Literature DB >> 18247772

Within- and across-channel gap detection in cochlear implant listeners.

John H Grose1, Emily Buss.   

Abstract

This study examined within- and across-electrode-channel processing of temporal gaps in successful users of MED-EL COMBI 40+ cochlear implants. The first experiment tested across-ear gap duration discrimination (GDD) in four listeners with bilateral implants. The results demonstrated that across-ear GDD thresholds are elevated relative to monaural, within-electrode-channel thresholds; the size of the threshold shift was approximately the same as for monaural, across-electrode-channel configurations. Experiment 1 also demonstrated a decline in GDD performance for channel-asymmetric markers. The second experiment tested the effect of envelope fluctuation on gap detection (GD) for monaural markers carried on a single electrode channel. Results from five cochlear implant listeners indicated that envelopes associated with 50-Hz wide bands of noise resulted in poorer GD thresholds than envelopes associated with 300-Hz wide bands of noise. In both cases GD thresholds improved when envelope fluctuations were compressed by an exponent of 0.2. The results of both experiments parallel those found for acoustic hearing, therefore suggesting that temporal processing of gaps is largely limited by factors central to the cochlea.

Entities:  

Mesh:

Year:  2007        PMID: 18247772     DOI: 10.1121/1.2793608

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  6 in total

1.  Auditory temporal acuity probed with cochlear implant stimulation and cortical recording.

Authors:  Alana E Kirby; John C Middlebrooks
Journal:  J Neurophysiol       Date:  2009-11-18       Impact factor: 2.714

2.  Age-Related Changes in Temporal Resolution Revisited: Electrophysiological and Behavioral Findings From Cochlear Implant Users.

Authors:  Bruna S S Mussoi; Carolyn J Brown
Journal:  Ear Hear       Date:  2019 Nov/Dec       Impact factor: 3.570

3.  Unanesthetized auditory cortex exhibits multiple codes for gaps in cochlear implant pulse trains.

Authors:  Alana E Kirby; John C Middlebrooks
Journal:  J Assoc Res Otolaryngol       Date:  2011-10-04

4.  The Gap Detection Test: Can It Be Used to Diagnose Tinnitus?

Authors:  Kris Boyen; Deniz Başkent; Pim van Dijk
Journal:  Ear Hear       Date:  2015 Jul-Aug       Impact factor: 3.570

5.  Comodulation masking release in electric hearing.

Authors:  Robert H Pierzycki; Bernhard U Seeber
Journal:  J Assoc Res Otolaryngol       Date:  2014-01-11

6.  Within- and across-frequency temporal processing and speech perception in cochlear implant users.

Authors:  Chelsea M Blankenship; Jareen Meinzen-Derr; Fawen Zhang
Journal:  PLoS One       Date:  2022-10-13       Impact factor: 3.752

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.