Reducing negativity artifacts in emission tomography: post-processing filtered backprojection solutions.

F O'Sullivan1, Y Pawitan, D Haynor.   

Abstract

The problem of negative artifacts in emission tomography reconstructions computed by filtered backprojection (FBP) is of practical concern particularly in low count studies. Statistical reconstruction methods based on maximum likelihood (ML) are automatically constrained to be non-negative but their excessive computational overhead (orders of magnitude greater than FBP) has limited their use in operational settings. Motivated by the statistical character of the negativity artifact, the authors develop a simple post-processing technique that iteratively adjusts negative values by cancellation with positive values in a surrounding local neighborhood. The compute time of this approach is roughly equivalent to 2 applications of FBP. The approach was evaluated by numerical simulation in 1- and 2-dimensional (2D) settings. In 2D, the source distributions included the Hoffman, the Shepp and Vardi, and a digitized version of the Jaszczak cold spheres phantoms. The authors' studies compared smoothed versions of FBP, the post-processed FBP, and ML implemented by the expectation-maximization algorithm. The root mean square (RMS) error between the true and estimated source distribution was used to evaluate performance; in 2D, additional region-of-interest-based measures of reconstruction accuracy were also employed. In making comparisons between the different methods, the amount of smoothing applied to each reconstruction method was adapted to minimize the RMS error-this was found to be critical.

Entities:  

Year:  1993        PMID: 18218459     DOI: 10.1109/42.251115

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Comparison of a noise-weighted filtered backprojection algorithm with the Standard MLEM algorithm for poisson noise.

Authors:  Gengsheng L Zeng
Journal:  J Nucl Med Technol       Date:  2013-10-24

2.  Development and evaluation of a prototype detector for an intraoperative laparoscopic coincidence imaging system with PET tracers.

Authors:  Madhushanka R Liyanaarachchi; Kenji Shimazoe; Hiroyuki Takahashi; Keiichi Nakagawa; Etsuko Kobayashi; Ichiro Sakuma
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-11-07       Impact factor: 2.924

3.  Efficient Bandwidth Estimation in 2D Filtered Backprojection Reconstruction.

Authors:  Ranjan Maitra
Journal:  IEEE Trans Image Process       Date:  2019-06-04       Impact factor: 10.856

4.  Filtered Backprojection Algorithm Can Outperform Iterative Maximum Likelihood Expectation-Maximization Algorithm.

Authors:  Gengsheng L Zeng
Journal:  Int J Imaging Syst Technol       Date:  2012-05-12       Impact factor: 2.000

5.  Non-destructive 3D imaging method using muonic X-rays and a CdTe double-sided strip detector.

Authors:  I-Huan Chiu; Shin'ichiro Takeda; Meito Kajino; Atsushi Shinohara; Miho Katsuragawa; Shunsaku Nagasawa; Ryota Tomaru; Goro Yabu; Tadayuki Takahashi; Shin Watanabe; Soshi Takeshita; Yasuhiro Miyake; Kazuhiko Ninomiya
Journal:  Sci Rep       Date:  2022-03-28       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.