A fully 3-D reconstruction algorithm has been developed to reconstruct data from a 16 ring PET camera (a Siemens/CTI 953B) with automatically retractable septa. The tomograph is able to acquire coincidences between any pair of detector rings and septa retraction increases the total system count rate by a factor of 7.8 (including scatter) and 4.7 (scatter subtracted) for a uniform, 20 cm diameter cylinder. The reconstruction algorithm is based on 3-D filtered backprojection, expressed in a form suitable for the multi-angle sinogram data. Sinograms which are not measured due to the truncated cylindrical geometry of the tomograph, but which are required for a spatially invariant response function, are obtained by forward projection. After filtering, the complete set of sinograms is backprojected into a 3-D volume of 128x128x31 voxels using a voxel-driven procedure. The algorithm has been validated with simulation, and tested with both phantom and clinical data from the 953B.

Year:  1991        PMID: 18222855     DOI: 10.1109/42.108584

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  12 in total

Review 1.  3D acquisition and reconstruction in positron emission tomography.

Authors:  D L Bailey
Journal:  Ann Nucl Med       Date:  1992-08       Impact factor: 2.668

2.  A method for measuring the absolute sensitivity of positron emission tomographic scanners.

Authors:  D L Bailey; T Jones; T J Spinks
Journal:  Eur J Nucl Med       Date:  1991

3.  Brain activity related to serial cognitive performance resembles circuitry of higher order motor control.

Authors:  B M de Jong; A H van Zomeren; A T Willemsen; A M Paans
Journal:  Exp Brain Res       Date:  1996-04       Impact factor: 1.972

4.  The sensory guidance of movement: a comparison of the cerebellum and basal ganglia.

Authors:  M Jueptner; I H Jenkins; D J Brooks; R S Frackowiak; R E Passingham
Journal:  Exp Brain Res       Date:  1996-12       Impact factor: 1.972

5.  Validation of 18F-FDG-PET Single-Subject Optimized SPM Procedure with Different PET Scanners.

Authors:  Luca Presotto; Tommaso Ballarini; Silvia Paola Caminiti; Valentino Bettinardi; Luigi Gianolli; Daniela Perani
Journal:  Neuroinformatics       Date:  2017-04

6.  Human cortical processing of colour and pattern.

Authors:  N A Barrett; M M Large; G L Smith; P T Michie; F Karayanidis; D J Kavanagh; R Fawdry; D Henderson; B T O'Sullivan
Journal:  Hum Brain Mapp       Date:  2001-08       Impact factor: 5.038

7.  Identification of the central vestibular projections in man: a positron emission tomography activation study.

Authors:  G Bottini; R Sterzi; E Paulesu; G Vallar; S F Cappa; F Erminio; R E Passingham; C D Frith; R S Frackowiak
Journal:  Exp Brain Res       Date:  1994       Impact factor: 1.972

8.  Performance comparison of a state-of-the-art neuro-SPET scanner and a dedicated neuro-PET scanner.

Authors:  D L Bailey; F Zito; M C Gilardi; A R Savi; F Fazio; T Jones
Journal:  Eur J Nucl Med       Date:  1994-05

9.  Cerebral representation of one's own past: neural networks involved in autobiographical memory.

Authors:  G R Fink; H J Markowitsch; M Reinkemeier; T Bruckbauer; J Kessler; W D Heiss
Journal:  J Neurosci       Date:  1996-07-01       Impact factor: 6.167

10.  Image reconstruction for PET/CT scanners: past achievements and future challenges.

Authors:  Shan Tong; Adam M Alessio; Paul E Kinahan
Journal:  Imaging Med       Date:  2010-10-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.