Literature DB >> 18242455

Outcomes of coaxial microincision cataract surgery versus conventional coaxial cataract surgery.

André Alexandre Dosso1, Laura Cottet, Nathalie Dang Burgener, Silvio Di Nardo.   

Abstract

PURPOSE: To compare the outcomes of coaxial microincision cataract surgery (MICS) with those of conventional coaxial cataract surgery.
SETTING: University Eye Clinic, Geneva, Switzerland.
METHODS: In a prospective study, 50 eyes of 50 patients with nuclear or corticonuclear cataract (grades 2 to 4 on the Lens Opacities Classification System III) were randomly selected to have cataract extraction through a temporal clear corneal incision using 1 of 2 techniques: coaxial MICS (25 eyes) or conventional coaxial cataract surgery (25 eyes). Coaxial MICS was performed through a 1.6 mm incision and conventional coaxial cataract surgery, through a 2.8 mm incision. In all cases, a flexible hydrophobic acrylic intraocular lens (Lentis L-303, WaveLight GmbH) was implanted. Intraoperative parameters were ultrasound time, surgical time, and total volume of balanced salt solution used. The best corrected visual acuity, corneal thickness, and endothelial cell count were evaluated preoperatively and postoperatively.
RESULTS: There were no relevant clinical differences between groups or perioperative complications in either group. The only statistically significant differences between the 2 groups were ultrasound time (P = .0002) and surgical time (P = .005).
CONCLUSIONS: Coaxial microincision cataract surgery was a safe and effective technique. Although ultrasound and surgical time were significantly higher with coaxial MICS than with conventional coaxial cataract surgery, the postoperative results in the 2 techniques were comparable.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18242455     DOI: 10.1016/j.jcrs.2007.09.037

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Comparative analysis of coaxial phacoemulsification with 2.2- and 2.8-mm clear corneal incisions.

Authors:  Harinder Singh Sethi; Komal Saluja; Mayuresh P Naik
Journal:  Int Ophthalmol       Date:  2017-01-31       Impact factor: 2.031

2.  Bimanual microincisional cataract surgery technique and clinical outcome.

Authors:  Abdulrahman Al-Muammar
Journal:  Saudi J Ophthalmol       Date:  2009-08-05

3.  [Intraocular lenses for microincisional cataract surgery].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

Review 4.  Different-sized incisions for phacoemulsification in age-related cataract.

Authors:  Chongfei Jin; Xinyi Chen; Andrew Law; Yunhee Kang; Xue Wang; Wen Xu; Ke Yao
Journal:  Cochrane Database Syst Rev       Date:  2017-09-20

5.  Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification.

Authors:  László Jr Módis; Eszter Szalai; Zsuzsa Flaskó; Gábor Németh
Journal:  Rom J Ophthalmol       Date:  2016 Apr-Jun

6.  Risk factors for endothelial cell loss after phacoemulsification: comparison in different anterior chamber depth groups.

Authors:  Yang Kyeung Cho; Hwa Seok Chang; Man Soo Kim
Journal:  Korean J Ophthalmol       Date:  2010-02-05

7.  Immediate changes in intraocular pressure after clear corneal micro-incision versus small-incision cataract surgery.

Authors:  Ken Hayashi; Motoaki Yoshida; Koichi Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2014-06-28       Impact factor: 2.447

8.  Surgical and Functional Results of Hybrid 25-27-Gauge Vitrectomy Combined with Coaxial 2.2 mm Small Incision Cataract Surgery.

Authors:  Fabian Höhn; Florian Kretz; Mitrofanis Pavlidis
Journal:  J Ophthalmol       Date:  2016-02-04       Impact factor: 1.909

Review 9.  Comparison of efficacy between coaxial microincision and standard-incision phacoemulsification in patients with age-related cataracts: a meta-analysis.

Authors:  Lijun Wang; Xiao Xiao; Lin Zhao; Yi Zhang; Jianming Wang; Aiyi Zhou; Jianchao Wang; Qian Wu
Journal:  BMC Ophthalmol       Date:  2017-12-29       Impact factor: 2.209

10.  Coaxial Microincision Cataract Surgery versus Standard Coaxial Small-Incision Cataract Surgery: A Meta-Analysis of Randomized Controlled Trials.

Authors:  Xingchao Shentu; Xin Zhang; Xiajing Tang; Xiaoning Yu
Journal:  PLoS One       Date:  2016-01-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.