Numerical field evaluation of healthcare workers when bending towards high-field MRI magnets.

H Wang1, A Trakic, F Liu, S Crozier.   

Abstract

In MRI, healthcare workers may be exposed to strong static and dynamic magnetic fields outside of the imager. Body motion through the strong, non-uniform static magnetic field generated by the main superconducting magnet and exposure to gradient-pulsed magnetic fields can result in the induction of electric fields and current densities in the tissue. The interaction of these fields and occupational workers has attracted an increasing awareness. To protect occupational workers from overexposure, the member states of the European Union are required to incorporate the Physical Agents Directive (PAD) 2004/40/EC into their legislation. This study presents numerical evaluations of electric fields and current densities in anatomically equivalent male and female human models (healthcare workers) as they lean towards the bores of three superconducting magnet models (1.5, 4, and 7 T) and x-, y-, and z- gradient coils. The combined effect of the 1.5 T superconducting magnet and the three gradient coils on the body models is compared with the contributions of the magnet and gradient coils in separation. The simulation results indicate that it is possible to induce field quantities of physiological significance, especially when the MRI operator is bending close towards the main magnet and all three gradient coils are switched simultaneously. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18228572     DOI: 10.1002/mrm.21441

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

Review 1.  Occupational exposure in MRI.

Authors:  D W McRobbie
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

Review 2.  The revised electromagnetic fields directive and worker exposure in environments with high magnetic flux densities.

Authors:  Rianne Stam
Journal:  Ann Occup Hyg       Date:  2014-02-20

Review 3.  Occupational exposure to electromagnetic fields in magnetic resonance environment: basic aspects and review of exposure assessment approaches.

Authors:  Valentina Hartwig; Stefania Romeo; Olga Zeni
Journal:  Med Biol Eng Comput       Date:  2018-01-18       Impact factor: 2.602

Review 4.  Occupational exposure to electromagnetic fields in magnetic resonance environment: an update on regulation, exposure assessment techniques, health risk evaluation, and surveillance.

Authors:  Valentina Hartwig; Giorgio Virgili; F Ederica Mattei; Cristiano Biagini; Stefania Romeo; Olga Zeni; Maria Rosaria Scarfì; Rita Massa; Francesco Campanella; Luigi Landini; Fabriziomaria Gobba; Alberto Modenese; Giulio Giovannetti
Journal:  Med Biol Eng Comput       Date:  2021-09-29       Impact factor: 2.602

5.  Acute vertigo in an anesthesia provider during exposure to a 3T MRI scanner.

Authors:  Andrew Gorlin; Joseph M Hoxworth; William Pavlicek; Christopher A Thunberg; David Seamans
Journal:  Med Devices (Auckl)       Date:  2015-03-10

6.  Exposure Assessment and Biomonitoring of Workers in Magnetic Resonance Environment: An Exploratory Study.

Authors:  Anna Sannino; Stefania Romeo; Maria Rosaria Scarfì; Rita Massa; Raffaele d'Angelo; Antonella Petrillo; Vincenzo Cerciello; Roberta Fusco; Olga Zeni
Journal:  Front Public Health       Date:  2017-12-18

Review 7.  Occupational exposure to electromagnetic fields from medical sources.

Authors:  Rianne Stam; Sachiko Yamaguchi-Sekino
Journal:  Ind Health       Date:  2017-11-03       Impact factor: 2.179