Literature DB >> 18212731

Functional hemodynamic monitoring and dynamic indices of fluid responsiveness.

F Cavallaro1, C Sandroni, M Antonelli.   

Abstract

Knowing whether or not a fluid infusion can improve cardiac output (fluid responsiveness) is crucial when treating hemodynamically unstable patients. Generally, cardiac filling pressures (central venous pressure, pulmonary artery occlusion [''wedge''] pressure) and volumes (end-diastolic left and right ventricular volume) are used, although they are not reliable predictors of fluid responsiveness. For this reason, new indices, the so-called dynamic indices of fluid responsiveness, have been recently introduced in clinical use. If stroke volume, or stroke volume-derived parameters (pulse pressure and aortic flow) show wide variation during mechanical ventilation, a good response to fluid therapy can be predicted. As these indices are based upon the effects of controlled mechanical ventilation on stroke volume, they can be used in deeply sedated or apneic patients whose cardiac rhythm is regular. To overcome these limitations, new dynamic indices have been introduced. Among them, variation of cardiac output induced by passive leg raising (PLR) has raised particular interest since it can identify fluid responders even among spontaneously breathing and non-sinus rhythm patients. Although promising, the dynamic indices of fluid responsiveness have been studied only retrospectively in a relatively small number of patients and evidence that clinical use of these indices can improve outcome is still limited. Further investigations are needed to confirm their clinical validity.

Entities:  

Mesh:

Year:  2008        PMID: 18212731

Source DB:  PubMed          Journal:  Minerva Anestesiol        ISSN: 0375-9393            Impact factor:   3.051


  25 in total

1.  Assessment of cardiac preload status by pulse pressure variation in patients after anesthesia induction: comparison with central venous pressure and initial distribution volume of glucose.

Authors:  Zhiyong He; Hui Qiao; Wei Zhou; Yun Wang; Zhendong Xu; Xuehua Che; Jun Zhang; Weimin Liang
Journal:  J Anesth       Date:  2011-09-21       Impact factor: 2.078

Review 2.  Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis.

Authors:  Claudio Sandroni; Fabio Cavallaro; Cristina Marano; Chiara Falcone; Paolo De Santis; Massimo Antonelli
Journal:  Intensive Care Med       Date:  2012-06-26       Impact factor: 17.440

Review 3.  Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies.

Authors:  Fabio Cavallaro; Claudio Sandroni; Cristina Marano; Giuseppe La Torre; Alice Mannocci; Chiara De Waure; Giuseppe Bello; Riccardo Maviglia; Massimo Antonelli
Journal:  Intensive Care Med       Date:  2010-05-26       Impact factor: 17.440

4.  Prediction of volume responsiveness using pleth variability index in patients undergoing cardiac surgery after cardiopulmonary bypass.

Authors:  Sebastian Haas; Constantin Trepte; Martin Hinteregger; Rebecca Fahje; Bjoern Sill; Lena Herich; Daniel A Reuter
Journal:  J Anesth       Date:  2012-05-16       Impact factor: 2.078

5.  Pulse and systolic pressure variation assessment in partially assisted ventilatory support.

Authors:  Matteo Zaniboni; Paolo Formenti; Michele Umbrello; Andrea Galimberti; Andrea Noto; Gaetano Iapichino
Journal:  J Clin Monit Comput       Date:  2008-10-09       Impact factor: 2.502

Review 6.  Clinician-performed ultrasound in hemodynamic and cardiac assessment: a synopsis of current indications and limitations.

Authors:  N Kelly; R Esteve; T J Papadimos; R P Sharpe; S A Keeney; R DeQuevedo; M Portner; D P Bahner; S P Stawicki
Journal:  Eur J Trauma Emerg Surg       Date:  2015-01-08       Impact factor: 3.693

Review 7.  Determinants of systemic venous return and the impact of positive pressure ventilation.

Authors:  David Berger; Jukka Takala
Journal:  Ann Transl Med       Date:  2018-09

8.  Evaluation of external reference levels for central venous pressure measurements of severely obese patients in the supine position.

Authors:  Kazuyuki Mizunoya; Hitoshi Saito; Yuji Morimoto
Journal:  J Anesth       Date:  2018-05-28       Impact factor: 2.078

9.  The passive leg raise test to predict fluid responsiveness in children--preliminary observations.

Authors:  Guo-ping Lu; Gangfeng Yan; Yang Chen; Zhu-jin Lu; Lin-en Zhang; Niranjan Kissoon
Journal:  Indian J Pediatr       Date:  2013-12-11       Impact factor: 1.967

Review 10.  Clinical review: practical recommendations on the management of perioperative heart failure in cardiac surgery.

Authors:  Alexandre Mebazaa; Antonis A Pitsis; Alain Rudiger; Wolfgang Toller; Dan Longrois; Sven-Erik Ricksten; Ilona Bobek; Stefan De Hert; Georg Wieselthaler; Uwe Schirmer; Ludwig K von Segesser; Michael Sander; Don Poldermans; Marco Ranucci; Peter C J Karpati; Patrick Wouters; Manfred Seeberger; Edith R Schmid; Walter Weder; Ferenc Follath
Journal:  Crit Care       Date:  2010-04-28       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.