Quantitative comparison of five current protocols in gait analysis.

Alberto Ferrari1, Maria Grazia Benedetti, Esteban Pavan, Carlo Frigo, Dario Bettinelli, Marco Rabuffetti, Paolo Crenna, Alberto Leardini.   

Abstract

Data collection and reduction procedures, coherently structured in protocols, are necessary in gait analysis to make kinematic and kinetic measurements clinically comprehensible. The current protocols differ considerably for the marker-set and for the biomechanical model implemented. Nevertheless, conventional gait variables are compared without full awareness of these differences. A comparison was made of five worldwide representative protocols by analysing kinematics and kinetics of the trunk, pelvis and lower limbs exactly over the same gait cycles. A single comprehensive arrangement of markers was defined by merging the corresponding five marker-sets. This resulted in 60 markers to be positioned either on the skin or on wands, and in 16 anatomical landmark calibrations to be performed with an instrumented pointer. Two healthy subjects and one patient who had a special two degrees of freedom knee prosthesis implanted were analysed. Data from up-right posture and at least three gait repetitions were collected. Five corresponding experts participated in the data collection and analysed independently the data according to their own procedures. All five protocols showed good intra-protocol repeatability. Joint flexion/extension showed good correlations and a small bias among protocols. Out-of-sagittal plane rotations revealed worse correlations, and in particular knee abduction/adduction had opposite trends. Joint moments compared well, despite the very different methods implemented. The abduction/adduction at the prosthetic knee, which was fully restrained, revealed an erroneous rotation as large as 30 degrees in one protocol. Higher correlations were observed between the protocols with similar biomechanical models, whereas little influence seems to be ascribed to the marker-set.

Entities:  

Mesh:

Year:  2008        PMID: 18206374     DOI: 10.1016/j.gaitpost.2007.11.009

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  49 in total

1.  Repeatability of electromyography recordings and muscle synergies during gait among children with cerebral palsy.

Authors:  Katherine M Steele; Meghan E Munger; Keshia M Peters; Benjamin R Shuman; Michael H Schwartz
Journal:  Gait Posture       Date:  2018-10-22       Impact factor: 2.840

2.  First in vivo assessment of "Outwalk": a novel protocol for clinical gait analysis based on inertial and magnetic sensors.

Authors:  Alberto Ferrari; Andrea Giovanni Cutti; Pietro Garofalo; Michele Raggi; Monique Heijboer; Angelo Cappello; Angelo Davalli
Journal:  Med Biol Eng Comput       Date:  2009-11-13       Impact factor: 2.602

Review 3.  Biomechanical techniques to evaluate tibial rotation. A systematic review.

Authors:  Mak-Ham Lam; Daniel Tik-Pui Fong; Patrick Shu-Hang Yung; Kai-Ming Chan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-13       Impact factor: 4.342

4.  Effect of a single session of transcranial direct-current stimulation on balance and spatiotemporal gait variables in children with cerebral palsy: A randomized sham-controlled study.

Authors:  Luanda A C Grecco; Natália A C Duarte; Nelci Zanon; Manuela Galli; Felipe Fregni; Claudia S Oliveira
Journal:  Braz J Phys Ther       Date:  2014-10-10       Impact factor: 3.377

5.  Neck range of motion measurements using a new three-dimensional motion analysis system: validity and repeatability.

Authors:  Haruhi Inokuchi; Michio Tojima; Hiroshi Mano; Yuki Ishikawa; Naoshi Ogata; Nobuhiko Haga
Journal:  Eur Spine J       Date:  2015-04-07       Impact factor: 3.134

6.  Compact tracking of surgical instruments through structured markers.

Authors:  N Alberto Borghese; I Frosio
Journal:  Med Biol Eng Comput       Date:  2013-03-10       Impact factor: 2.602

7.  Alterations in walking knee joint stiffness in individuals with knee osteoarthritis and self-reported knee instability.

Authors:  Jonathan A Gustafson; Shannon Gorman; G Kelley Fitzgerald; Shawn Farrokhi
Journal:  Gait Posture       Date:  2015-10-08       Impact factor: 2.840

8.  No difference in gait between posterior cruciate retention and the posterior stabilized design after total knee arthroplasty.

Authors:  Lennard G H van den Boom; Jan P K Halbertsma; Jos J A M van Raaij; Reinoud W Brouwer; Sjoerd K Bulstra; Inge van den Akker-Scheek
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-07       Impact factor: 4.342

9.  Shoulder biomechanics and the success of translational research.

Authors:  Andrea Giovanni Cutti; Edward K Chadwick
Journal:  Med Biol Eng Comput       Date:  2014-03       Impact factor: 2.602

10.  Gait analysis in children with cerebral palsy via inertial and magnetic sensors.

Authors:  Josien C van den Noort; Alberto Ferrari; Andrea G Cutti; Jules G Becher; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2012-12-09       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.