:  2012-07-01

Review 9.  Impact of implant-abutment connection and positioning of the machined collar/microgap on crestal bone level changes: a systematic review.

Authors:  Frank Schwarz; Andrea Hegewald; Jürgen Becker
Journal:  Clin Oral Implants Res       Date:  2013-06-18       Impact factor: 5.977

Review 10.  Impact of platform switching on marginal peri-implant bone-level changes. A systematic review and meta-analysis.

Authors:  Frank Peter Strietzel; Konrad Neumann; Moritz Hertel
Journal:  Clin Oral Implants Res       Date:  2014-01-20       Impact factor: 5.977

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.