Literature DB >> 18250756

Ultrasensitive laser measurements without tears.

P C Hobbs1.   

Abstract

Several easily implemented devices for doing ultrasensitive optical measurements with noisy lasers are presented. They are all-electronic noise cancellation circuits that largely eliminate excess laser intensity noise as a source of measurement error and are widely applicable. Shot-noise-limited optical measurements can now easily be made at baseband with noisy lasers. These circuits are especially useful in situations where strong intermodulation effects exist, such as current-tuned diode laser spectroscopy. These inexpensive devices (parts cost approximately $10) can be optimized for particular applications such as wideband or differential measurements. Although they cannot eliminate phase noise effects, they can reduce amplitude noise by 55-70 dB or more, even in unattended operation, and usually achieve the shot-noise limit. With 1-Hz signal-to-noise ratios of 150-160 dB, they allow performance equal or superior to a complex heterodyne system in many cases, while using much simpler dual-beam or homodyne approaches. Although these devices are related to earlier differential and ratiometric techniques, their noise cancellation performance is much better. They work well at modulation frequencies from dc to several megahertz and should be extensible to approximately 100 MHz. The circuits work by subtracting photocurrents directly, with feedback applied outside the signal path to continuously adjust the subtraction for perfect balance; thus the excess noise and spurious modulation ideally cancel at all frequencies, leaving only the shot noise. The noise cancellation bandwidth is independent of the feedback bandwidth; it depends only on the speeds of the photodiodes and of the bipolar junction transistors used. Two noise-canceled outputs are available; one is a high-pass filtered voltage proportional to the signal photocurrent and the other is a low-pass filtered voltage related to the log ratio of the signal and comparison photocurrents. For reasonable current densities, the noise floors of the outputs depend only on the shot noise of the signal beam. Four variations on the basic circuit are presented: low noise floor, high cancellation, differential high power, and ratio-only. Emphasis is placed on the detailed operation and design considerations, especially performance extension by compensation of the nonideal character of system components. Experience has shown that some applications advice is required by most users, so that is provided as well.

Year:  1997        PMID: 18250756     DOI: 10.1364/ao.36.000903

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  8 in total

1.  Frequency-domain birefringence measurement of biological binding to magnetic nanoparticles.

Authors:  Benjamin Y Ku; Mei-Lin Chan; Zhiya Ma; David A Horsley
Journal:  J Magn Magn Mater       Date:  2008       Impact factor: 2.993

2.  Pulsed ultrasound-modulated optical tomography using spectral-hole burning as a narrowband spectral filter.

Authors:  Youzhi Li; Huiliang Zhang; Chulhong Kim; Kelvin H Wagner; Philip Hemmer; Lihong V Wang
Journal:  Appl Phys Lett       Date:  2008-07-11       Impact factor: 3.791

3.  Field-resolved infrared spectroscopy of biological systems.

Authors:  Ioachim Pupeza; Marinus Huber; Michael Trubetskov; Wolfgang Schweinberger; Syed A Hussain; Christina Hofer; Kilian Fritsch; Markus Poetzlberger; Lenard Vamos; Ernst Fill; Tatiana Amotchkina; Kosmas V Kepesidis; Alexander Apolonski; Nicholas Karpowicz; Vladimir Pervak; Oleg Pronin; Frank Fleischmann; Abdallah Azzeer; Mihaela Žigman; Ferenc Krausz
Journal:  Nature       Date:  2020-01-01       Impact factor: 49.962

4.  Detection of ultrasound-modulated diffuse photons using spectral-hole burning.

Authors:  Youzhi Li; Philip Hemmer; Chulhong Kim; Huiliang Zhang; Lihong V Wang
Journal:  Opt Express       Date:  2008-09-15       Impact factor: 3.894

5.  Computational imaging with a balanced detector.

Authors:  F Soldevila; P Clemente; E Tajahuerce; N Uribe-Patarroyo; P Andrés; J Lancis
Journal:  Sci Rep       Date:  2016-06-29       Impact factor: 4.379

6.  Polarimetric Balanced Detection: Background-Free Mid-IR Evanescent Field Laser Spectroscopy for Low-Noise, Long-term Stable Chemical Sensing.

Authors:  Stephan Freitag; Matthias Baer; Laura Buntzoll; Georg Ramer; Andreas Schwaighofer; Bernhard Schmauss; Bernhard Lendl
Journal:  ACS Sens       Date:  2020-12-29       Impact factor: 7.711

7.  Unbiased Plasmonic-Assisted Integrated Graphene Photodetectors.

Authors:  Ioannis Vangelidis; Dimitris V Bellas; Stephan Suckow; George Dabos; Sebastián Castilla; Frank H L Koppens; Andrea C Ferrari; Nikos Pleros; Elefterios Lidorikis
Journal:  ACS Photonics       Date:  2022-06-02       Impact factor: 7.077

8.  Intensity-Stabilized Fast-Scanned Direct Absorption Spectroscopy Instrumentation Based on a Distributed Feedback Laser with Detection Sensitivity down to 4 × 10-6.

Authors:  Gang Zhao; Wei Tan; Mengyuan Jia; Jiajuan Hou; Weiguang Ma; Lei Dong; Lei Zhang; Xiaoxia Feng; Xuechun Wu; Wangbao Yin; Liantuan Xiao; Ove Axner; Suotang Jia
Journal:  Sensors (Basel)       Date:  2016-09-21       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.