Literature DB >> 18207662

Comparison of target registration errors for multiple image-guided techniques in accelerated partial breast irradiation.

David P Gierga1, Marco Riboldi, Julie C Turcotte, Greg C Sharp, Steve B Jiang, Alphonse G Taghian, George T Y Chen.   

Abstract

PURPOSE: External beam accelerated partial breast irradiation requires accurate localization of the target volume for each treatment fraction. Using the concept of target registration error (TRE), the performance of several methods of target localization was compared. METHODS AND MATERIALS: Twelve patients who underwent external beam accelerated partial breast irradiation were included in this study. TRE was quantified for four methods of image guidance: standard laser-based setup, kilovoltage imaging of the chest wall, kilovoltage imaging of surgically implanted clips, and three-dimensional surface imaging of the breast. The use of a reference surface created from a free-breathing computed tomography scan and a reference surface directly captured with three-dimensional video imaging were compared. The effects of respiratory motion were also considered, and gating was used for 8 of 12 patients.
RESULTS: The median value of the TRE for the laser, chest wall, and clip alignment was 7.1 mm (n=94), 5.4 mm (n=81), and 2.4 mm (n=93), respectively. The median TRE for gated surface imaging based on the first fraction reference surface was 3.2 mm (n=49), and the TRE for gated surface imaging using the computed tomography-based reference surface was 4.9 mm (n=56). The TRE for nongated surface imaging using the first fraction reference surface was 6.2 mm (n=25).
CONCLUSIONS: The TRE of surface imaging using a reference surface directly captured with three-dimensional video and the TRE for clip-based setup were within 1 mm. Gated capture is important for surface imaging to reduce the effects of respiratory motion in accelerated partial breast irradiation.

Entities:  

Mesh:

Year:  2008        PMID: 18207662     DOI: 10.1016/j.ijrobp.2007.11.020

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  28 in total

Review 1.  A review of image-guided radiotherapy.

Authors:  George T Y Chen; Gregory C Sharp; Shinichiro Mori
Journal:  Radiol Phys Technol       Date:  2008-12-16

Review 2.  Image guidance in proton therapy for lung cancer.

Authors:  Miao Zhang; Wei Zou; Boon-Keng Kevin Teo
Journal:  Transl Lung Cancer Res       Date:  2018-04

3.  Initial validation and clinical experience with 3D optical-surface-guided whole breast irradiation of breast cancer.

Authors:  S Li; T DeWeese; B Movsas; Dezhi Liu; Deborah Frassica; Jinkoo Kim; Qing Chen; Eleanor Walker
Journal:  Technol Cancer Res Treat       Date:  2012-02

4.  Three-dimensional surface scanning for accurate patient positioning and monitoring during breast cancer radiotherapy.

Authors:  C Gaisberger; P Steininger; B Mitterlechner; S Huber; H Weichenberger; F Sedlmayer; H Deutschmann
Journal:  Strahlenther Onkol       Date:  2013-06-07       Impact factor: 3.621

5.  An image-guided study of setup reproducibility of postmastectomy breast cancer patients treated with inverse-planned intensity modulated radiation therapy.

Authors:  Christine H Feng; Emily Gerry; Steven J Chmura; Yasmin Hasan; Hania A Al-Hallaq
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-10-22       Impact factor: 7.038

6.  Residual image registration error by fiducial markers in accelerated partial breast irradiation using C-arm linac: a phantom study.

Authors:  Ryohei Yamauchi; Natsuki Murayoshi; Shinobu Akiyama; Norifumi Mizuno; Tomoyuki Masuda; Tomoko Itazawa; Jiro Kawamori
Journal:  Phys Eng Sci Med       Date:  2022-06-03

7.  Target registration errors with surface imaging system in conformal radiotherapy for prostate cancer: study on 19 patients.

Authors:  S Bartoncini; C Fiandra; M G Ruo Redda; S Allis; F Munoz; U Ricardi
Journal:  Radiol Med       Date:  2012-05-14       Impact factor: 3.469

8.  Detection of setup uncertainties with 3D surface registration system for conformal radiotherapy of breast cancer.

Authors:  Letizia Deantonio; Laura Masini; Gianfranco Loi; Giuseppina Gambaro; Cesare Bolchini; Marco Krengli
Journal:  Rep Pract Oncol Radiother       Date:  2011-04-08

9.  Intra-fraction setup variability: IR optical localization vs. X-ray imaging in a hypofractionated patient population.

Authors:  Maria Francesca Spadea; Barbara Tagaste; Marco Riboldi; Eleonora Preve; Daniela Alterio; Gaia Piperno; Cristina Garibaldi; Roberto Orecchia; Antonio Pedotti; Guido Baroni
Journal:  Radiat Oncol       Date:  2011-04-15       Impact factor: 3.481

10.  Optimization of Adjuvant Radiation in Breast Conservation Therapy: Can We Minimize without Compromise?

Authors:  Sophia M Edwards-Bennett; Candace R Correa; Eleanor E Harris
Journal:  Int J Breast Cancer       Date:  2011-10-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.