| Literature DB >> 18211682 |
Günter Kampf1, Angela Hollingsworth.
Abstract
BACKGROUND: Some studies indicate that the commonly recommended 30 s application time for the post contamination treatment of hands may not be necessary as the same effect may be achieved with some formulations in a shorter application time such as 15 s.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18211682 PMCID: PMC2259358 DOI: 10.1186/1476-0711-7-2
Source DB: PubMed Journal: Ann Clin Microbiol Antimicrob ISSN: 1476-0711 Impact factor: 3.944
Activity of Sterillium® Comfort Gel against 11 Gram-positive ATCC strains and clinical isolates (15 s exposure time).
| Bacterial species | Lowest RF (ATCC strain) | Lowest RF (clinical isolate) |
| 7.06 | 7.34 | |
| 7.29 | 6.90 | |
| 6.34 | 6.23 | |
| 5.48 | 5.38 | |
| 6.29 | 6.58 | |
| Staphylococcus epidermidis | 5.82 | 5.60 |
| 5.34 | 6.16 | |
| 5.38 | 5.41 | |
| 6.60 | 5.41 | |
| 5.34 | 5.60 | |
| 6.14 | 5.48 |
Experiments were done according to the US tentative final monograph; presentation of the lowest reduction factor (RF) of four replicate experiments for each test strain.
Activity of Sterillium® Comfort Gel against 16 Gram-negative ATCC strains and clinical isolates (15 s exposure time).
| Bacterial species | Lowest RF (ATCC strain) | Lowest RF (clinical isolate) |
| 6.60 | 5.34* | |
| 6.86 | 5.34* | |
| 6.72 | 6.58 | |
| 6.48 | 5.48 | |
| 6.83 | 5.91 | |
| 6.45 | 6.75 | |
| 6.64 | 6.72 | |
| 5.86 | 5.34 | |
| 6.53 | 6.62 | |
| 6.73 | 6.62 | |
| 6.78 | 6.68 | |
| 6.56 | 6.73 | |
| 6.79 | 6.75 | |
| 6.72 | 6.68 | |
| 6.87 | 5.62 | |
| 6.28 | 6.41 |
Experiments were done according to the US tentative final monograph; presentation of the lowest reduction factor (RF) of four replicate experiments for each test strain; *a clinical isolate was obtained as Acinetobacter calcoaceticus var lwoffi.
Activity of Sterillium® Comfort Gel against 11 emerging bacterial pathogens (15 s exposure time).
| Bacterial species | Lowest RF |
| 6.45 | |
| 5.34 | |
| 7.15 | |
| 6.70 | |
| 6.48 | |
| 6.58 | |
| 6.45 | |
| 7.22 | |
| 6.38 | |
| 6.70 | |
| 5.38 |
Experiments were performed according to the US tentative final monograph; presentation of the lowest reduction factor (RF) of four replicate experiments for each test strain.