Literature DB >> 18230462

The circular harmonic transform for SPECT reconstruction and boundary conditions on the Fourier transform of the sinogram.

W G Hawkins1, P K Leichner, N C Yang.   

Abstract

The circular harmonic transform (CHT) solution of the exponential Randon transform (ERT) is applied to single-photon emission computed tomography (SPECT) for uniform attenuation within a convex boundary. An important special case also considered is the linear (unattenuated) Radon transform (LRT). The solution is on the form of an orthogonal function expansion matched to projections that are in parallel-ray geometry. This property allows for efficient and accurate processing of the projections with fast Fourier transform (FFT) without interpolation or beam matching. The algorithm is optimized by the use of boundary conditions on the 2-D Fourier transform of the sinogram. These boundary conditions imply that the signal energy of the sinogram is concentrated in well-defined sectors in transform space. The angle defining the sectors depends in a direct way on the radius of the field view. These results are also obtained for fan-beam geometry and the linear Radon transform (the Fourier-Chebyshev transform of the sinogram) to demonstrate that the boundary conditions are a more general property of the Radon transform and a not a property unique to rectangular coordinates.

Year:  1988        PMID: 18230462     DOI: 10.1109/42.3940

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  6 in total

Review 1.  Quantitative analysis in single photon emission tomography (SPET).

Authors:  K A Blokland; H H Reiber; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1992

2.  A Fourier reconstruction algorithm with constant attenuation compensation using 180 degrees acquisition data for SPECT.

Authors:  Qiulin Tang; Gengsheng L Zeng; Grant T Gullberg
Journal:  Phys Med Biol       Date:  2007-10-01       Impact factor: 3.609

Review 3.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms.

Authors:  M A King; B M Tsui; T S Pan; S J Glick; E J Soares
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

4.  Noise-Weighted FBP Algorithm for Uniformly Attenuated SPECT Projections.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2016-06-23       Impact factor: 1.679

5.  Motion compensation for cone-beam CT using Fourier consistency conditions.

Authors:  M Berger; Y Xia; W Aichinger; K Mentl; M Unberath; A Aichert; C Riess; J Hornegger; R Fahrig; A Maier
Journal:  Phys Med Biol       Date:  2017-08-21       Impact factor: 3.609

6.  Simplifying volumes-of-interest (VOIs) definition in quantitative SPECT: Beyond manual definition of 3D whole-organ VOIs.

Authors:  Esther M Vicente; Martin A Lodge; Steven P Rowe; Richard L Wahl; Eric C Frey
Journal:  Med Phys       Date:  2017-03-28       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.