Literature DB >> 18244306

Target detectability in acoustic elastography.

M Bilgen1.   

Abstract

The clinically relevant task of visually detecting low contrast targets in noisy strain images estimated from ultrasonic signals is studied. Detectability is measured quantitatively using contrast-to-noise ratio (CNR) analysis. Contrast in strain images is generated by a complex interaction among the soft tissue elasticity shear modulus distribution, target shape and location in the stress field, and external boundary conditions. Although a large strain variation is preferred for enhancing the contrast, this also increases the signal-dependent noise in strain estimates in a nonlinear fashion. Therefore, understanding the tradeoffs between contrast and noise is necessary for improving the diagnostic performance of strain imaging. In this paper, targets with slab, cylindrical, and spherical geometries are studied. Strains in the target and background and the precision of their estimates are described in terms of the corresponding shear modulus values for each geometry. These results are then incorporated into the CNR expression to investigate the changes in target detectability with the variation of shear modulus in the target and the ultrasonic signal parameters (echo signal-to-noise ratio and inverse fractional bandwidth) as well as the signal processing variables (time-bandwidth product and fractional window overlap).

Year:  1999        PMID: 18244306     DOI: 10.1109/58.796118

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  8 in total

1.  Volumetric elasticity imaging with a 2-D CMUT array.

Authors:  Ted G Fisher; Timothy J Hall; Satchi Panda; Michael S Richards; Paul E Barbone; Jingfeng Jiang; Jeff Resnick; Steve Barnes
Journal:  Ultrasound Med Biol       Date:  2010-06       Impact factor: 2.998

2.  A novel performance descriptor for ultrasonic strain imaging: a preliminary study.

Authors:  Jingfeng Jiang; Timothy J Hall; Amy M Sommer
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

3.  Shear modulus reconstruction by ultrasonically measured strain ratio.

Authors:  Chikayoshi Sumi; Hidenori Matsuzawa
Journal:  J Med Ultrason (2001)       Date:  2007-12-14       Impact factor: 1.314

4.  Improved hardware for higher spatial resolution strain-encoded (SENC) breast MRI for strain measurements.

Authors:  Ahmed A Harouni; Jakir Hossain; Michael A Jacobs; Nael F Osman
Journal:  Acad Radiol       Date:  2011-03-25       Impact factor: 3.173

5.  Ultrasound-based relative elastic modulus imaging for visualizing thermal ablation zones in a porcine model.

Authors:  Jingfeng Jiang; Chris Brace; Anita Andreano; Ryan J DeWall; Nick Rubert; Ted G Fisher; Tomy Varghese; Fred Lee; Timothy J Hall
Journal:  Phys Med Biol       Date:  2010-03-30       Impact factor: 3.609

6.  Automatic generation of boundary conditions using demons nonrigid image registration for use in 3-D modality-independent elastography.

Authors:  Thomas S Pheiffer; Jao J Ou; Rowena E Ong; Michael I Miga
Journal:  IEEE Trans Biomed Eng       Date:  2011-06-16       Impact factor: 4.538

7.  Quasi-Static Ultrasound Elastography.

Authors:  Tomy Varghese
Journal:  Ultrasound Clin       Date:  2009-07

8.  Sonoelastic response of median nerve to rehabilitation in carpal tunnel syndrome.

Authors:  Yasemin Durum Polat; Elif Aydın; Fikriye Sinem Ince; Mehmet Bilgen
Journal:  J Ultrason       Date:  2020-06-15
  8 in total