Literature DB >> 18238474

Extending the frequency range of the National Physical Laboratory primary standard laser interferometer for hydrophone calibrations to 80 MHz.

T J Esward1, S P Robinson.   

Abstract

A method for the primary calibration of hydrophones in the frequency range up to 60 MHz is described. The current National Physical Laboratory (NPL) primary standard method of calibrating ultrasonic hydrophones from 500 kHz to 20 MHz is based on optical interferometry. The acoustic field produced by a transducer is detected by an acoustically transparent but optically reflecting pellicle. Optical interferometric measurements of pellicle displacement at discrete frequencies in tone-burst fields are converted to acoustic pressure, and the hydrophone for calibration is substituted at the same point, allowing sensitivity in volts per pascal to be obtained directly. For calibrations up to 60 MHz, the interferometer is capable of measuring the displacement of the pellicle as a function of frequency in a harmonically rich nonlinear field up to and including the 12th harmonic of the shocked field generated by a 5 MHz focusing transducer, allowing hydrophones to be calibrated by substitution in the same field. Sources of uncertainty in the new method have been investigated. Best combined random and systematic uncertainties at the 95% confidence level for the new method are 7% at 20 MHz, 11% at 40 MHz, and 16% at 60 MHz.

Year:  1999        PMID: 18238474     DOI: 10.1109/58.764860

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  4 in total

1.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part II: Experimental Validation of Spatial Averaging Model.

Authors:  Keith A Wear; Yunbo Liu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

2.  Nonlinear Acoustics in Ultrasound Metrology and other Selected Applications.

Authors:  Peter A Lewin
Journal:  Phys Procedia       Date:  2010-01-01

3.  Correction for Spatial Averaging Artifacts in Hydrophone Measurements of High-Intensity Therapeutic Ultrasound: An Inverse Filter Approach.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-24       Impact factor: 2.725

4.  Calibration Methods of Acoustic Emission Sensors.

Authors:  Kanji Ono
Journal:  Materials (Basel)       Date:  2016-06-24       Impact factor: 3.623

  4 in total