Literature DB >> 18227352

Early automatic remote detection of combined lead insulation defect and ICD damage.

Petr Neuzil1, Milos Taborsky, Frantisek Holy, Karsten Wallbrueck.   

Abstract

Lead and implantable cardioverter defibrillator (ICD) device failure is a severe problem in ICD therapy and may occur without preceding signs of deterioration. Insulation lead failure and subsequent ICD defect 7 months after ICD implantation for secondary prevention of sudden cardiac death (SCD) in a 70-year-old male was automatically detected with the Home Monitoring system. Immediate lead and device replacement was performed. This case illustrates the benefit of permanent automatic remote monitoring of implanted active devices.

Entities:  

Mesh:

Year:  2008        PMID: 18227352     DOI: 10.1093/europace/eun009

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  14 in total

1.  ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs).

Authors:  Sergio Dubner; Angelo Auricchio; Jonathan S Steinberg; Panos Vardas; Peter Stone; Josep Brugada; Ryszard Piotrowicz; David L Hayes; Paulus Kirchhof; Günter Breithardt; Wojciech Zareba; Claudio Schuger; Mehmet K Aktas; Michal Chudzik; Suneet Mittal; Niraj Varma
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-01       Impact factor: 1.468

Review 2.  Strategic choices to reduce implantable cardioverter-defibrillator-related morbidity.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2010-04-20       Impact factor: 32.419

3.  Workload, time and costs of the informal cares in patients with tele-monitoring of pacemakers: the PONIENTE study.

Authors:  Antonio López-Villegas; Daniel Catalán-Matamoros; Emilio Robles-Musso; Salvador Peiró
Journal:  Clin Res Cardiol       Date:  2015-09-30       Impact factor: 5.460

Review 4.  Considerations for cardiac device lead extraction.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2016-01-29       Impact factor: 32.419

5.  Subject of the year: remote monitoring.

Authors:  Fred Kusumoto; Nora Goldschlager
Journal:  J Interv Card Electrophysiol       Date:  2009-04-24       Impact factor: 1.900

6.  Impact of in-clinic follow-up visits in patients with implantable cardioverter defibrillators: demographic and socioeconomic analysis of the TARIFF study population.

Authors:  Renato P Ricci; Alfredo Vicentini; Antonio D'Onofrio; Antonio Sagone; Antonio Vincenti; Luigi Padeletti; Loredana Morichelli; Antonio Fusco; Filippo Vecchione; Francesco Lo Presti; Alessandra Denaro; Annalisa Pollastrelli; Massimo Santini
Journal:  J Interv Card Electrophysiol       Date:  2013-09-21       Impact factor: 1.900

Review 7.  Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems.

Authors:  Werner Jung; Andreas Rillig; Ralf Birkemeyer; Tomislav Miljak; Udo Meyerfeldt
Journal:  J Interv Card Electrophysiol       Date:  2008-09-27       Impact factor: 1.900

8.  [Telemedicine in pacemaker therapy and follow-up].

Authors:  A Schuchert
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-12

Review 9.  Remote monitoring of patients with implanted cardiac devices.

Authors:  Fred Kusumoto; Nora Goldschlager
Journal:  Clin Cardiol       Date:  2010-01       Impact factor: 2.882

10.  Remote Monitoring for Follow-up of Patients with Cardiac Implantable Electronic Devices.

Authors:  Renato Pietro Ricci; Loredana Morichelli; Niraj Varma
Journal:  Arrhythm Electrophysiol Rev       Date:  2014-08-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.