Literature DB >> 18226544

Simultaneous fragmentation of multiple ions using IMS drift time dependent collision energies.

Erin Shammel Baker1, Keqi Tang, William F Danielson, David C Prior, Richard D Smith.   

Abstract

Ion mobility spectrometry coupled with mass spectrometry (IMS-MS) was utilized to evaluate an ion collision energy ramping technique that simultaneously fragments a variety of species. To evaluate this technique, the fragmentation patterns of a mixture of ions ranging in mass, charge state, and drift time were analyzed to determine their optimal fragmentation conditions. The precursor ions were pulsed into the IMS-MS instrument and separated in the IMS drift cell based on mobility differences. Two differentially pumped short quadrupoles were used to focus the ions exiting the drift cell, and fragmentation was induced by collision induced dissociation (CID) between the conductance limiting orifice behind the second short quadrupole and before the first octopole in the mass spectrometer. To explore the fragmentation spectrum of each precursor ion, the bias voltages for the short quadrupoles and conductance limiting orifices were increased from 0 to 50 V above nonfragmentation voltage settings. An approximately linear correlation was observed between the optimal fragmentation voltage for each ion and its specific drift time, so a linear voltage gradient was employed to supply less collision energy to high mobility ions (e.g., small conformations or higher charge state ions) and more to low mobility ions. Fragmentation efficiencies were found to be similar for different ions when the fragmentation voltage was linearly ramped with drift time, but varied drastically when only a single voltage was used.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18226544      PMCID: PMC2517259          DOI: 10.1016/j.jasms.2007.11.018

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  30 in total

1.  Tandem mass spectrometry: dissociation of ions by collisional activation

Authors: 
Journal:  J Mass Spectrom       Date:  2000-09       Impact factor: 1.982

Review 2.  Peptides and proteins: overview and strategy.

Authors:  K Biemann
Journal:  Methods Enzymol       Date:  1990       Impact factor: 1.600

3.  An IMS-IMS analogue of MS-MS.

Authors:  Stormy L Koeniger; Samuel I Merenbloom; Stephen J Valentine; Martin F Jarrold; Harold R Udseth; Richard D Smith; David E Clemmer
Journal:  Anal Chem       Date:  2006-06-15       Impact factor: 6.986

4.  Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry.

Authors:  Ryan T Kelly; Jason S Page; Quanzhou Luo; Ronald J Moore; Daniel J Orton; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

5.  Ion mobility spectrometry-mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures.

Authors:  Erin Shammel Baker; Brian H Clowers; Fumin Li; Keqi Tang; Aleksey V Tolmachev; David C Prior; Mikhail E Belov; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2007-04-06       Impact factor: 3.109

Review 6.  Mass spectrometry.

Authors:  A L Burlingame; R K Boyd; S J Gaskell
Journal:  Anal Chem       Date:  1996-06-15       Impact factor: 6.986

7.  Electrospray ionization and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry of permethylated oligosaccharides.

Authors:  T Solouki; B B Reinhold; C E Costello; M O'Malley; S Guan; A G Marshall
Journal:  Anal Chem       Date:  1998-03-01       Impact factor: 6.986

8.  Subfemtomole MS and MS/MS peptide sequence analysis using nano-HPLC micro-ESI fourier transform ion cyclotron resonance mass spectrometry.

Authors:  S E Martin; J Shabanowitz; D F Hunt; J A Marto
Journal:  Anal Chem       Date:  2000-09-15       Impact factor: 6.986

9.  Application of peptide LC retention time information in a discriminant function for peptide identification by tandem mass spectrometry.

Authors:  Eric F Strittmatter; Lars J Kangas; Konstantinos Petritis; Heather M Mottaz; Gordon A Anderson; Yufeng Shen; Jon M Jacobs; David G Camp; Richard D Smith
Journal:  J Proteome Res       Date:  2004 Jul-Aug       Impact factor: 4.466

10.  Gas-phase ion chromatography: transition metal state selection and carbon cluster formation.

Authors:  M T Bowers; P R Kemper; G von Helden; P A van Koppen
Journal:  Science       Date:  1993-06-04       Impact factor: 47.728

View more
  19 in total

1.  An ion mobility/ion trap/photodissociation instrument for characterization of ion structure.

Authors:  Steven M Zucker; Sunyoung Lee; Nathaniel Webber; Stephen J Valentine; James P Reilly; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2011-07-09       Impact factor: 3.109

2.  Overtone mobility spectrometry: part 4. OMS-OMS analyses of complex mixtures.

Authors:  Ruwan T Kurulugama; Fabiane M Nachtigall; Stephen J Valentine; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2011-08-09       Impact factor: 3.109

3.  A novel approach to collision-induced dissociation (CID) for ion mobility-mass spectrometry experiments.

Authors:  Christopher Becker; Francisco A Fernandez-Lima; Kent J Gillig; William K Russell; Stephanie M Cologna; David H Russell
Journal:  J Am Soc Mass Spectrom       Date:  2008-12-09       Impact factor: 3.109

4.  Applying a dynamic method to the measurement of ion mobility.

Authors:  Gökhan Baykut; Oliver von Halem; Oliver Raether
Journal:  J Am Soc Mass Spectrom       Date:  2009-07-30       Impact factor: 3.109

5.  Enhancing bottom-up and top-down proteomic measurements with ion mobility separations.

Authors:  Erin Shammel Baker; Kristin E Burnum-Johnson; Yehia M Ibrahim; Daniel J Orton; Matthew E Monroe; Ryan T Kelly; Ronald J Moore; Xing Zhang; Roger Théberge; Catherine E Costello; Richard D Smith
Journal:  Proteomics       Date:  2015-07-03       Impact factor: 3.984

6.  Characterization of an Ion Mobility-Multiplexed Collision Induced Dissociation-Tandem Time-of-Flight Mass Spectrometry Approach.

Authors:  Yehia M Ibrahim; David C Prior; Erin S Baker; Richard D Smith; Mikhail E Belov
Journal:  Int J Mass Spectrom       Date:  2010-06-01       Impact factor: 1.986

7.  Separation of protein conformers by differential ion mobility in hydrogen-rich gases.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  Anal Chem       Date:  2013-06-25       Impact factor: 6.986

8.  Artificial neural networks for the prediction of peptide drift time in ion mobility mass spectrometry.

Authors:  Bing Wang; Steve Valentine; Manolo Plasencia; Sriram Raghuraman; Xiang Zhang
Journal:  BMC Bioinformatics       Date:  2010-04-11       Impact factor: 3.169

9.  Ultrafast differential ion mobility spectrometry at extreme electric fields coupled to mass spectrometry.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith; Martin Holden; Martyn Rush; Andrew Thompson; Danielle Toutoungi
Journal:  Anal Chem       Date:  2009-10-01       Impact factor: 6.986

10.  A Structures for Lossless Ion Manipulations (SLIM) Module for Collision Induced Dissociation.

Authors:  Ian K Webb; Sandilya V B Garimella; Randolph V Norheim; Erin S Baker; Yehia M Ibrahim; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2016-04-20       Impact factor: 3.109

View more